DUA1840-0AAA01
6-2
C
H
A
P
T
E
R
6:
P
R
O
B
L
E
M
S
O
L
V
I
N
G
Identifying Fault Conditions with the LEDs
The following table shows how you can identify possible fault
conditions that may occur during normal operation. It also describes
actions that may resolve the problem:
If you cannot solve the problem, contact your local supplier, or proceed
as described in
.
LED
Color
Indicates
Try the following actions
PWR
(Power)
Off
Power is not reaching the module
■
Check that the Power LED on the
MSH chassis is not lit red. If it is,
refer to your chassis user
documentation.
■
Ensure the MSH chassis is
powered-up correctly with all
power leads securely connected.
■
Ensure the module is fully
engaged into the chassis.
■
Contact your supplier for advice.
Faulty LED
■
Test LEDs to confirm.
Amber
Fault occurred on this module
during POST or normal operation
BACKPLANE
E, FE
Off
Fault
Faulty LED
■
Ensure module is fully engaged
into chassis and the backplane
connectors are fully mated.
■
Test LEDs to confirm.
1 - 12
(External port
status)
Off
Fault
■
Check all connections are secure.
■
Check all cables and connectors
for signs of damage.
Summary of Contents for MSH 1005
Page 1: ... MSH SWITCH 1005 USER GUIDE Part No DUA1840 0AAA01 Published June 1996 ...
Page 8: ......
Page 12: ...4 ABOUT THIS GUIDE ...
Page 61: ...DUA1840 0AAA01 Setting Up Users 2 27 ...
Page 91: ...DUA1840 0AAA01 3 30 CHAPTER 3 SWITCH CONFIGURATION ...
Page 107: ...DUA1840 0AAA01 4 16 CHAPTER 4 ADVANCED MANAGEMENT ...
Page 121: ...DUA1840 0AAA01 5 14 CHAPTER 5 STATUS MONITORING AND STATISTICS ...
Page 127: ...DUA1840 0AAA01 6 6 CHAPTER 6 PROBLEM SOLVING ...
Page 131: ...DUA1840 0AAA01 A 4 APPENDIX A SCREEN ACCESS RIGHTS ...
Page 151: ...6 CHAPTER INDEX ...
Page 155: ......