Copyright 1010music LLC 2023
Page 32 of 123
Blackbox 3.0 User Manual
Parameter
Description
Range of Values
Mod
Target?
Loop Fade
The amount of cross-fading that will be applied
when transitioning from the end to the
beginning of the loop. This parameter is only
active when Loop Mode is Forward. This is a
percentage of the loop length. The Loop Start
point must be greater than zero for this to work.
Blackbox will use a copy of the WAV signal from
just before the Loop Start point that is of a
length of the loop fade of the loop length. It will
then fade in that signal so that it ends just at the
Loop End point. In this way, you can smooth out
the transition at the loop point.
0
to
100%
No
Reverse
When Reverse is ON, the WAV file will play in
reverse.
ON
,
OFF
No
Start
Point where playback will begin when playing
forward or ends when playing in reverse.
Expressed as the number of the sample to be
played first.
0
to number of samples in the
file
Yes
Length
When Loop Mode is None, how long the sample
will play past the value of the Start parameter.
Expressed in number of samples.
0
to number of samples in the
file
Yes
Loop Start
Point where the looping will begin when
playing forward, or looping will end when
playing in reverse. Expressed as a sample
number. Must be before or equal to LpEnd.
LpStr is read from the WAV file when sample is
loaded, and saved to the WAV file when the
WAV is saved.
0
to number of samples in the
file
Yes
Loop End
Point where the looping will end when playing
forward, or looping will begin when playing in
reverse. Expressed as a sample number. Must be
after or equal to LpStr.
LpEnd is read form the WAV file when a sample
is loaded, and saved to the WAV file when the
WAV is saved.
Loop Start
to number of
samples in the file
Yes
Pos Pad
Parameters
Page for Sample
Mode