etc. 

 

Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, 

light etc.

Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall 

plants etc.

 

 
 
 
 
 
 

CONNECTION: 

 

 
 

Warning. Danger of death through electric shock! 

 

Must be installed by professional electrician.

Disconnect power source.

Cover or shied any adjacent live components.

Ensure device cannot be switched on.

Check power supply is disconnected.


Unload the cover directly.

Connect the power and the load into the connection-wire column of the 

sensor according to connection-wire diagram.

Fix the sensor on the selected position with the inflated screw as the 

figure on the right.

Install back the cover and then you can test it.

  

CONNECTION-WIRE DIAGRAM: 

 

(See the right figure) 

 

TEST: 

 

 

Turn  the  TIME  knob  anti-clockwise  on  the  minimum  (10s). 

Turn the LUX knob clockwise on the maximum

(sun). 

Switch on the power; the sensor and its connected lamp will have 

no signal at the beginning. After Warm-up 30sec, the sensor 

can  start  work  .If  the  sensor  receives  the  induction  signal, 

the lamp will turn on. While there is no

another induction signal any more, the load should stop working within 10sec

±

3sec and 

the lamp would turn off. 

Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the 

sensor would not work and the lamp stop working too. If you cover the detection window 

with  the  opaque  objects  (towel  etc),  the  sensor  would  work  .Under  no  induction  signal 

condition, the sensor should stop working within 10sec

±

3sec.

 

Note: when testing in daylight, please turn LUX knob to

 (SUN) position, otherwise 

 

the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp 

 

and sensor should be 60cm at least. 

 

SOME PROBLEM AND SOLVED WAY: 

 

The load do not work:

Please check if the connection-wiring of power and load is correct. 

 

Please check if the load is good. 

 

Please check if the working light sets correspond to ambient light. 

 
The sensitivity is poor:

Please check if there has any hindrance in front of the detection window to affect to 

receive the signal. 

 

Please check if the ambient temperature is too high. 

 

Please check if the induction signal source is in the detection fields. 

 

Please check if the installation height corresponds to the height showed in the 

instruction. 

 

Please check if the moving orientation is correct. 

 
The sensor can not shut off the load automatically:

Please check if there is continual signal in the detection field. 

 

Please check if the time delay is the longest. 

 

Please check if the power corresponds to the instruction. 

 
 
 

 