Important notice

The use of the 3M product described within this document assumes that the user has previous experience of this type of product and 

that it will be used by a competent professional. Before any use of this product it is recommended to complete some trials to validate 

the performance of the product within its expected application.
All information and specification details contained within this document are inherent to this specific 3M product and would not be applied 

to other products or environment. Any action or usage of this product made in violation of this document is at the risk of the user.
Compliance to the information and specification relative to the 3M product contained within this document does not exempt the user from 

compliance with additional guidelines (safety rules, procedures). 
Compliance to operational requirements especially in respect to the environment and usage of tools with this product must be observed. 

The 3M group (which cannot verify or control those elements) would not be held responsible for the consequences of any violation of these 

rules which remain external to its decision and control.
Warranty conditions for 3M products are determined with the sales contract documents and with the mandatory and applicable clause, 

excluding any other warranty or compensation.

3M

 Personal Safety Division 

|

 3M

 Aura

 Particulate Respirators 9300+Gen3 Series

Fit check 

1.  Cover the front of the respirator with both hands 

being careful not to disturb the fit of the respirator.

2a. UNVALVED respirator – EXHALE sharply.
2b. VALVED respirator – INHALE sharply.
3.  If air leaks around the nose, re-adjust the noseclip 

to eliminate leakage. Repeat the above fit check.

4.  If air leaks at the respirator edges, work the straps 

back along the sides of the head to eliminate leakage. 

Repeat the above fit check.

If you CANNOT achieve a proper fit DO NOT enter 

the hazardous area. See your supervisor.
Users should be fit tested in accordance with 

national requirements.
For information regarding fit testing procedures, 

please contact 3M.

Disposal

Contaminated products should be disposed as hazardous 

waste in accordance with national regulations.

Marking

  NR =

  

Non reusable

  D =

  

Meets the clogging requirements

  

 

End of Shelf Life. Date format: YYYY/MM/DD

 

Temperature Range

 

Maximum Relative Humidity

 

Name and address of Legal Manufacturer

 

Dispose of in accordance with local regulations

Approvals

These products are CE Marked to the requirements 

of Community Directive 89/686/EEC or European Regulation 

(EU) 2016/425. The applicable legislation can be determined 

by reviewing the Certificate and Declaration of Conformity 

at http://www.3M.com/Respiratory/certs
These products are type approved and audited annually 

by BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton 

Keynes MK5 8PP, UK, Notified Body No. 0086.
Made in UK, in an ISO 9001:2008, ISO 14001:2004 

and OHSAS 18001:2007 certified plant.

Summary of Contents for Aura 9310+Gen3

Page 1: ...eakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in this standard include filter penetration extended exposure loading test flammability breathing resistance and total inward leakage Reusable products are also subjected to cleaning storage and mandatory clogging resistance tests clogging is optional for non reusable products A full copy of EN 149 20...

Page 2: ...limits EN 149 2001 A1 2009 classification Maximum Breathing Resistance Inhalation at 30l min Inhalation at 95l min Exhalation at 160l min FFP1 0 6 mbar 2 1 mbar 3 0 mbar FFP2 0 7 mbar 2 4 mbar 3 0 mbar FFP3 1 0 mbar 3 0 mbar 3 0 mbar Clogging For single shift use respirators NR the clogging test is optional For re usable respirators R this test is mandatory The respirators are loaded with very hig...

Page 3: ...r own limits on oxygen deficiency Seek advice if in doubt Do not use for respiratory protection against atmospheric contaminants concentrations which are unknown or immediately dangerous to life and health IDLH Do not use with beards or other facial hair that may inhibit contact between the face and the product thus preventing a good seal Leave the contaminated area immediately if Ŕ Ŕ Breathing be...

Page 4: ...th the sales contract documents and with the mandatory and applicable clause excluding any other warranty or compensation 3M Personal Safety Division 3M Aura Particulate Respirators 9300 Gen3 Series Fit check 1 Cover the front of the respirator with both hands being careful not to disturb the fit of the respirator 2a UNVALVED respirator EXHALE sharply 2b VALVED respirator INHALE sharply 3 If air l...

Reviews: