Setting Up the Switch Clock Source
119
Example
Enter:
1 8 2 5.1.2
The following message is displayed:
External clock source port 1 was successfully configured to
port 5.1.2.
Set External Clock
Source 2
Set a port to be the second external clock source port. If the port does
not exist, is disabled, is in loop timing mode, loopback or loop forward, it
cannot be used as an external clock source port.
Command Actions
Command Result
If the port has already been set to be the first or second clock source, it is
meaningless to set the port again. In this case, the command is ignored
and the following message is displayed:
Clock source 1 is already set to this port.
It is meaningless to set the two sources to the same port,
operation ignored.
Enter menu sequence:
(1) SYS: Platform Configuration
(8) SCS: Switch Clock Synchronization
Setup
(3) SP2: Set External Clock Source 2
Enter parameter at prompt
Parameter
Format or Range
Clock source
<slot.group.port> or
None
Direct access sequence:
1 8 3 [parameter]
System action:
The port is set to be the active clock source port.
System message display:
External clock source port 2 was
successfully configured to port
<slot.group.port>.
Summary of Contents for CoreBuilder 9000
Page 18: ......
Page 36: ...36 CHAPTER 1 OVERVIEW...
Page 44: ......
Page 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Page 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Page 306: ......
Page 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Page 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Page 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Page 374: ...374 CHAPTER 14 ATM SWITCHING...
Page 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Page 426: ......
Page 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Page 454: ...454 GLOSSARY...