background image

106 Industrial Installation Manual  Rev. A-1 

WARRANTY STATEMENT 

 
2B  Technologies  warrants  its  products  against  defects  in  materials  and  workmanship.  
2B Technologies will, at its option, repair or replace products that prove to be defective.  
The  warranty  set  forth  is  exclusive  and  no  other  warranty,  whether  written  or  oral,  is 
expressed or implied.  2B Technologies specifically disclaims the implied warranties of 
merchantability and fitness for a particular purpose. 

 

Warranty Periods 

 

The  warranty  period  is  one  (1)  year  from  date  of  receipt  by  the  purchaser,  but  in  no 
event more than thirteen (13) months from original invoice date from 2B Technologies. 

 

Warranty Service 

 

Warranty  Service  is  provided  to  customers  through  phone  support,  Monday  -  Friday, 
from  9:00 a.m.  to  5:00  p.m.,  Mountain  Time  USA,  or  by  submission  of  a tech  support 
ticket  at 

www.twobtech.com/techsupport

.  Phone  support  is  for  trouble-shooting  and 

determination of parts to be shipped from 2B Technologies to the customer in order to 
return  the  product  to  operation  within  stated  specifications.    If  phone  support  is  not 
efficient  and  effective,  the  product  may  be  returned  to  2B  Technologies  for  repair  or 
replacement. Prior to returning the product, a Repair Authorization Number (RA) must 
be obtained from the 2B Technologies Service Department. 

 

Shipping 

 

2B Technologies will pay freight charges for replacement or repaired products shipped 
to  the  customer  site.  Customers  shall  pay  freight  charges  for  all  products  returning  to 
2B Technologies. 

 

Conditions 

 

The  foregoing  warranty  shall  not  apply  to  defects  resulting  from  improper  or  inadequate 
maintenance,  adjustment,  calibration, or operation by  the  customer.   Usage of maintenance 
materials purchased from suppliers other than 2B Technologies will void this warranty. 

 

Limitation of Remedies and Liability 

 

The remedies provided herein are the Customer's sole and exclusive remedies.  In no 
event  shall  2B  Technologies  be  liable  for  direct,  indirect,  special,  incidental  or 
consequential damages (including loss of profits) whether based on contract, tort or any 
other  legal  theory.    The  Industrial  Enclosure  Installation  Manual  is  believed  to  be 
accurate at the time of publication and no responsibility is taken for any errors that may 
be present.  In no event shall 2B Technologies be liable for incidental or consequential 
damages  in  connection  with  or  arising  from  the  use  of  the  Industrial  Enclosure 
Installation Manual and its accompanying related materials.  Warranty  is valid only for 
the country designated on the 2B Technologies quote or invoice. 

Summary of Contents for 106

Page 1: ... 1 i Industrial Enclosures For Model 106 Ozone Monitors 2B Technologies DRAWINGS AND INSTALLATION MANUAL Copyright 2020 2B Technologies All rights reserved Technical Support www twobtech com techsupport techsupport twobtech com 1 303 273 0559 ...

Page 2: ...nts IDENTIFICATION RECORDS iii PRINTING HISTORY iv WARRANTY STATEMENT v WARNINGS vi 1 INTRODUCTION 1 2 INSTALLATION 1 2 1 Mounting 1 2 2 Power 1 2 3 Inlet Manifold 2 2 4 Analog Output Serial Communication and Relays 5 3 GAS CONNECTIONS 8 4 MAINTENANCE 8 ...

Page 3: ...Manual Rev A 1 iii IDENTIFICATION RECORDS Record the following information for future reference Unit serial number ______________________________________ Warranty start date _______________________________________ date of receipt ...

Page 4: ...ust 2020 TRADEMARKS PATENTS 2B Technologies 2B Tech and 2B are trademarks of 2B Technologies CONFIDENTIALITY The information contained in this manual may be confidential and proprietary and is the property of 2B Technologies Information disclosed herein shall not be used to manufacture construct or otherwise reproduce the goods disclosed herein The information disclosed herein shall not be disclos...

Page 5: ... Prior to returning the product a Repair Authorization Number RA must be obtained from the 2B Technologies Service Department Shipping 2B Technologies will pay freight charges for replacement or repaired products shipped to the customer site Customers shall pay freight charges for all products returning to 2B Technologies Conditions The foregoing warranty shall not apply to defects resulting from ...

Page 6: ...WEIS Vor dem Öffnen des Gerätes Netzstecker ziehen WARNHINWEIS Dieses auf dem Gerät weist darauf hin dab der Anwender zuerst das entsprechende Kapitel in der Bedienungsanleitung lesen sollte WARNHINWEIS Wenn das Gerät nicht wie durch die Firma 2B Technologies USA vorgeschrieben und im Handbuch beschrieben betrieben wird können die im Gerät eingebauten Schutzvorrichtungen beeinträchtigt werden ITAL...

Page 7: ...Industrial Enclosure be mounted on a wall or specially built stand The enclosure weighs over 14 pounds with the ozone monitor installed and requires a substantial mounting structure The floor of the box should be level when the box is mounted The figures in this manual provide mechanical dimensions for the Industrial Enclosure 2 1 Mounting The back of the enclosure has three holes at the top and t...

Page 8: ...Multichannel 3 port Three gas inlets option available when ordering Multichannel 6 port Six gas inlets option available when ordering The size of the Industrial Enclosure is the same for all three configurations Figure 2a in this manual shows each configuration Figure 1 Industrial Enclosure Dimensions Front View of standard single port configuration ...

Page 9: ...l Rev A 1 3 Figure 2a Industrial Enclosure Bottom View of standard single 3 and 6 port configurations Figure 2b Industrial Enclosure Dimensions Bottom View of standard single port configuration Inlets Inlet Outlet Outlet Outlet Inlets ...

Page 10: ...106 Industrial Installation Manual Rev A 1 4 Figure 3 Industrial Enclosure Dimensions Bottom View with Door Clearance ...

Page 11: ...e analog output serial communication and relays is on the inside of the enclosure Figure 4 The connections are made to the 8 position and 12 position terminal blocks according to Figure 4 and Tables 1 and 2 below Photos of the connections are shown in Figure 5 Figure 4 Connections to the Industrial Enclosure ...

Page 12: ...DC White 7 open 8 open Table 2 12 Position Terminal Block Connections Relays Pin Description Wire Color 1 Relay 1 open on alarm condition Red 2 Relay 1 ground Black 3 Relay 1 closed on alarm condition Green 4 Relay 2 open on alarm condition Red 5 Relay 2 ground Black 6 Relay 2 closed on alarm condition Blue 7 Relay 3 open on alarm condition Red 8 Relay 3 ground Black 9 Relay 3 closed on alarm cond...

Page 13: ...106 Industrial Installation Manual Rev A 1 7 Figure 5 Photos of Terminal Connections ...

Page 14: ...SERVICE CONSULT WITH 2B TECHNOLOGIES FOR ADVICE ON MATERIALS CAUTION EXPOSURE TO OZONE IS HAZARDOUS ENSURE THAT ALL GAS CONNECTIONS ARE TIGHT AND THAT NO LEAKS EXIST 4 MAINTENANCE The Industrial enclosure requires minimum maintenance Inspect the enclosure for signs of leaks or damage Clean the polyester surface with an appropriate cleaner CAUTION Do not use abrasive cleaners on the window For the ...

Reviews: