background image

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution

of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business

relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components

to meet their specific needs.

With the principle of “Quality Parts,Customers Priority,Honest Operation,and Considerate Service”,our business

mainly focus on the distribution of electronic components. Line cards we deal with include

Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise

IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,

and automotives areas.

We are looking forward to setting up business relationship with you and hope to provide you with the best service

and solution. Let us make a better world for our industry!

Contact us

Tel: +86-755-8981 8866 Fax: +86-755-8427 6832

Email & Skype: [email protected] Web: www.chipsmall.com

Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China

 

 

Summary of Contents for 3M034-030-TNG

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...User s Guide 3M EM Aware TNG ESD Event Monitor Models 3M034 3 TNG 3M034 030 TNG and 3M034 031 TNG Including Starter Kits ...

Page 3: ...n Page Intended Use 3 Safety Statements 4 Package Contents 5 Installation and Mounting Instructions 5 Controlling the Monitor 7 Changing the ESD Event Parameters 8 Data Acquisition System 10 Regulatory Information 11 Warranty 14 ...

Page 4: ...ed as specified in this user s guide It is intended for use in the following environmental conditions only 1 Indoor use 2 Altitudes up to 2 000 meters above sea level 3 Temperature range of 10ºC to 40ºC 4 Maximum relative humidity of 80 for temperatures up to 31ºC decreasing linearly to 50 relative humidity at 40ºC 5 Pollution degree two office laboratory test station The monitor system has not be...

Page 5: ...hich if not avoided could result in death or serious injury Use only the power adapter provided with the product If power adapter is missing or damaged only replace with one supplied by 3M Safety Information Explanation of Signal Word Consequences WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury and or property damage CAUTION Indicate...

Page 6: ...se damage to the EM Aware TNG ESD Event Monitor and or to the FMS may occur NOTICE To reduce the risks associated with ground water contamination Never incinerate or dispose of product in a manner which is inconsistent with local state or federal regulations CAUTION Package Contents Check that the following items are included with the 3M EM Aware TNG ES Event Monitor Starter Kit shipping package E...

Page 7: ...tor center positive The EM Aware TNG ESD Event Monitor will light up with the display Shake the container above the antenna and the EM Aware TNG ESD Event Monitor should respond with beeps In an installation where power supply provides power to more than just EM Aware TNG monitors it is recommended to consider a separate power supply just for the network of EM Aware TNG units Antenna 3M EM Aware T...

Page 8: ...ed as L R U D and P in this user s guide The first level control takes place upon power up in which case all L R U D controls do the same function All of the directions scroll through the parameter displays as shown in Figure 3 At any of the parameters displayed the push of the joystick brings the next level control which allows you to change the parameter settings i e thresholds Power Input 12vDC...

Page 9: ...e Parameters 1 At the main screen display no REF symbol move the joystick until the display is as shown above 2 To reset the over threshold counter to zero press the joystick momentarily 3 To change the voltage range and thresholds push the joystick longer until a new screen appears The new screen shows a REF symbol at the right top corner 4 Move the joystick up or down to scroll on the voltage ra...

Page 10: ...until the screen shows the main static voltage screen Polarity Symbol Dot Level Graphics Voltage Seen V Time Seconds Threshold Status Threshold V Charge Threshold 3 0 seconds as shown Application note Measuring Ionization Observe the waveform in the third row Notice that the line is close to the zero level This would indicate a balanced condition A line that is above or below the zero level repres...

Page 11: ...he third is for ionization verification Please refer to the table below EM Aware Units Number of Units in a Kit RJ45 Jack Identification Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 ESD Events Channels 1 4 7 10 13 Change in Static Voltage 2 5 8 11 14 Ionizer Verification Channel 3 6 9 12 15 Smart Co efficient SCF The Smart Coefficient SCF feature works in conjunction with the change in voltage function Mode...

Page 12: ...less otherwise stated by 3M in writing this information represents 3M s best knowledge and belief based upon information provided by third party suppliers to 3M Name and Content of Hazardous Substances or Elements Part or Component Name Hazardous Substances or Elements Pb Hg Cd Cr VI PBB PBDE Termination in capacitor 0603 Solder in diode Finish in diode Terminations in PCBs Terminations in resisto...

Page 13: ...is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense NOTE Modifications to this ...

Page 14: ...3 du Canada cULus Statement Meets cULus requirements WEEE Statement The following information is only for EU members States The mark shown to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002 96 EC WEEE The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste but use the return and collection systems according to local law ...

Page 15: ...nts related to the product which are not contained in 3M s current publications or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for one year from the time of purchase 3M MAKES NO...