background image

BATHROOM VENTILATOR 

OPERATION MANUAL 

HB10813 

Please read this Operation Manual carefully before using this machine. 

Warning: In order to prevent damage or accident, this machine must be installed by those 
qualified technicians recognized by the government. 

Summary of Contents for HB10813

Page 1: ...TION MANUAL HB10813 Please read this Operation Manual carefully before using this machine Warning In order to prevent damage or accident this machine must be installed by those qualified technicians recognized by the government ...

Page 2: ...r and manufacturer s replacement Make sure the power wire places on suitable location and will not block the road WARNING In order to avoid overheating do not cover the heater The heater must not be located immediately below a socket outlet Do not use this heater in the surroundings of a bath a shower or a swimming pool Product do not control room temperature when there is no responsible person cl...

Page 3: ...ent This product must be connected to the ground wire Incorrect connection to the ground wire may cause danger Please check the reliability of the ground wire connection and do not use your own power wire If your plug does not match this machine please ask qualified electrician for the acceptable outlet z Follow all the safety precautions listed below for safety and to reduce the risk of injury or...

Page 4: ...e It may influence the children s health Please don t touch the plug by wet hands Please don t put the wood or metal stick into the air inlet or outlet It may lead to electric shock or product damage Do not use it on outdoor areas This appliance is for household use only Do not immerse the appliance or the electrical cord or plug in liquids Do not use the appliance for any purpose not expressly sp...

Page 5: ...rly and inform customer service center Dispose of packaging properly The heater only for personal use not for heating any liquids or other danger things Persons including children with reduced physical sensory or mental capabilities or any individual lacking experience and knowledge should be supervised or given instruction by a person responsible for their safety when they using this appliance Un...

Page 6: ...on and maintenance should be done by professional designated by the manufacturer z Please install a complete power cutoff switcher refer to below diagram which the contact separation is more than 3mm and the capacity is more than 250V 16A to control the power of the machine and install the switcher outside the bathroom where it is easily controlled z Do not install the machine in steam sauna bathr...

Page 7: ... 6 澬Names of the device and functions澭 1 Machine Unit mm Front Side Bottom Remote Control 1 Pre Filter Carbon Filter 3 Display Panel 5 Stainless Steel Housing 2 Front Panel 4 Air Outlet ʓ ʔ ʖ ʕ ʒ ...

Page 8: ... 7 2 Remote LCD Display LCD Function Display Dry 䓓ԅਈ Heat 㾎ԅਈ Vent 㠹㾎 㠹㾎 ڍ Ҡԅਈ Fan ڲ 䝬梏ԅਈ Quick Heat ବ ԅਈ 24H Vent 24 ش 㩌㠹㾎ԅਈ Time Display Swing Battery Replacement 6th Sense Air Volume Hi Lo Ѻ Ionizer ...

Page 9: ...must use the waterproof glue for the waterproof 3 This product can be installed on a window with a frame width of 294mm or above In the left side it is suggested to reserve a distance of minimum 10mm between the product and the wall In the right side please reserve a distance of minimum 30mm between the product and the wall for the ease of filter installation 9ZGOTRKYY 9ZKKR U YOTM GRR Stainless S...

Page 10: ...3 Fix the remote control holder to the designed place and make marks according to the arrows 4 Dig holes according to the mark fill the holes with 2 plastic plugs and fix the holder with screws 5 Install two R03 AAA batteries to the remote control A Rotate the knob clockwise to the position ͺ B Open the battery coverͺ C Install two R03 AAA batteries to the remote controlͺ pay attention to the dire...

Page 11: ...f 2 hrs 24 hrs 3 Dry Hi Drying High Speed On 4 hrs 12 hrs Dry Lo Low Speed On 4 hrs 12 hrs 4 Fan Hi Bathroom Cooling High Speed Off 4 hrs 24 hrs Fan Lo Low Speed Off 4 hrs 24 hrs 5 6th Sense De odor Intelligence Auto Deodorization Determine the faŶ speed by the odor sensor Off 2 hrs 24 hrs 6 Others 24H Vent Air Exhaust Low Speed Off 24 hrs Delay Vent Low Speed Off 15 mins Swing Blade Swing Up down...

Page 12: ...s over the LCD Quick Heat and time display would disappear and the machine will stop automatically z When the heater stops running the fan will continue run 25 seconds to cool down the heater HEAT Function Hi Lo z Press the Heat button the LCD displays Heat icon air volume will run at High mode Press the button again to select Hi or Lo mode z Timer the default time is 2 hrs By pressing Timer up or...

Page 13: ...s The time counter will be displayed on the LCD The time selected will be recorded in memory when it is off and will resume in your next usage z Under the mode the inter change of the air volume between Hi or Lo will not affect the time counting z Stop when press the Stop button or the pre set time runs over the LCD Dry and the time display would disappear and the machine will stop automatically z...

Page 14: ...e air volume will run at Lo mode The default running time is 24 hrs z Stop when press the Stop button or the default time runs over the LCD 24H Vent and the time display would disappear and the machine will stop automatically Delay Vent Function z Start press the Delay Vent button the LCD displays Vent icon the air volume will run at Lo mode The default running time is 15 mins z Stop when press th...

Page 15: ...irflow Ionizer Function z When the fan motor is running press the Ionizer button the LCD will display icon Ionizer function is not valid under the modes of Vent 24H Vent Delay Vent and 6th Sense z Stop when Ionizer is running press the Ionizer button Ionizer will stop and the LCD icon would disappear Press the Ionizer button again Ionizer will turn on again and the LCD will display icon as well ...

Page 16: ...water Please make sure the filter is completely dried out before putting back to the machine It is recommended to clean the filter regularly to ensure its efficiency B Carbon Filter ӑ Need to replace the carbon filter after usage for some time In general it is recommended to replace the filter for every 3 months usage but the actual replacement is subject to the frequency of usage and air quality ...

Page 17: ...electricity and ask qualified electrical engineering contractor for repair or check Self repair by user is strictly prohibited to avoid danger ӑ Turn on the power the fan does not start ӑ The power on and off ӑ Abnormal sound and vibration during operation ӑ Plastic smell or other abnormal smell occurs General Failure Treatment Phenomenon Check Solution No operate when the power turning on No powe...

Page 18: ...No HB10813 Voltage V 220 240V Frequency Hz 50Hz Power W 1350W Product Size H x W x D mm 254 x 254 x 197 Product Size excl panel H x W mm 209 x 207 Net Weight kg 3 5 z Be aware that any change of the specification and design will not be informed z If any item in the English Version is different from the Chinese Version please refer to the Chinese Version z The latest operation manual will be based ...

Reviews: