background image

Copyright © 2014 Linear LLC

   

1

2GIG-PIR1-345

PASSIVE INFRARED MOTION DETECTOR

INSTALLATION INSTRUCTIONS

The

 

Passive

 

Infrared

 

Motion

 

Detector

 

(2GIG

PIR1

345)

 

is

 

a

 

wall

mounted

 

unit

 

with

 

wide

angle

 

motion

 

protection.

 

It

 

communicates

 

with

 

the

 

2GIG

 

Control

 

Panel

 

using

 

the

 

345

 

MHz

 

frequency.

 

When

 

set

 

to

 

High

 

(HI)

 

Sensitivity

 

Mode,

 

the

 

PIR

 

has

 

a

 

maximum

 

range

 

of

 

30

 

ft

 

deep

 

x

 

50

 

ft

 

wide

 

(9.1

 

m

 

x

 

15.2

 

m).

 

The

 

PIR’s

 

pet

immune

 

feature

 

can

 

be

 

set

 

to

 

tolerate

 

animals

 

up

 

55

 

lbs.

Figure 1  

Passive Infrared Motion Detector

Box Contents

Verify

 

that

 

the

 

package

 

includes

 

the

 

following

 

(see

 

Figure

 

3

  

PIR

 

and

 

Mounting

 

Bracket

 

Detail

 

on

 

page

 

2):

1—Passive

 

Infrared

 

Motion

 

Detector

 

(Part

 

A)

1—Plastic

 

Mounting

 

Bracket

 

(Part

 

B)

1—Plastic

 

Wall

 

Mount

 

(Part

 

C)

1—Plastic

 

Corner

 

Mount

 

(Part

 

D)

2—Plastic

 

Wall

 

Anchors

 

With

 

Screws

 

(not

 

pictured)

1—Short

 

Phillips

 

Head

 

Screw

 

with

 

Fender

 

(not

 

pictured)

1—Short

 

Phillips

 

Head

 

Screw

 

(not

 

pictured)

1—Lithium

 

Coin

 

Battery

 

(not

 

pictured)

Inserting and Replacing the Battery

To

 

insert

 

or

 

replace

 

the

 

battery:

1

Unwrap

 

the

 

PIR

 

and

 

remove

 

the

 

screw

 

from

 

the

 

case

 

bottom.

2

Remove

 

the

 

backplate

 

using

 

a

 

bottom

to

top

 

lifting

 

motion.

3

Insert

 

the

 

battery.

 

Always

 

match

 

the

 

plus

 

(+)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

flat

 

side

 

of

 

the

 

compartment

 

and

 

the

 

minus

 

(

)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

spring

 

side.

4

Replace

 

the

 

PIR

 

cover.

WARNING: 

Failure

 

to

 

follow

 

these

 

warnings

 

and

 

instructions

 

can

 

lead

 

to

 

heat

 

generation,

 

rupture,

 

leakage,

 

explosion,

 

fire,

 

or

 

other

 

injury,

 

or

 

damage.

 

Do

 

not

 

insert

 

the

 

battery

 

into

 

the

 

compartment

 

in

 

the

 

wrong

 

direction.

 

Always

 

replace

 

the

 

battery

 

with

 

the

 

same

 

or

 

equivalent

 

type

 

(see

 

Specifications

 

on

 

page

 

4).

 

Never

 

recharge

 

or

 

disassemble

 

the

 

battery.

 

Never

 

place

 

the

 

battery

 

in

 

fire

 

or

 

water.

 

Always

 

keep

 

batteries

 

away

 

from

 

small

 

children.

 

If

 

batteries

 

are

 

swallowed,

 

promptly

 

see

 

a

 

doctor.

 

Always

 

dispose

 

and/or

 

recycle

 

used

 

batteries

 

in

 

accordance

 

with

 

the

 

hazardous

 

waste

 

recovery

 

and

 

recycling

 

regulations

 

for

 

your

 

location.

 

Your

 

city,

 

state,

 

or

 

country

 

may

 

also

 

require

 

you

 

to

 

comply

 

with

 

additional

 

handling,

 

recycling,

 

and

 

disposal

 

requirements.

 

Configuring the PIR Features

Ensure

 

that

 

you

 

have

 

inserted

 

the

 

PIR

 

battery

 

as

 

described

 

in

 

Inserting

 

and

 

Replacing

 

the

 

Battery

.

 

Then

 

configure

 

the

 

features

 

as

 

follows:

Figure 2  

PIR Pet Immune and Sensitivity Features

Step 1: Setting the Pet Immune Feature

To

 

set

 

the

 

pet

 

immune

 

feature

 

to

 

an

 

appropriate

 

weight:

NOTE: 

Do

 

not

 

aim

 

the

 

PIR

 

at

 

stairs,

 

furniture,

 

or

 

other

 

surfaces

 

that

 

a

 

pet

 

may

 

climb

 

on.

 

The

 

PIR

 

provides

 

immunity

 

when

 

the

 

room

 

temperature

 

is

 

above

 

50°

 

F

 

(10°

 

C)

 

and

 

below

 

90°

 

F

 

(32°

 

C).

 

When

 

mounting

 

the

 

PIR

 

with

 

the

 

plastic

 

mounting

 

bracket,

 

for

 

best

 

protection

 

ensure

 

the

 

PIR

 

is

 

mounted

 

to

 

the

 

wall

 

or

 

corner

 

with

 

NO

 

tilt

 

(see

 

Lens

 

Pattern

 

and

 

Tilt

 

Angles

 

on

 

page

 

3).

1

With

 

the

 

backplate

 

off,

 

locate

 

the

 

left

 

jumper

 

block

 

immediately

 

above

 

the

 

battery

 

compartment.

 

This

 

is

 

the

 

block

 

labeled

 

PET

 

(see

 

Figure

 

2

  

PIR

 

Pet

 

Immune

 

and

 

Sensitivity

 

Features

).

2

Gently

 

pull

 

out

 

the

 

jumper

 

and

 

slip

 

it

 

over

 

the

 

desired

 

pins

 

to

 

set

 

one

 

of

 

the

 

pet

immune

 

tolerance

 

settings:

33

 

LBS

.

 

Tolerates

 

pets

 

up

 

to

 

33

 

lbs

 

(15

 

kg).

OR

55

 

LBS

 

(Default).

 

Tolerates

 

pets

 

up

 

to

 

55

 

lbs

 

(25

 

kg).

 

3

Continue

 

with

 

the

 

next

 

step

 

below.

 

Step 2: Setting the Sensitivity Feature

1

Locate

 

the

 

right

 

jumper

 

block

 

immediately

 

above

 

the

 

battery

 

compartment

 

on

 

the

 

right.

 

This

 

is

 

the

 

block

 

labeled

 

SENS

 

(see

 

Figure

 

2

  

PIR

 

Pet

 

Immune

 

and

 

Sensitivity

 

Features

).

2

Gently

 

pull

 

out

 

the

 

jumper

 

and

 

slip

 

it

 

over

 

the

 

desired

 

pins

 

to

 

set

 

the

 

desired

 

sensitivity

 

mode:

LOW

 

(Default).

 

Low

 

sensitivity.

 

This

 

is

 

the

 

recommended

 

setting

 

for

 

pets.

OR

HIGH

.

 

High

 

sensitivity.

 

3

Continue

 

with

 

Step

 

3:

 

Powering

 

ON

 

the

 

PIR

 

on

 

page

 

2.

A

PET:

 

This

 

is

 

the

 

pet

immune

 

tolerance

 

setting

 

(33

 

LBS

 

or

 

55

 

LBS).

B

TAMPER:

 

This

 

is

 

the

 

tamper

 

switch.

C

SENS:

 

This

 

is

 

the

 

sensitivity

 

setting

 

(High

 

or

 

Low).

Summary of Contents for pir1-345

Page 1: ...ly see a doctor Always dispose and or recycle used batteries in accordance with the hazardous waste recovery and recycling regulations for your location Your city state or country may also require you to comply with additional handling recycling and disposal requirements Configuring the PIR Features Ensure that you have inserted the PIR battery as described in Inserting and Replacing the Battery T...

Page 2: ... On the intended wall use the two 2 Plastic Wall Anchors to hang the Plastic Wall Mount at a height of 7 5 ft 2 3 m 2 Locate the barrel end of the Plastic Mounting Bracket Locate the barrel end of the Plastic Mounting Bracket and carefully set it onto the ribbed pin of the Plastic Wall Mount at the desired angle see Lens Pattern and Tilt Angles on page 3 3 From the topside of the Plastic Wall Moun...

Page 3: ...e of 95 to 120 F the detection performance of the PIR decreases 6 Ensure that the area you wish the PIR to cover is free of obstructions for example curtains screens plants and so on that may block the pattern of coverage 7 Anything that can sway or move due to air current can cause a change in infrared energy within the fields of view Drafts from doors or windows can cause this to happen Plants b...

Page 4: ...CC radiation exposure limits for an uncontrolled environment Avoid operating this product at a distance less than 20 cm from the user CAUTION Any changed or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Industry Canada IC Compliance This device complies with Industry Canada license exempt RSS standard s Operat...

Reviews: