background image

Owner’s manual

mLAN Interface Card

MY8-mLAN

Bedienungsanleitung

Mode d’emploi

Manual de instrucciones

English

Deutsch

Français

Español

Summary of Contents for MY8-mLAN

Page 1: ...Owner s manual mLAN Interface Card MY8 mLAN Bedienungsanleitung Mode d emploi Manual de instrucciones English Deutsch Français Español ...

Page 2: ...hock hazard CAUTION Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others or damage to the instrument or other property These precautions include but are not limited to the following The card is sensitive to static electricity Before handling the card you should briefly touch the metal casing of the main unit with your bare hand to discharge ...

Page 3: ...er s manual this document mLAN guidebook mLAN Tools installation guide About the included CD ROM The included CD ROM contains software that is useful when used in conjunction with the MY8 mLAN This software includes mLAN Patchbay which lets you make settings on your computer to specify the routing of audio MIDI signals between mLAN devices con nected to the MY8 mLAN For details refer to the separa...

Page 4: ... How to install the MY8 mLAN 5 Names and Functions 6 DIP switch SW1 settings 7 Connections 10 About mLAN connections 11 Internal Configuration of the MY8 mLAN 12 LED Messages 13 Specifications 14 English MY8 E book Page 4 Thursday October 11 2001 10 05 AM ...

Page 5: ...necting the main unit to other devices Leaving the power cord connected while working can result in electric shock Leaving other cables connected can interfere with the installation procedure It is recommended that you wear gloves to protect your hands from sharp or pointed projec tions on the equipment Board components may be damaged by electrostatic discharge Be sure to drain any electro static ...

Page 6: ...rupted B RT ERR LED This LED indicates the following statuses green The MY8 mLAN is a root node orange An IEEE 1394 bus related error has occurred red Another type of error has occurred off Normal operating condition other than the above Refer to LED Messages on page 13 for information on the error indication C ACTIVE LED This LED indicates the following statuses blue The relay function between mL...

Page 7: ...MIDI INPUT Plug OUTPUT Plug ON enables OFF disables This specifies whether the MIDI input output plugs will be enabled or disabled If this is ON one MIDI output plug and one MIDI input plug will be enabled If this is OFF the MIDI plugs will be disabled MY8 mLAN number This specifies the number of the module name When you are using multiple MY8 mLAN units together use these ON OFF switches to spec ...

Page 8: ...situation Number Module name displayed for connection setting OFF OFF OFF OFF OFF Do not use this setting ON OFF OFF OFF OFF 1 MYmLAN01 factory setting OFF ON OFF OFF OFF 2 MYmLAN02 ON ON OFF OFF OFF 3 MYmLAN03 OFF OFF ON OFF OFF 4 MYmLAN04 ON OFF ON OFF OFF 5 MYmLAN05 OFF ON ON OFF OFF 6 MYmLAN06 ON ON ON OFF OFF 7 MYmLAN07 OFF OFF OFF ON OFF 8 MYmLAN08 ON OFF OFF ON OFF 9 MYmLAN09 OFF ON OFF ON ...

Page 9: ...ot 1 Slot 1 transmits receives audio data to from other devices on the mLAN bus It does not trans mit or receive MIDI data Thus for the MY mLAN installed in slot 1 the audio output plugs and audio input plugs are valid and the MIDI plugs are invalid Set the DIP switches as follows 1 ON 2 ON 3 OFF 4 8 may be set as desired However be sure not to turn all of them OFF When installed in slot 2 Slot 2 ...

Page 10: ... 1394 connector of the other mLAN IEEE 1394 device When doing so it is not necessary to turn off the power of the mLAN IEEE 1394 device or the host device in which the MY8 mLAN is installed CAUTION Do not insert or remove the MY8 mLAN while the power of the host device is turned on mLAN IEEE1394 device IEEE1394 standard cable IEEE1394 standard cable Macintosh computer that supports FireWire MY8 mL...

Page 11: ...evice such as the mLAN8P or a synthesizer in which the mLAN option is installed The type of system in which the MY8 mLAN is being used will determine which of the above three methods you use to make settings For each MY8 mLAN unit eight channels of audio and one set of MIDI signals can be input and output When making mLAN connection settings these audio and MIDI inputs and outputs are handled as p...

Page 12: ... mLAN jacks1 2 MY8 mLAN mLAN audio input mLAN MIDI IN mLAN audio Audio direct conversion Audio mLAN audio direct conversion mLAN audio output mLAN MIDI OUT AW4426 01V etc OPTION I O slot MIDI mLAN MIDI conversion mLAN MIDI MIDI conversion non mLAN signals mLAN signals mLAN cables MY8 E book Page 12 Thursday October 11 2001 10 05 AM ...

Page 13: ...s a loop Check to see if any part of the connection creates a loop red orange Cycle Start Packet is not transmitted to the bus Audio MIDI data cannot be transmitted Remove the malfunctioning device red red orange A malfunctioning device exists on the bus Remove the malfunctioning device green orange The number of hops exceeds 16 Check the number of hops green orange The power to the bus is insuffi...

Page 14: ...1394 1 2 Rear OPTION I O slot connector Display mLAN 1 2 LED ACTIVE LED RT Root ERR Error LED Power consumption 2 2 W 440 mA 5 V Specifications and descriptions in this owner s manual are for information purposes only Yamaha Corp reserves the right to change or modify products or specifications at any time without prior notice Since specifications equipment or options may not be the same in every ...

Page 15: ...15 English MEMO MY8 E book Page 15 Thursday October 11 2001 10 05 AM ...

Page 16: ...16 English MEMO MY8 E book Page 16 Thursday October 11 2001 10 05 AM ...

Page 17: ...rimé sur du papier recyclé non blanchi au chlore Este documento se ha impreso reciclado en papel sin cloro alguno YAMAHA CORPORATION Pro Audio Digital Musical Instrument Division P O Box 3 Hamamatsu 430 8651 Japan 2001 Yamaha Corporation V000000 010APAP2 2 02A0 Printed in Japan MY8 Hyo4 fm Page 13 Thursday September 20 2001 9 26 AM ...