2N

® 

Lift1 

Compact 

Comunicator for Lifts 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brief Manual  

Issue 2, Version 1.2

 

www.2n.cz

 

 

Summary of Contents for Lift1 Compact

Page 1: ...2N Lift1 Compact Comunicator for Lifts Brief Manual Issue 2 Version 1 2 www 2n cz ...

Page 2: ...sic version A PSTN or alternative PBX GSM gateway line is used for connection with the control centre Operation Press the ALARM button to activate connection The Wait pictogram goes on immediately and the Connection established symbol goes out when communication has been set up You can use automatic dialling of up to six pre programmed numbers Communication is accompanied by factory announcements ...

Page 3: ...for cable passage Round the hole edges to avoid cable damage Mounting The product mounting procedure may not be commenced until all electrical installations have been completed Remove the connectors screw the wires and replace the connectors for facilitation Refer to Mounting Completion for further steps Safety The Cancel Alarm1 Alarm2 and Phone terminals and the electronics board are connected to...

Page 4: ...ift travelling time For the Alarm 1 and Cancel input can be used switch button both with normally opened or normally closed contacts isolated The isolated voltage inputs can be activated by any voltage from 12 to 24 V The logic of inputs is to be set by parameters 920 for Alarm 1 916 for Cancel Connector NAME Description ALARM1 terminal DC voltage control 12 24 V DC any polarity activation by sign...

Page 5: ...ting If you can access the cabin wall from the outside use the mounting type that prevents dismantling and unauthorised tampering from the cabin Mounting procedure Where access from the outside is possible use the four pre drilled M4 holes in the corners Remove the corner covers fitted with four M4 screws from behind Screw the 30 mm long M4 headless grub screws included in the audio unit package i...

Page 6: ... the window forwards and remove it Now you have access to two holes in the window corners Put Lift1 on the pre drilled lift cabin wall holes and fit it with the included screws which are suitable for plywood chipboard laminated plastic etc walls For other materials use appropriate screws or M4 screws in the pre drilled M4 threaded holes Replace the window and insert the hex key wrench in the botto...

Page 7: ...d keep a timeout of 5 seconds or any other value in the range between 1 and 9 for each character to avoid Lift1 hang up and password parameter re entering Programming Procedure Having entered the programming mode you can change any programmable value s in any order Proceed as follows enter the parameter number and value Use an asterisk as a separator or Enter In general the function has the follow...

Page 8: ...nual 012 016 ALARM button memories 2 6 up to 16 digits empty 071 Check call memory 1 up to 16 digits empty 072 076 Check call memories 2 6 up to 16 digits empty 018 Count of automatic dialling cycles for ALARM 0 9 3 cycles 078 Count of automatic dialling cycles for check call 0 9 3 cycles 111 Automatic dialling type for ALARM button memory 1 1 6 1 1 loud with confirmation 2 silent with confirmatio...

Page 9: ...sh 8 Portugese 9 Dutch 10 to 99 silence 877 Outgoing call message language selection 0 99 1 912 Maximum call time 15 990 s 120 s Use the call extending command to extend the call DTMF 4 or 913 Login time limit for automatic dialling 10 990 s 60 s Set the maximum period of time for the control centre staff to answer the call and send confirmation otherwise Lift1 hangs up and dials the next number C...

Page 10: ...urs and then as set in parameter 983 3 enabled call as set in parameter 983 4 enabled call on the nearest day set in parameter 986 5 enabled first call in 3 minutes and then as set in parameter 986 6 as set by the server 982 Check call interval 00 00 00 23 59 59 beginning and end beg 00 00 0 0 end 23 59 5 9 Set announcements for the lower traffic lower tariff time generated at random in the set ti...

Page 11: ...0 dB 2 5 2 0 dB 15 to 60 mA Overvoltage protection between A B 1000 V 8 20 μs Other Parameters Compact model dimensions 100 x 185 x 23 mm Working temperature range 20 to 70 C Note Lift1 is certified for connection to a wired PSTN line according to the ES 023 021 standard requirements The product does not contain components harmful to the environment When the product s service life is exhausted dis...

Page 12: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Česká Republika Tel 420 261 301 111 fax 420 261 301 999 E mail sales 2n cz Web www 2n cz 2274v1 2 ...