background image

OfficeConnect

®

Managed Gigabit Switch 

(3CDSG8)

Installation Guide

Summary of Contents for OfficeConnect 3CDSG8

Page 1: ...OfficeConnect Managed Gigabit Switch 3CDSG8 Installation Guide ...

Page 2: ...ut thereby achieving further reduction in power consumption You can be confident that your Switch will be taking the least amount of power but still providing the performance that you have come to expect from OfficeConnect The Switch is compact and attractively designed for desktop use It can be used with other units in the OfficeConnect family which include Cable DSL gateways wireless devices Fas...

Page 3: ...er adapter that is supplied with the Switch 7 SFP Port 1000BaseLX 3CSFP92 and 1000BaseSX 3CSFP91 transceivers are supported Use this interface to allow your Switch to connect across distances greater than 100m or where electrical isolation is required Appropriate multimode fiber cables will also be required not supplied SFP transceivers are hot insertable and hot swappable You can remove them from...

Page 4: ...irect sunlight and away from sources of heat Cabling is away from power lines fluorescent lighting fixtures and sources of elec trical noise such as radios transmitters and broadband amplifiers Water or moisture cannot enter the case of the unit Air flow around the unit and through the vents in the side of the case is not restricted 3Com recommends you provide a minimum of 25 mm 1 in clearance Usi...

Page 5: ...ect application that can be found on the CD that was supplied with the Switch Please follow the instructions below to determine and or configure the IP address of your switch Using the Console Interface 1 Connect the DB 9 to RJ 45 serial cable between your workstation to it s COM port and the Switch Take care not to connect it to a data port on the Switch 2 Using a terminal emulator program for ex...

Page 6: ...er will open and connect to the home page of the Switch 3 CONNECTING WORKSTATIONS Twisted Pair TP Cables Cables can be shielded screened or unshielded Cables must be Category 5 or above 3Com recommends Category 5E or 6 cable for Gigabit connections The maximum length you can use is 100 m 328 ft Twisted Pair TP cable is very easy to use To connect a TP cable simply slot the con nector into the rele...

Page 7: ... your region is 3C number Region 3C12VUS US and Canada 3C12VUK UK 3C12VME Europe and Middle East 3C12VAA Australasia 3C12VSA South Africa 3C12VKR Korea 3C12VRA Argentina Power LED lit but Status LED illuminated yellow This indicates that the switch is receiving power but for some reason the switch is not operational This is most likely due to a problem with the operational software in the unit not...

Page 8: ...8 Support and Safety Information ...

Page 9: ...ité importantes Avertissement Ces avertissements sont à respecter pour votre sécurité Lisez les attentivement Vous devez impérativement lire les consignes de sécurité suivantes avant de procéder à l installation ou à la désinstallation du matériel ou à toute activité d entretien Avertissement L installation et la désinstallation du matériel nécessite une vigilance exceptionnelle Avertissement Pour...

Page 10: ...buchsen können abgeschirmte oder nicht abgeschirmte Stecker angeschlossen werden Importanti informazioni di sicurezza Avvertenza Queste avvertenze precisano le direttive da seguire per la propria sicurezza personale Conformarsi con la massima attenzione a quanto precisato Leggere con attenzione le informazioni relative alla sicurezza prima di procedere all installazione o alla rimozione dell unità...

Page 11: ... de red A estos enchufes de datos se pueden conectar cables blindados o no blindados con tomas hembra blindadas o no blindadas Istotne Bezpieczeństwo Informacja Warning Ostrzeżenia zawierają wskazówki których należy przestrzegać w celu zagwarantowania bezpieczeństwa osobistego Do tych zaleceń należy stosować się dokładnie Przed przystąpieniem do instalacji usuwania urządzenia lub jakichkolwiek czy...

Page 12: ...ontent of at least 40 by weight and no heavy metal content For further details please refer to http www 3com com environment index html REGULATORY NOTICES FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the e...

Page 13: ...located at http knowledgebase 3com com It con tains thousands of technical solutions written by 3Com support engineers Purchase Extended Warranty and Professional Services To enhance response times or extend your warranty benefits you can purchase value added services such as 24x7 telephone technical support software upgrades onsite assistance or advanced hardware replacement Experienced engineers...

Page 14: ...Country Telephone Number Asia Pacific Rim Telephone Technical Support and Repair Australia 1800 075 316 Hong Kong 2907 0456 India 000 800 440 1193 Indonesia 001 803 852 9825 Japan 03 3507 5984 Malaysia 1800 812 612 New Zealand 0800 450 454 Philippines 1800 144 10220 or 029003078 P R of China 800 810 0504 Singapore 800 616 1463 South Korea 080 698 0880 Country Telephone Number Taiwan 00801 444 318 ...

Page 15: ...r AT T 800 988 2112 Equador AT T 800 988 2112 French Guyana AT T 800 988 2112 Grenada AT T 800 988 2112 Guadalupe AT T 800 988 2112 Guatemala AT T 800 998 2112 Guyana AT T 800 988 2112 Haiti AT T 800 988 2112 Country Telephone Number Honduras AT T 800 998 2112 Jamaica AT T 800 988 2112 Mexico 1800 849 2273 Mexico Local 52 55 52 01 0004 Monserrat AT T 800 998 2112 Nicaragua AT T 800 998 2112 Panama...

Page 16: ...ble media described in any documentation supplied with this product it is furnished under a license agreement included with the product as a separate document in the hard copy documentation or on the removable media in a directory file named LICENSE TXT or LICENSE TXT If you are unable to locate a copy please contact 3Com and a copy will be provided to you UNITED STATES GOVERNMENT LEGEND If you ar...

Reviews: