7-1
ITEM
CWS100ME
CWS100MEJ
CWS100MECJ
CWS150ME
CWS150MEJ
CWS150MECJ
CWS200ME
CWS200MEJ
CWS200MECJ
CWS300ME
CWS300MEJ
CWS300MECJ
Nominal Media Volume, Ft
3
1.0
1.5
2.0
3.0
Salt Dosage, Lbs.
Salt Effi cient Setting
4
6
8
18
Factory Setting
6
9
12
18
Maximum Setting
16
16
24
45*
Softening Capacity, grains
At Salt Effi cient Setting
16,300
24,200
34,100
67,600
At Factory Salt Setting
21,600
32,000
45,000
67,600
At Maximum Salt Setting
29,000
43,000
56,800
87,800
Salt Effi ciency, grains per lb. of salt
At Salt Effi cient Setting
4,078
4,026
4,260
3.753
Flow Rates
Continuous (no duration limit)
4.0
6.0
7.0
9.0
At 15 psi Pressure Loss
11.0
14.3
13.5
18.5
Pressure Loss, psi
At Continuous Flow
4
5
5
4
Regeneration Flow Rates, gpm
Backwash
1.7
2.7
2.7
5.3
Brine Draw @ 50 psi
0.18
0.26
0.26
0.45
Slow Rinse @ 50 psi
0.27
0.34
0.36
0.71
Rapid Rinse
1.7
2.7
2.7
5.3
Brine Refi ll
0.5
0.5
0.5
0.5
Approximate Water Used (at Factory Setting)
44
77
78
148
Regeneration Duration, minutes a (at Factory Setting)
1st Backwash
6
6
6
6
Brine Draw/Rinse
45
45
45
45
2nd Backwash
3
3
3
3
Rapid Rinse
3
3
3
3
Brine Refi ll
3’ 51”
3’ 51”
7’ 52”
7’ 52”
Approximate Total Time
61
63
65
69
Inlet/Outlet Size
1” NPT
1” NPT
1” NPT
1” NPT
Mineral Tank Dia. x Ht., in.
8 x 44
10 x 44
10 x 54
14 x 65
Overall D & H w/Valve, in.
Width (Including Brine Tank)
33
35
35
42
Depth
15
15
15
18
Height (Including Valve)
53
53
63
74
Brine Tank, W x D x H, in.
15 x 15 x 34
15 x 15 x 34
15 x 15 x 34
18 x 33
Salt settings below 6# require removal of the salt grid
Salt settings above 24# require optional 18 x 33 brine tank
*Salt settings above 35# require optional 24 x 50 brine tank
Brine Tank Capacity
With Salt Grid Leg Extensions
180
180
180
300
With Salt Grid Leg Extensions
(required on salt settings above 18 #)
NA
135
135
300
Approximate Shipping Wt.
97
125
154
244
These softeners conform to NSF/ANSI Standard 44 for specifi c performance claims. When set at the Salt Effi cient setting, these softeners meet or exceed Std. 44 requirement for salt effi ciency. Effi ciency claim is only
valid at the Salt Effi cient Setting.
NOTES: For satisfactory performance, indicated fl ow rates and duration should not be exceeded. Flow rates specifi ed are adequate for normal residential applications. Do not use Service Flow Rate if treated water is to
supply a geothermal heat pump, swimming pool, etc. (contact our Customer Service Department at 1-866-990-9785 before selecting equipment). Service fl ow rates have been tested against NSF Standard 44.
SECTION 7: SPECIFICATIONS AND OPERATING DATA