background image

Doorbell

2GIG-DBELL1-345

Operating Instructions

The 2GIG-DBELL1-345 is a dual purpose doorbell that will work with both 

the standard 24V wiring in the house and also wirelessly with the 2GIG 

Control Panel. It features a button that will remain illuminated when hooked 

to the 24V house door bell wiring and is fully water resistant.

Installation & Mounting Guidelines

Programming

Testing

Figure 1

Figure 3

To complete the installation:

To mount the base, do the following:

Mount the DBELL1 on the door frame using the orientation shown in Figure 2. Use the 

supplied phillips head screws to attach it to the surface.

Pull the existing house 24V AC wiring through the hole in the rear of the base.

Place the supplied O-ring around the perimeter of the base as shown in Figure 2.

1

2

3

Notes:

If possible, locate sensors within 100 ft (30 m) of the panel, While a transmitter may have a 

range of 350ft. (106 m) or more out in the open, the environment at the installation site can 

have a significant effect on transmitter range. Sometimes a change in sensor orientation 

can help overcome adverse wireless conditions.

Although the DBELL1 has been designed to withstand weather, avoid mounting sensors in 

areas where they will be exposed to extreme moisture or where the sensor operating 

temperature range of 32 to 120°F (0 to 49°C) will be exceeded.

Set the panel to sensor learning mode.

Press and release doorbell button on the sensor until the panel responds (see Figure 1).

Exit program mode.

Verify that the household wiring is also working by sounding the doorbell.

1

2

3

4

Put the control panel into sensor test mode.

Press and release the doorbell button and listen for siren or keypad beeps to determine 

appropriate response (refer to the control panel Installation instructions).

Exit sensor test mode.

Verify that the household 24V AC connection is working by pressing the doorbell button to ring 

the doorbell.

1

2

3

4

Attach the existing 24V AC household doorbell wiring to base of the module using 6-32 x 

1/8” machine screws. If this step is skipped, the door bell will work only with the 2GIG 

control module and the LED will not be illuminated. Refer to Figure 3.

Pull the battery tab out and discard.

Snap the top part of the assembly to the base.

Assembly is now complete.

1

2

3

4

The following steps describe general guidelines for programming (learning) the 

sensor into the alarm control panel memory. For more details, refer to the 2GIG 

Installation & Programming Instructions.

Before mounting the sensor, verify that the sensor mounting location provides good 

RF communication to the panel. To verify, do the following:

Note: It is recommended that a system test be performed per the Operation & User's Guide at least once a year.

2GIG

     ©2011

SLIDE BATTERY IN HERE

PLUS SIDE UP

Battery Pull T

ab

Access hole 24V

door bell wire

Screw

mounting

features

Figure 2

Slot for

O-ring

Doorbell button