background image

©2013 2GIG by Linear Corporation. All Rights Reserved.    

1

Super Switch (Takeover Module)

INSTALL INSTRUCTIONS

The

 

2GIG

TAKE

345

 

Super

 

Switch

 

is

 

2GIG’s

 

wireless

 

takeover

 

module.

 

This

 

unit

 

was

 

designed

 

to

 

convert

 

8

 

hardwired

 

zones

 

into

 

eight

 

wireless

 

zones,

 

make

 

installation

 

simple,

 

and

 

work

 

with

 

existing

 

12

volt

 

control

 

panels.

 

The

 

module

 

is

 

to

 

be

 

mounted

 

next

 

to

 

the

 

existing

 

Control

 

Panel

 

where

 

the

 

hardwired

 

zones

 

are

 

connected.

 

All

 

of

 

the

 

zones

 

on

 

the

 

Super

 

Switch

 

act

 

as

 

supervised

 

wireless

 

zones.

IMPORTANT: 

If

 

the

 

control

 

panel

 

has

 

been

 

removed

 

then

 

a

 

12

volt

 

power

 

supply

 

with

 

battery

 

backup

 

is

 

required

 

(not

 

supplied).

Box Contents

Takeover

 

Module

Mounting

 

Plate

2

 

Phillips

 

head

 

screws

2

 

Plastic

 

drywall

 

anchors

PROGRAMMING

The

 

following

 

steps

 

are

 

guidelines

 

for

 

programming

 

(learning)

 

the

 

Super

 

Switch

 

into

 

the

 

2GIG

 

Control

 

Panel.

 

Scroll

 

between

 

op ons

 

using

 

the

 ← 

and

 → 

arrows.

 

Move

 

to

 

the

 

previous

 

or

 

next

 

prompt

 

by

 

pressing

 

the

 ↑ 

and

 ↓ 

arrows.

 

1

Select

 

RF

 

sensor

 

#(01

 

to

 

48).

 

Assign

 

the

 

Takeover

 

Module

 

to

 

a

 

new

 

zone.

(Terminals

 

1

8)

2

Select

 

RF

 

sensor

 

type.

 

(01)

 

Exit/Entry

(02)

 

Exit/Entry

(03)

 

Perimeter

(04)

 

Interior

 

Follower

3

Select

 

RF

 

equipment

 

type.

4

Select

 

RF

 

sensor

 

equipment

 

code.

 

Enter

 

0873

 

for

 

the

 

2GIG

TAKE

345

 

module.

5

Enter

 

RF

 

sensor

 

serial

 

number

 

(7

 

digits).

Manual

 

Entry:

 

Type

 

in

 

the

 

last

 

7

digit

 

serial

 

number

 

that

 

ends

 

in

 

“1”

 

(XXX

XXXX1)

 

that

 

is

 

found

 

on

 

the

 

back

 

of

 

the

 

Super

 

Switch

 

(this

 

is

 

the

 

serial

 

number

 

for

 

Zone

 

1).

For

 

each

 

additional

 

zone,

 

add

 

a

 

digit

 

to

 

the

 

end

 

of

 

the

 

serial

 

number.

 

For

 

example,

 

Zone

 

(terminal)

 

2

 

will

 

be

 

(XXX

XXX2)

Auto

 

Entry:

 

With

 

the

 

panel

 

in

 

Learn

in

 

mode

 

(press

 

Shift

 

then

 

Learn

)

 

trip

 

the

 

zone

 

that

 

you

 

want

 

to

 

learn

 

in.

 

The

 

correct

 

TX

 

ID

 

should

 

appear.

 

Accept

 

the

 

correct

 

TX

 

ID

 

by

 

pressing

 

ok

.

Remember

 

to

 

press

 

the

 ↓ 

arrow

 

to

 

continue

 

through

 

the

 

system

 

configuration

 

prompts.

6

Select

 

RF

 

sensor

 

equipment

 

age.

(0)

 

new

 

(product

 

is

 

new)

7

Select

 

RF

 

sensor

 

loop

 

number

 

(1).

(1)

 

1

8

Select

 

RF

 

sensor

 

1

 

dialer

 

delay.

(0)

 

disabled

 

(1)

 

enabled

 

9

Construct

 

RF

 

sensor

 

descriptor.

 

Press

 

Insert

 

then

 

press

 

any

 

number

 

between

 

002

 

and

 

255

 

to

 

add

 

a

 

word.

 

For

 

example,

 

if

 

you

 

wanted

 

to

 

name

 

this

 

Takeover

 

Module

 

as

 

“Wireless

 

Sensor

 

Tool,”

 

press

 

Insert

 

then

 

press

 

252

 

for

 

WIRELESS

.

 

Press

 

Insert

 

then

 

press

 

191

 

for

 

SENSOR

.

 

Press

 

Insert

 

then

 

press

 

233

 

for

 

TOOL

.

10

Select

 

RF

 

sensor

 

reports

 

(0

 

to

 

1).

(0)

 

disabled

 

(sensor

 

does

 

NOT

 

report

 

to

 

the

 

central

 

station)

(1)

 

enabled

 

(sensor

 

reports

 

to

 

the

 

central

 

station)

11

Select

 

RF

 

sensor

 

supervised

 

(0

 

to

 

1).

(0)

 

disabled

 

(sensor

 

does

 

NOT

 

report

 

loss

 

of

 

supervision

 

or

 

low

 

battery)

(1)

 

enabled

 

(sensor

 

reports

 

loss

 

of

 

supervision

 

or

 

low

 

battery)

12

Select

 

RF

 

sensor

 

chime

 

(0

 

to

 

13).

(0)

 

disabled

 

(panel

 

will

 

not

 

chime

 

when

 

sensor

 

is

 

activated)

(1

13)

 

enabled

 

(selects

 

a

 

voice

 

and/or

 

chime

 

to

 

sound

 

when

 

sensor

 

is

 

activated)

13

To

 

program

 

another

 

sensor,

 

click

 

next

.

 

14

To

 

exit

 

programming,

 

click

 

skip

 

then

 

end

 

and

 

exit

.

 

Upon

 

exit,

 

the

 

panel

 

takes

 

a

 

few

 

seconds

 

to

 

reset.

FOR

 

UL/ETL

 

Listed

 

Installations

 

use

 

the

 

following

 

equipment:

 

Altronix

 

(TM)

 

power

 

supply/charger

 

model

 

#AL100UL

 

with

 

an

 

Altronix

 

(TM)

 

plug

in

 

transformer,

 

model

 

#TP1620

 

and

 

a

 

Power

 

Sonic

 

Model

 

PS

1212

 

12

 

Volt

 

1.4

 

Amp

 

Hour

 

rechargeable

 

sealed

 

lead

 

acid

 

battery

 

or

 

equivalent.

 

See

 

"Using

 

the

 

Altronix

 

Power

 

Supply"

 

on

 

page

 

3.

Monitoring the Battery

The

 

Super

 

Switch

 

will

 

operate

 

on

 

the

 

connected

 

battery

 

if

 

there

 

is

 

an

 

AC

 

failure,

 

unless

 

the

 

battery

 

is

 

not

 

capable

 

of

 

supplying

 

enough

 

power.

 

The

 

Super

 

Switch

 

monitors

 

the

 

battery

 

to

 

ensure

 

it

 

is

 

operational.

 

When

 

the

 

Super

 

Switch

 

detects

 

a

 

battery

 

voltage

 

below

 

normal

 

level

 

for

 

a

 

period

 

of

 

time,

 

the

 

Super

 

Switch

 

reports

 

a

 

low

 

battery

 

for

 

each

 

zone

 

(if

 

programmed

 

in

 

step

 

11

 

under

 

Programming).

Testing the Battery Voltage

If

 

you

 

get

 

a

 

“Low

 

Battery”

 

Indicator,

 

do

 

the

 

following:

1

Test

 

the

 

battery’s

 

voltage

 

with

 

a

 

volt

 

reader

 

to

 

ensure

 

that

 

12

 

volts

 

are

 

passing

 

through

 

the

 

switch.

2

If

 

the

 

battery

 

is

 

fine,

 

remove

 

power

 

from

 

the

 

Super

 

Switch

 

(disconnect

 

battery

 

and

 

AUX

 

power

 

terminal

 

2).

3

Rewire

 

the

 

Super

 

Switch

 

by

 

connecting

 

the

 

battery

 

first.

4

After

 

the

 

Super

 

Switch

 

is

 

powered

 

by

 

the

 

battery,

 

connect

 

AUX

 

power

 

to

 

terminal

 

2

 

on

 

the

 

Super

 

Switch.

5

Remove

 

power

 

from

 

the

 

Control

 

Panel

 

and

 

then

 

power

 

up

 

the

 

Control

 

Panel.

 

If

 

everything

 

is

 

connected

 

correctly,

 

the

 

“Low

 

Battery”

 

indicator

 

should

 

disappear.

IMPORTANT: 

If

 

there

 

is

 

no

 

existing

 

system,

 

then

 

use

 

your

 

own

 

power

 

supply

 

and

 

group

 

all

 

of

 

the

 

ground

 

wires

 

together

 

and

 

connect

 

them

 

to

 

the

 

ground

 

port

 

on

 

the

 

Super

 

Switch.

INSTALLING AND MOUNTING

Screw

 

the

 

mounting

 

bracket

 

to

 

a

 

wall

 

and

 

attach

 

the

 

Super

 

Switch.

 

To

 

release

 

the

 

bracket,

 

pull

 

up

 

on

 

the

 

tab

 

and

 

slide

 

the

 

bracket

 

down.

 

Mount

 

the

 

bracket

 

with

 

2

 

screws.

 

Mount

 

the

 

Super

 

Switch

 

in

 

RF

 

range

 

of

 

the

 

Control

 

Panel

.

To Wire Super Switch with an Existing Power Source

*See

 

Figure

 

1

 

on

 

next

 

page

1

Remove

 

AC

 

power

 

from

 

existing

 

wired

 

panel.

2

Remove

 

leads

 

from

 

battery

 

on

 

existing

 

wired

 

panel.

3

With

 

power

 

removed,

 

wire

 

the

 

zones

 

to

 

the

 

Super

 

Switch.

 

Terminals

 

3

10

 

are

 

marked

 

as

 

Zones

 

1

8

 

on

 

the

 

Super

 

Switch

 

and

 

are

 

where

 

the

 

zones

 

are

 

connected.

 

For

 

example,

 

to

 

wire

 

zone

 

1

 

on

 

the

 

Super

 

Switch

 

take

 

the

 

positive

 

or

 

HI

 

side

 

of

 

the

 

zone

 

off

 

the

 

existing

 

panel

 

and

 

place

 

it

 

in

 

terminal

 

3/Zone

 

1

 

on

 

the

 

Super

 

Switch.

 

Leave

 

the

 

negative

 

side

 

or

 

the

 

LO

 

(GND)

 

side

 

of

 

the

 

zone

 

wired

 

to

 

the

 

existing

 

Control

 

Panel.

4

Repeat

 

this

 

procedure

 

for

 

all

 

zones

 

to

 

be

 

connected

 

to

 

the

 

Super

 

Switch.

TIP: 

An

 

option

 

is

 

to

 

remove

 

all

 

LO

 

wires

 

from

 

existing

 

panel,

 

group

 

them

 

together,

 

and

 

connect

 

them

 

to

 

the

 

ground

 

port.

WARNING: 

THIS

 

IS

 

NOT

 

FOR

 

USE

 

IN

 

A

 

UL/ETL

 

LISTED

 

INSTALLATION.

To Wire Super Switch without an Existing Power Source

See

 

"Using

 

Existing

 

System

 

Wiring"

 

on

 

page

 

3.

*See

 

Figure

 

2

 

on

 

next

 

page

IMPORTANT: 

Before

 

connecting

 

power

 

to

 

the

 

Super

 

Switch,

 

wire

 

the

 

zones

 

to

 

the

 

Super

 

Switch.

 

Terminals

 

3

10

 

are

 

marked

 

as

 

Zones

 

1

8

 

on

 

the

 

Super

 

Switch.

 

For

 

example,

 

to

 

wire

 

zone

 

1

 

on

 

the

 

Super

 

Switch

 

take

 

the

 

positive

 

or

 

HI

 

side

 

of

 

the

 

zone

 

place

 

it

 

in

 

terminal

 

3/Zone

 

1

 

on

 

the

 

Super

 

Switch.

1

Repeat

 

above

 

for

 

all

 

zones

 

to

 

be

 

connected

 

to

 

the

 

Super

 

Switch.

2

Group

 

all

 

LO/(GND)

 

wires

 

together

 

and

 

connect

 

them

 

to

 

terminal

 

1/G

 

(GND

 

Port

 

of

 

the

 

Super

 

Switch.

WARNING: 

DO

 

NOT

 

PLUG

 

THE

 

POWER

 

SUPPLY/CHARGER

 

PLUG

IN

 

TRANSFORMER

 

INTO

 

AN

 

OUTLET

 

CONTROLLED

 

BY

 

A

 

SWITCH.

Powering the Super Switch and Other Devices

1

The

 

Super

 

Switch

 

has

 

two

 

wires

 

attached

 

RED

 

(+)

 

and

 

BLACK

 

(

).

 

Connect

 

the

 

Red

 

wire

 

to

 

the

 

red

 

terminal

 

and

 

the

 

black

 

wire

 

to

 

the

 

black

 

terminal

 

on

 

the

 

existing

 

Control

 

Panel’s

 

battery.

2

Connect

 

the

 

wires

 

from

 

the

 

existing

 

Control

 

Panel

 

for

 

the

 

battery

 

into

 

the

 

spades

 

lugs

 

on

 

top

 

of

 

the

 

wires

 

from

 

the

 

Super

 

Switch

 

that

 

is

 

now

 

connected

 

to

 

the

 

battery.

3

IF

 

USING

 

AN

 

EXISTING

 

POWER

 

SOURCE:

 

Wire

 

the

 

existing

 

panels

 

AUX

 

power

 

out

 

to

 

terminal

 

2/12V

 

port

 

on

 

the

 

Super

 

Switch.

 

If

 

you

 

are

 

using

 

the

 

Super

 

Switch

 

with

 

PIRs,

 

Glass

 

Break

 

Detectors,

 

or

 

other

 

devices

 

that

 

need

 

power,

 

then

 

they

 

must

 

receive

 

power

 

from

 

the

 

AUX

 

power

 

on

 

the

 

existing

 

Control

 

Panel.

 

Reconnect

 

AC

 

power

 

to

 

existing

 

panel.

NOTE: 

Remove

 

all

 

other

 

devices

 

wired

 

to

 

AUX

 

power

 

on

 

the

 

existing

 

Control

 

Panel

 

(such

 

as

 

keypads

 

or

 

any

 

other

 

unused

 

devices

 

requiring

 

power).

WARNING: 

THIS

 

IS

 

NOT

 

FOR

 

USE

 

IN

 

A

 

UL/ETL

 

LISTED

 

INSTALLATION.

Reviews: