background image

ZANUSSI

P R O F E S S I O N A L

ACTIVE BLAST CHILLERS

120-180 KG 20 GN 2/1

1 SINGLE SENSOR PROBE C/FREEZER

1

1

1

1

1

1

1

INCLUDED ACCESSORIES

Disassembled

l

l

Power supply - V, phases, Hz

400 V, 3N, 50

400 V, 3N, 50

400 V, 3N, 50

400 V, 3N, 50

400 V, 3N, 50

400 V, 3N, 50

400 V, 3N, 50

Net weight - kg.

300

180

605

438

438

180

605

    installed-electric

6.515

1.83

8.33

1.735

1.735

1.735

8.335

Power - kW

    at evaporation temperature - °C

-10

-10

-10

-10

-10

-10

Refrigerant power

Refrigeration power - W

11100

20200

20200

20200

20200

20200

Refrigerant type

R404a

R404a

R404a; 

R404a; 

R404a; 

R404a; 

R404a; 

N° defrost in 24 hrs.

4/20'

4/20'

4/20'

4/20'

4/20'

4/20'

4/20'

Compressor power - HP

4

7.5

minimum 7,5; 

7,5; 

Max load capacity - trays h 65 mm - n°

20

20

20

20

Trays type

600x400; GN 2/1

600x400; GN 2/1

600x400; GN 2/1

600x400; GN 2/1

600x400; GN 2/1

600x400; GN 2/1

600x400; GN 2/1

Door hinges

Right Side

Right Side

Right Side

Right Side

Right Side

Right Side

Right Side

N° and type of door

1

1

1; 

1; 

2; 

1; 

1; 

    height

1850

1850

1850

1850

1850

1850

1850

    depth

920

920

946

946

946

946

946

    width

772

772

752

752

752

752

752

Internal dimensions - mm

    height

2470

2470

2471

2230

2230

2230

2471

    depth/with open doors

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

    width

1400

1400

1400

1400

1400

1400

1400

External dimensions - mm

Cooling unit

Built-In

Remote

Built-In

Remote

Remote

Remote

Built-In

    UK Guide lines - chilling / freezing

120

120

180

180

180

180

180

    NF Regulations - chilling / freezing

144

144

144

144

144

Productivity per cycle - kg.

BC120A

110089

BC120RA

110090

BC180A

110005

BC180RA

110007

BC180RPA

110009

BC180RDA

110008

BC180DA

110006

CHARACTERISTICS

MODELS

TECHNICAL DATA

RANGE 
COMPOSITION

Chilling means bringing the 
temperature of cooked food from 
+90ºC to +3°C in a short time lap to 
minimize bacteria proliferation and 
avoid loss of food consistency and 
texture. The ZANUSSI easyChill 
Blast Chillers reduce temperature to 
+3°C at food core in less than 90 
minutes. After the Blast Chilling a 
holding cycle starts automatically to 
maintain food at +3°C. Blast chilled 
food has a solid 5 days shelf life 
without loss of flavour, nutritional 
values and weight. The opportunity 
to prepare in a single shot the food 
to be used in different times during 
the week enables a better work 
scheduling and therefore a sensible 
reduction in labour costs.

FUNCTIONAL AND 
CONSTRUCTION 
FEATURES

 

Soft Chilling (Air temperature 

–2°C). 

 

Hard Chilling (Air temperature 

–12°C). 

 

All the probe-driven cycles feature 

ARTE (Algorithm for Remaining 
Time Estimation): the machine 
displays the actual time needed to 
end the cycle and to make planning 
the activities easier. 

 

Holding at +3°C (automatically 

activated at the end of each cycle). 

 

Turbo cooling: the chiller works 

continuously at the desired 
temperature. Ideal for continuous 
production and for pastry application. 

Summary of Contents for ZANUSSI easyChill 110005

Page 1: ...nit Built In Remote Built In Remote Remote Remote Built In UK Guide lines chilling freezing 120 120 180 180 180 180 180 NF Regulations chilling freezing 144 144 144 144 144 Productivity per cycle kg BC120A 110089 BC120RA 110090 BC180A 110005 BC180RA 110007 BC180RPA 110009 BC180RDA 110008 BC180DA 110006 CHARACTERISTICS MODELS TECHNICAL DATA RANGE COMPOSITION Chilling means bringing the temperature ...

Page 2: ...10006 ACCESSORIES MODELS OPTIONAL ACCESSORIES Single sensor core probe as standard Automatic recognition of the insertion of the food probe cycles piloted either by food probe temperature or by time The control unit provides several operating settings time core temperature according to NF and UK regulations time air temperature probe personalised according to national regulations sterilizing cycle...

Page 3: ... without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L WOC Cooling water outlet l l l Q Appliance lifting connection l l EI Electrical connection 400 V 3N 50 400 V 3N 50 400 V 3N 50 D Water drain 3 4 3 4 CWI Cold water inlet 1 1 BC120A 110089 BC180A 110005 BC180DA 110006 LEGEND 110089 110006 110005 ...

Page 4: ...r notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L RI Remote refrigeration connection l l l Q Appliance lifting connection l l EI Electrical connection 400 V 3N 50 400 V 3N 50 400 V 3N 50 ED Remote electrical connection l l l D Water drain 3 4 3 4 BC120RA 110090 BC180RA 110007 BC180RDA 110008 LEGEND 110090 110008 110007 ...

Page 5: ... the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L RI Remote refrigeration connection l EI Electrical connection 400 V 3N 50 ED Remote electrical connection l D Water drain 3 4 BC180RPA 110009 LEGEND 110009 ...

Reviews: