background image

Installing the NEMA 4X Panel Gasket

ET 350/355 Monitors and ET 3250/3255 Computers

Equipment

Materials supplied

The following materials are provided for installing 
the NEMA 4X panel gasket:

!

12 Phillips #10-32 by 3/4" screws

!

12 Phillips #10-32 by 1/2" screws

!

12 flat washers

!

12 lock washers

!

1 gasket

Tools required

!

Phillips No. 2 torque screwdriver

Mounting using the NEMA 4X panel 

gasket

1.

Use the gasket as a template to position the 
cutout. Tack or tape the gasket onto the panel 
where you want to mount the unit.

2.

Mark the position and dimensions of the cutout 
and screw holes on the panel. Cutout dimensions 
are:

!

Width: 14.36 inches (364.74 mm)

!

Height: 12.33 inches (313.18 mm)

Intended Use

When properly installed using the materials provided, and 
according to these instructions, the NEMA 4X panel gasket 
is intended to provide for ET 350/355 monitors and for 
ET 3250/3255 computers a NEMA 4X/IP66 seal between 
the panel and the ET unit.

Warning

Read and understand all safety information 
before installing and using this product.
To reduce the risk of electric shock or fire 
which could result in serious personal injury or 
death:

!

Follow all product and accessory installation 
instructions.

!

Any servicing or other procedures not described in 
this document are to be performed only by 3M Touch 
Systems service personnel.

!

Properly install the monitor or computer with a 
NEMA 4X gasket that is undamaged and effective.

!

Wiring installation should be done by a journeyman 
electrician and must comply with federal and local 
electrical codes.

To reduce the risk of electric shock which 
could result in serious personal injury or death:

!

Install the NEMA 4X panel gasket properly in order to 
achieve a NEMA 4X seal on the front bezel.

Caution

To reduce the risk of fire which may result in minor 
or moderate injury or cause property damage:

!

Provide a minimum of 1 inch (25.4 mm) clearance 
behind the ET unit for proper air circulation. In warm 
working environments, this depth should be increased 
to provide better air circulation.

Summary of Contents for Dynapro ET 355 Monitor HL

Page 1: ...n the panel and the ET unit Warning Read and understand all safety information before installing and using this product To reduce the risk of electric shock or fire which could result in serious personal injury or death Follow all product and accessory installation instructions Any servicing or other procedures not described in this document are to be performed only by 3M Touch Systems service per...

Page 2: ... skip to steps 10 and 11 then come back to step 6 6 Place the ET unit in the cutout You may need assistance at this point to hold the unit in place 7 Attach the unit to the panel from the back using the 10 32 screws that are supplied Choose the 1 2 or 3 4 screws supplied whichever is best for the thickness of your panel Put a lock washer on each screw and then put a flat washer on each screw on to...

Page 3: ...cations are subject to change without notice 3M Touch Systems Products are warranted to meet their published specifications from the date of shipment and for the period stated in the specification 3M Touch Systems makes no additional warranties express or implied including but not limited to any implied warranties of merchantability or fitness for a particular purpose User is responsible for deter...

Page 4: ...ew Westminster BC Canada V3M 6L3 www 3Mtouch com For more information on 3M touch products visit 3Mtouch com or call toll free 1 800 667 0374 Worldwide Manufacturing Plants Austin Texas Methuen Massachusetts Milwaukee Wisconsin Vancouver BC Canada Abingdon UK 3M 2002 11723 Rev 1 2 ...

Reviews: