16
78-8140-2401-0-B
11.0 Cable Strength Member Installation For Armored Central Tube Cable
11.1 Please refer to 4460-D/FO-SS instruction manual, 78-8128-0289-6
(3M
™
Scotchlok
™
Shield Bond
Connector Assembly 4460-D/FO and 4460-D/FO-SS)
for shield bond installation.
12.0 3M
™
Double Cable Entry Port ECAM-27MM-D Installation
12.1 Lightly lubricate the oval gasket using the
supplied silicone lubricant before installing
the gasket into the groove in the base of the
3M
™
Fiber Dome.
Note: Follow health, safety and environmental
information. Refer to product label or Material
Safety Data sheet for silicone lubricant.
12.2 Feed cable through oval port
CAUTION
Do not kink fiber. Handling small groups of
buffer tubes reduces chances of kinking.
12.3 Position the 3M
™
Double Cable Entry Port ECAM-27MM-D assembly with CSM bracket facing down.
Correct
Incorrect