3M Dynapro ET 350 Monitor User’s Installation Guide
64
Serial port
RS-232C connector
Pin
Signal
Description
In/Out
1
DCD
N.C.*
2
RXD
Receive Data
OUT
3
TXD
Transmit Data
IN
4
DTR
Data Terminal
Ready
IN
5
SGND
Signal Ground
---
6
DSR
N.C.*
7
RTS
N.C.*
8
CTS
N.C.*
9
RI
N.C.*
Important: To reduce the risk of voiding FCC and CE compliance and reducing
the performance of the ET 350 monitor, when making your own cable, reduce
the sensitivity of the ET 350 monitor to electrical and radio frequency noise by
connecting the cable shield to the connector shield (360 degree shield) on both
ends of the cable.
*N.C. = No Connection