5.6.1 Babycall
The Babycall folder helps you set automatic calls. If the Babycall function is enabled, a
defined period of time is counted down after the phone off-hook (the default value is
5000 ms). Unless you start dialing by the end of this timeout,
signals
2N EasyGate IP
®
the dialing end and starts setting up a call to the predefined phone number – from this
moment on,
behaves as if dialing was terminated in a standard
2N EasyGate IP
®
outgoing call. Any dialing during the Babycall timeout countdown cancels this
function and a standard outgoing call is made.
Enable – enable/disable the Babycall function, automatic call without dialing.
Time – set the time interval between the line off-hook and automatic call
beginning.