background image

 

Two Dimensional Instruments, LLC 

 P O Box 159 

 Crestwood, KY 40014 

(877) 241-0042   

  (502) 243-0039 fax  

  (502) 243-0042 international 

 
Table of Contents 

 
 
 
 

Component and Packing List 

 

pg   4

 

Quick Start

 

pg   5

 

Sensor Setup 

pg  6 

Setting the Alarms 

pg  7 

Installation Tips 

 

pg  8

 

TV2 Status Screen 

pg  9 

LED & Reset controls

 

pg 10

 

Navigating with Easy Touch 

pg 10 

Main Menu 

 

pg 12

 

Operational Modes

 

pg 14

 

Main Mode

 

pg 15

 

Trace Mode

 

pg 17

 

Sleep Mode 

pg 18 

Calibration 

pg 19 

TView Software 

 

pg 21

 

Frequently Asked Questions 

pg 31 

Appendix  

Pg 36 

Disclaimers 

Pg 36 

Warranty 

pg 37 

FCC & CE Mark Certifications

 

pg 38

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TV2

Page 1: ...Two Dimensional Instruments LLC P O Box 159 Crestwood KY 40014 877 241 0042 502 243 0039 fax 502 243 0042 international 1...

Page 2: ...Display Power The TV2 display is powered via a USB cable from a computer or the wall plug An optional DC connector is also available which will accept 5 30 volt dc Backup batteries AA are installed in...

Page 3: ...Sensor Setup pg 6 Setting the Alarms pg 7 Installation Tips pg 8 TV2 Status Screen pg 9 LED Reset controls pg 10 Navigating with Easy Touch pg 10 Main Menu pg 12 Operational Modes pg 14 Main Mode pg 1...

Page 4: ...you ordered the TV2 for a replacement Sensor types used by the TV2 ID Type of sensor Range Accuracy Temperature Only Digital Sensor Digital wired 20 C to 75 C 0 3 C Thermistor sensors Wired or Wirele...

Page 5: ...D MM YY or YY MM DD and then Enter The date format defaults to the US style MM DD YY 4 Set the day month year hour and minute in the appropriate field by scrolling through the possible values with Up...

Page 6: ...elect the type of averaging with UP or Down and touch Enter There are three possible selections a Fast no averaging occurs The exact measurement at the time of sampling will be stored and displayed No...

Page 7: ...et it for at least 00 30 30 seconds but not longer than 06 00 Six minutes B Scroll in the upper alarm limit and delay time and then the lower alarm limit and delay with Up and Down touching Enter to m...

Page 8: ...log and initiating email alerts if alarms occur 4 Backup Battery Three AA batteries are installed in the display unit to provide temporary power during a power outage If a power outage occurs the disp...

Page 9: ...by touching various hot spots For example 1 Touch a temperature to see the history chart for that sensor 2 Touch a Max Min area to reset it 3 Touch Main Menu to set or change various settings such as...

Page 10: ...t it is collecting and storing temperatures from the sensors The Red LED blinks when the display is operating on batteries If an alarm occurs it will glow a steady red The small hole on the left of th...

Page 11: ...Two Dimensional Instruments LLC P O Box 159 Crestwood KY 40014 877 241 0042 502 243 0039 fax 502 243 0042 international 11 Touch Main Menu to change settings Touch a Max Min temperature to reset it...

Page 12: ...877 241 0042 502 243 0039 fax 502 243 0042 international 12 The Main Menu Touch Main Menu at the bottom of the Status Screen to enter the menu system When the Main Menu opens the System Setup field w...

Page 13: ...Right will move the highlight to the first item on the page 2 Once the field is highlighted change the value by touching Up or Down Appropriate values will be scrolled through Note The longer you tou...

Page 14: ...letters The max min readings are also shown in green unless one of the temperatures violated an alarm limit in which case it will be in red Note It is possible a max or min temperature was too high or...

Page 15: ...will change if you scroll left or right or zoom out or in to view additional data 4 The bottom two rows of the display show the current day and time along with the most recent reading from each senso...

Page 16: ...blue triangle doubles the amount of data displayed on the chart see zoom in FAQ The top blue triangle zooms into the display so less data is displayed The green triangle on the left scrolls backward...

Page 17: ...e will move the white vertical line back and forth to highlight individual temperatures The temperature beneath the vertical line is shown along with the day and time it was taken at the bottom of the...

Page 18: ...and perform all other functions during the sleep mode TV2 can be awakened for twenty seconds by touching the screen 2 The TV2 operates normally while running on batteries except that it is not as bri...

Page 19: ...43 0042 international 19 Calibrating sensors To calibrate a sensor access the sensor setup menu by touching Main Menu and Right until the sensor setup area is highlighted Touch Left to highlight Calib...

Page 20: ...lue is what it should be reading If the measured value needs to be adjusted to agree with your comparison thermometer move to that field and touch Up or Down to scroll in the correct value How TV2 use...

Page 21: ...039 fax 502 243 0042 international 21 TView Software Copying data from the display Downloading or copying data from a TV2 to a computer is done via the USB cable If you are powering your display with...

Page 22: ...Make sure you have rights to do so You will also be given an opportunity to install the software in a directory other than the default directory We recommend that you accept the default directory 6 O...

Page 23: ...ant TView continues to scan for TV2s asking for you to name each until it found them all If you have other devices using serial ports that you do not want the software to scan you can select the setup...

Page 24: ...rt you will be asked if you want to replace the existing data If you answer yes the displayed chart will be erased If you do not want to erase the data click no and save the existing data before downl...

Page 25: ...an rename this by double clicking on the tab and typing a description in the text box This will rename the chart and the tab 2 You can position the mouse cursor on any point of the curve to see the va...

Page 26: ...he active chart to your computer The saved chart will be encrypted and have a TXV suffix It is encrypted with the username and password you entered when the program was opened iv Export Chart to XLS T...

Page 27: ...ct the TV2 to be downloaded by clicking Add New Device and clicking on the one you want 2 Highlight the sensors you want included in the Download 3 Type in the file name and specify the location on yo...

Page 28: ...you use the file to update a TV2 which has a different serial number it could cause the TV2 to stop working If this occurs you must return it to 2di for reprogramming c View tab To view alarm settings...

Page 29: ...ttached to that TV2 Select one of them by clicking on it The last 100 readings will be displayed in the chart along with the current temperature You can add additional sensors to this page Clicking th...

Page 30: ...ew Diagnostics Menu will be used when requested by a 2di technician All activity of the TView software is archived You have the option of saving this information to be emailed to a 2di 4 TView Communi...

Page 31: ...How can I tell if the sensors are linked to the TV2 If the display shows a temperature that sensor is linked to the base station If it is not linked a message indicating that will be displayed instea...

Page 32: ...ated For example sensors placed in a refrigerator will have much less battery life Note Use an Alkaline battery Not a Lithium battery which can cause unexpected results b The battery charge of the sen...

Page 33: ...data points to appear in each column The data on the TV2 can be zoomed out 10 times Zoom 10X This means that the user can see between 4 months and 256 years on one chart depending on how often the sen...

Page 34: ...to measure room or refrigerator temperature and humidity c Exterior thermistor A thermistor on a wire is plugged into the black transmitter This is the same type of thermistor used for the wireless i...

Page 35: ...repositioned and power supplied touch the screen and it will reboot Your previously collected data will still be there and will display properly 15 How do I change the TV2 batteries The TV2 batteries...

Page 36: ...been changed to be upgraded in the field In this case the TV2 display must be returned to Two Dimensional Instruments LLC for reprogramming for which service additional charges may be incurred Discla...

Page 37: ...Any freight charges incurred may at the factory s option be passed on to the user This warranty does not cover routine calibration or battery replacement The forgoing warranty and remedy are exclusive...

Page 38: ...l device pursuant to Part 15 of the FCC Rules This equipment conforms with the Australian and New Zealand EMC requirement for generic products to be used in residential commercial and light industrial...

Reviews: