background image

For more information, please visit 3-form.com or call 800.726.0126

November 2019 | mAN-rTG-200-08 | rev 003 © 2019 3form, Inc. All rights reserved.

SimpleSpec 200.08

tm

Installation Manual

ready To Go

Summary of Contents for SimpleSpec 200.08

Page 1: ...For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 2: ...2 M8 Thread Rod 25mm 3 15 1754 2 2 Cable Tensioner with Cover Plate KIT Stainless Steel 3 15 1636 K Black Oxide 3 15 2005 K Cable Tensioner with Cover Plate SS 3 15 1636 BO 3 15 2005 2 M8 Thread Rod 25mm 3 15 1754 2 1 3 8 Varia Panel 2 Suspend Anchoring KIT 3 15 7000 K M8 Threaded Wood Insert 3 15 0791 2 M8 Concrete Anchor 3 15 3011A 2 M8 Threaded Rod 50mm 3 15 3032A 2 M8 Thread Rod 25mm 3 15 1754...

Page 3: ...T SS 3 15 1636 K BO 3 15 2005 K 2 Suspend Anchoring KIT 3 15 7000 K 1 1 Shelf Holder KIT SS 3 15 0754 K BO 3 15 2018 3 Double Panel Connector for 3 8 Stainless Steel 3 15 2001 Black Oxide 3 15 2003 3 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 4: ...Outside Panel Width 3mm Cable SS 3 15 0723 BO 3 15 2006 Cable Coupler KIT SS 3 15 1639 K BO 3 15 2004 K Cable Tensioner with Cover Plate KIT SS 3 15 1636 K BO 3 15 2005 K 48 96 max Varia Panel Gauge 1 Shelf Holder KIT SS 3 15 0754 K BO 3 15 2018 Single Panel Connector for SS 3 15 1999 BO 3 15 2002 48 1219mm 96 2439mm max 14 floor to ceiling 50 3 8 1280mm 4 For more information please visit 3 form ...

Page 5: ...15 3 11A use a hammer to insert anchor 1 Install Ceiling Anchor for the First Cable Assembly If anchoring in concrete follow Steps 1a f if anchoring in drywall follow Steps 1g l if anchoring in wood follow Steps 1m n b c a Concrete Installation 5 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 ...

Page 6: ...Insert the metal channel through the drilled hole into the wall cavity Pull the metal channel firmly against the inner wall cavity by tugging the plastic pull ring Hollow Substrate Installation 1 Install Ceiling Anchor for the First Cable Assembly cont 6 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleS...

Page 7: ...Install Ceiling Anchor for the First Cable Assembly cont 3 15 175 4 3 1 5 0 7 9 1 SS 3 15 1639 BO 3 15 2004 n o m Drill Ø7 16 Ø11 1mm hole minimum 20mm deep Use an Allen wrench to install the M8 Threaded Insert 3 15 791 Wood Installation 7 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm I...

Page 8: ...floor anchor with the included M8 Threaded Rod 3 15 1754 Hang plumb bob to mark anchoring point on floor If anchoring in concrete follow Steps 1a f if anchoring in wood follow Steps 1g h 8 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 9: ...excess cable through the side exit on the tensioner Unscrew the cap 150 200 lbs 225 lbs max weight per cable Maximum Weight 225 lbs Maximum Tension 400 lbs Hollow Substrate Max Tension Weight 70lbs 9 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 10: ... 15 2002 x2 Set Screws a Do not tighten set screws b Do not tighten set screws 10 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 11: ... 2 Set Screws 2 SS 3 15 1999 BO 3 15 2002 Do not tighten set screws 11 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 12: ...d Measure cont Installation Remove Panel 12 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...

Page 13: ... ensure it is level Tighten set screws to the panel on top side brackets only a Position the top Side Brackets SS 3 15 1999 BO 3 15 2002 6 below the desired location of the top of the panel Tighten set screws to the cable top side brackets only 13 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200...

Page 14: ...xcess cable through the tensioner and tighten using Allen wrench through tensioner as shown in 6c Tighten set screws on lower side brackets once cables have been tensioned This will prevent gapping in tension on the cables 14 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Ma...

Page 15: ...d put a drop of super glue at end of cut cable to keep from fraying 15 For more information please visit 3 form com or call 800 726 0126 November 2019 MAN RTG 200 08 REV 003 2019 3form Inc All rights reserved SimpleSpec 200 08 tm Installation Manual Ready To Go ...