3M

 Powered & Supplied Air Respirators

Care and Maintenance

Before Use

  Ensure Battery is fully charged

  Check airflow – Insert airflow indicator into Turbo outlet, 

turn on, if ball fails to rise above line change the filter and 
re-check airflow

  Ensure Gasket is replaced every time filter is changed

  Inspect Breathing Tube – ensure it is free from splits or 

holes. Replace if necessary

  Inspect Belt – ensure it is free from splits or tears and the 

buckle is undamaged

Monthly

  Carry out all the ‘Before Use’ inspections and create 

record of this monthly check for the turbo

Additional Checks

  Listen for unusual motor noise. Replace blower unit if 

necessary

After Use

  Clean casing with cloth dampened with a mild 

solution of water and liquid household soap

  Disinfect with 3M

 105 Wipes

  Charge Battery

  Store in a dry, clean area / locker away from direct 

sunlight, high temperatures and solvents

Replace all damaged paRts immediately to 
ensuRe coRRect levels of pRotection

To maintain protection levels, optimise the effective lifetime of the system and avoid the additional 
cost of replacement, it is extremely important to carry out regular checks and maintenance on 
Powered and Supplied Air Respirators.

3M

 Dustmaster

 

 

Powered Air Turbo Unit 

The powered air turbo for protection against dusts, welding fumes and nuisance odours.