Page 1: ...ver 1 06 04 20 VENUS AirGENIO Comfort INSTALLATION EN ...

Page 2: ...z 2 1 CHECKTHE SUPPLIED UNIT DONOTMISS Check immediately on delivery that the packaged product is not damaged In the event of damaged packaging consult the haulier In the event that any reclaim will not be applied in time future applications will not be processed Checkiftheproducttypeistheoneyouhaveordered Intheeventthatitisnottheorderedunit donotopenthepackagingandreport the fault to the supplier...

Page 3: ...thout turning it on allowing the temperature inside the unit to be levelled to the temperature of the surrounding area 2x 1x 4x 1x 1x Comfort 1 2 3 4 5 6 7 Duct connection outdoor air ODA Duct connection supply air SUP Duct connection diverted air ETA Duct connection exhaust air EHA Heat exchanger Fans Regulation unit connecting power and accessories Condensate drain Filters 8 9 1 2 2 6 5 3 4 4 7 ...

Page 4: ...since 1995 ver 1 06 04 20 4 DIMENSIONS HRV14 HRV15 a HRV30 HRV50 a HRV70 1114 960 26 31 15 57 20 20 1000 125 265 165 53 10 M8 159 555 270 135 20 515 65 1051 193 14 1 2 1505 10 M8 249 235 420 190 806 846 20 57 15 1351 26 31 1391 65 1441 248 14 1 2 52 20 360 180 20 ...

Page 5: ...A dB Duct diame ter mm Unit height mm Unit width mm Unit length mm HRV14EC 185 F7 G4 1 230 50 60 53 0 6 19 5 37 7 59 0 57 9 66 2 160 270 555 1000 HRV15EC 175 F7 G4 1 230 50 60 65 1 0 17 2 37 7 59 57 9 66 2 160 270 555 1000 HRV30EC 315 F7 G4 1 230 50 60 170 1 3 19 3 43 5 64 8 64 7 72 3 160 270 555 1000 HRV50EC 535 F7 G4 1 230 50 60 220 2 5 35 5 45 8 67 2 56 3 68 7 250 360 846 1391 HRV70EC 785 F7 G4...

Page 6: ...be installed in such a way that the direction of the air flow throughout the unit corresponds with the air flow in the distribution system The unit installation must allow for sufficient access for main tenance service purposes or its dismantling The access main ly concerns the revision lids allowing their opening 6 1 2 Required distances ATTENTION Non flammable materials must not obstruct the suc...

Page 7: ...low The siphon must be connected and sealed properly in the heat exchange unit ATTENTION Improper connection of the siphon may cause flooding and da mage to the heat exchange unit 5 DO NOT MISS Check the following prior to the first activation of the ventilation unit That unit is correctly attached to the framework That unit is closed properly all of the necks are connec tedtothepipelinesorprotect...

Page 8: ...om the unit neck should be 500 mm 6 3 2 Protective grid In the event that some of the necks of the unit will not be used forconnectingpipes itisnecessarytofixtheopeningwithagrid for protection from touching the rotating parts of ventilator heater bars etc YOU WILL NEED Side nut wrenches 4 flexible connection sleeves Cross head screwdriver Sealing tape sealant 6 3 CONNECTINGTHE AIR PIPING 6 3 1 Fle...

Page 9: ...f the unit is at least 80 cm Sensor channel EXT 1 color blue The sensor is already wired in the controller terminals 45 46 and must be installed in the fresh air duct from the outside to the unit see figure below The recommended distance between the sensor and the neck of the unit is at least 80 cm B F E A C D A3 8 5 7 6 2 4 3 1 C E D F A B 4 1 3 6 8 5 2 7 DATUM ISO 8015 ANO DRSNOST SCHVÁLIL ČÍSLO...

Page 10: ... must be turned off prior to any interferencewiththeinternalpartsoftheventilationunit The electro installation of the ventilation unit must be implemented according to the technical documentation issued by a qualified electro engineer The actual installa tion can be carried out by a professional educated in the electro field The manual instructions must be observed as well as the valid national re...

Page 11: ...U heater cooler Управляющий сигнал регулируемый SMU обогреватель кулер Sygnał sterujący do nastawienia SMU heater cooler Segnale di controllo impostabile SMU heater cooler Řídící signál nastavitelné SMU heater cooler Spatial sensor Внутренний датчик Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty Flap inlet fresh air Клапан свежего воздуха Klapa świeżego powietrza Aletta Aria fres...

Page 12: ... That all the electric components are properly connected That the condensate drain is connected to the sewage That the installation corresponds to the instructions in the manual That no tools or objects that may damage the unit have been left inside That the filters are clean ATTENTION Alterations and changes to the internal connections of the unit are forbidden and may result in the loss of warra...

Page 13: ... maintenance it is always necessary to remove unit from the working position there is a risk of injury Disassembly of the unit only in exceptional cases Clean the ventilation unit using a vacuum cleaner small brush cloth and soapy water especially recuperator Do not clean the unit with following Sharp objects aggressive chemicals sol vents abrasivecleaningproducts pressuredwater pressuredair or st...

Page 14: ...e spacers electronics groove pliers for precision mechanics disengaging the sheet like plate Philips screw No 0 Plastic components blanket insulation of the front panels breaking knife 9 CONCLUSION Once the it has been installed read carefully the safe operation manual of the unit That manual includes examples of possible problems and recommended solutions In case of any requests or inquiries cont...