background image

For more information, please visit 3-form.com/Elements or call 800.726.0126

August 2021 | MAN-Rtg-400-47 | REV 005 © 2021 3form, Inc. All rights reserved.

Installation Manual

SimpleSpec 400.47

tm

Clario Cloud Circle

Summary of Contents for SimpleSpec 400.47

Page 1: ...r more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario Cloud Circle ...

Page 2: ...48 Clario Cloud 3 Wood Lag Screw with Eye Bolt 3 15 8895 3 Concrete Screw with Eye Bolt 3 15 8811 3 3 64 Ø 8 Cable with Hook 3 15 1677 3 3 Pre assembled 48 Clario Cloud Baffle 1 Eye Bolt Lag Bit 3 15 8812 1 Pre assembled 72 Clario Cloud Baffle 1 Eye Bolt Lag Bit 3 15 8812 1 Ring Gripper 3 15 1989 Ring Gripper 3 15 1989 2 For more information please visit 3 form com Elements or call 800 726 0126 Au...

Page 3: ...t 3 15 8811 Wood Lag Screw with Eye Bolt 3 15 8895 Pre assembled 48 Clario Cloud Baffle Ring Gripper 3 15 1989 3 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario Cloud Circle ...

Page 4: ...with Terminal End 3 15 1933 8 max cable to Sputnik 2438mm Unassembled 72 Clario Cloud Baffle Fins Cable length from Sputnik to Clario 4 maximum 30 recommended 20 minimum Ring Gripper 3 15 1989 4 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario Cloud Circle...

Page 5: ...vided here mark the pick points for your installation as needed Multiple templates may be helpful with a larger installation of clouds The pre installed Clario Cloud Hooks can be used with a laser level to help determine the best anchoring locations for the site conditions Ø48 14 5 48 48 Template 14 1 20 85 13 7 11 25 19 5 For more information please visit 3 form com Elements or call 800 726 0126 ...

Page 6: ...rough until Ring Gripper hits your mark a b Mark lengths of the cables depending on the chosen height using a permanent marker Hook Ring Gripper to the Clario Cloud Hooks attachment points on the cloud c 6 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario C...

Page 7: ...loud is level from all sides Make micro adjustments at each ring gripper if needed a b 7 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario Cloud Circle ...

Page 8: ...clouds See top diagram for location of where the cables attach to the 4 Point Sputniks above the Clario Cloud to determine mounting location For installations without Sputniks see lower diagram for hook locations 72 72 Template 20 85 Ø72 25 66 25 67 36 54 35 57 20 60 Ø72 35 52 25 67 25 73 36 48 Location where hooks are located 72 13 63 43 52 14 85 72 11 91 20 64 6 87 20 64 11 94 8 For more informa...

Page 9: ...4 Cable Length Perpendicular to Pattern Direction C 39 Cable Length Parallel to Pattern Direction 20 minimum 30 5 31 2 A C C B B Pattern Direction C C B B A Cable lengths are measured from the far end of the ring side of the Ring Gripper 3 15 1989 to where the cable enters the Sputnik 2 a 3 15 8895 or 3 15 8811 Install Cables and Eye Bolt into Mounting Surface b 3 1 5 1 6 7 7 9 For more informatio...

Page 10: ...through until Ring Gripper hits your mark a b Mark lengths of the cables depending on the chosen height using a permanent marker Hook Ring Gripper to the Clario Cloud Hooks attachment points on the cloud c 3 Assemble 4 Point Sputnik Hanging Anchor cont 10 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved...

Page 11: ...re cloud is level from all sides Make micro adjustments at each ring gripper if needed 11 For more information please visit 3 form com Elements or call 800 726 0126 August 2021 MAN RTG 400 47 REV 005 2021 3form Inc All rights reserved Installation Manual SimpleSpec 400 47 tm Clario Cloud Circle ...

Page 12: ...les Sound Absorption Test Results Material Sola Felt Sola Felt Sola Felt Noise Reduction Coefficient Alpha W Sound Absorption Average Test ASTM C423 09 0 75 0 70MH 0 77 Result Clario Cloud Modules have been independently tested and meet the criteria for approved interior finishes as described in the 2018 International Building Code Flammability and Smoke Test Results Building Code Approvals ASTM E...

Reviews: