Lift Induction Loop Amplifier 

Instructions for Use 

Product Description 

The device is a part of sound system installations for hearing impaired persons that are equipped with 
a special hearing aid capable of receiving reproduced sound via a magnetic field receiver. This version 
of the product is dedicated particularly for installations in lift cabin. Part of delivery is the induction loop 
for the lift cabin roof and cable for connection to lift communicators produced by 2N Telekomunikace. 
The system is defined by the IEC 60118-4 standard. The device is delivered with one input (ordering 
number 919621E) or dual input (919622E), to allow connection of another sound source. 

Installation 

Open the box for amplifier using the space for flat bladed screwdriver on the side of the box. 
Depending on cable connection cut out holes in the bottom of the box or in the cover. For standard 
installation suffice to cut out marked area in the cover. Fix the bottom part of the box to the roof or the 
wall of the lift cabin by self adhesive foil or screws. After connecting power and signal cable to the 
terminals on the amplifier board push the board to the proper position in the bottom part of the box and 
put the cover on the box. Finally connect the induction loop, delivered with the device, to the 
connectors LOOP1 and LOOP2, eventually your own loop to terminal EXTERNAL ANTENNA. 

The loop is made by RJ cable and has six loops connected in serial should be fixed behind the cabin 
roof. The area of the loop should be as big as possible

, the loop shouldn’t be covered by metallic parts. 

It can be placed in lights, behind ledges or similarly. If you use different loop than the delivered one, 
connect it into the plug EXTERNAL ANTENNA on the amplifier board and use the cut for cables for the 
connection. The loop should be done by few windings in serial connection (multicore cable can be 
used) with proper dimension. 

Connect the delivered signal cable to terminals marked IN+ and IN-, the connector on this cable suits 
into the lift communicators 2N

® 

Lift1 a 2N

® 

Lift8. For connection to another device connect the input to 

the speaker of the signal source in parallel. In dual input version the input signals are mixed. 

For power connection use 12V DC. When the 12V power is not present, you can use the power 
adaptor supplied by 2N Telekomunikace (ordering number 9159052). When using this power supply, 
cut off the supply jack, A negative wire is marked with a white strip along the cable. Connect the power 
to terminal 12V and GND on the amplifier board. The device is equipped with overvoltage 
and power supply polarity reversal protection, but always make sure that the power supply voltage and 
polarity values are met. The LED on is illuminated when the power is connected. 

Amplifier Setting and Testing 

The amplifier is pre-set for connection to 2N

® 

Lift1 a 2N

® 

Lift8, there is no need for setting. For 

connection to another device you can set the gain of the amplifier by potentiometer VOLUME. When 
you perform the volume setting, the test of functionality, volume and clarity of voice must be done by 
appropriate receiver of the induction signal or by tester. The amplifier is switched on by input signal, 
this function can be disabled 

by jumper “Permanent on”. 

Summary of Contents for Lift Induction Loop Amplifier

Page 1: ...ossible the loop shouldn t be covered by metallic parts It can be placed in lights behind ledges or similarly If you use different loop than the delivered one connect it into the plug EXTERNAL ANTENNA on the amplifier board and use the cut for cables for the connection The loop should be done by few windings in serial connection multicore cable can be used with proper dimension Connect the deliver...

Page 2: ...g Output short circuit resistance unlimited time Frequency characteristics 100 Hz 5 kHz 3 dB Temperature range 20 50 C Dimensions 80x80x30 mm Recomended load for optimal efficiency 2 4 Ω Declaration of Conformity Hereby 2N TELEKOMUNIKACE a s declares the equipment type 2N LIFT Induction Loop Amplifier is in compliance with directives 2014 53 EU and 2011 65 EU The full text of the EU declaration of...

Page 3: ... do světla do lišt a podobně Pokud použijete jinou smyčku než je dodána připojte ji do konektoru EXTERNAL ANTENNA na desce zesilovače a vodiče vyveďte výřezem nebo otvorem v krabičce Smyčka by měla mít několik závitů lze realizovat vícežilovým kabelem vhodného průřezu Do šroubovacích svorek vstupu zesilovače s označením IN a IN připojte přiložený signálový kabel který je na druhé straně opatřen ko...

Page 4: ...podle nastavení Odolnost výstupu proti zkratu neomezená doba Kmitočtová charakteristika 100 Hz 5 kHz 3 dB Teplotní rozsah 20 50 C Rozměry 80x80x30 mm Doporučená zátěž pro optimální účinnost 2 4 Ω Prohlášení o shodě 2N TELEKOMUNIKACE a s tímto prohlašuje že zařízení typ 2N LIFT zesilovač pro indukční smyčku je ve shodě se směrnicemi 2014 53 EU a 2011 65 EU Úplné znění EU prohlášení o shodě je k dis...

Reviews: