background image

Summary of Contents for 50

Page 1: ...ICE MAKER Model 50 _I i rT A i l _ T z a k P f p _ G i i Al g p c ave Ovens Compactors Room Air Conditioners Dehumidifiers Automatic Washers Clothes Dryers Freezers Refrigerator Freezers Ice Makers Oishwas ...

Page 2: ...installed above two thousand feet of altitude the bin and evaporator thermostats must be adjusted to a warmer setting Disconnect electricity remove thermostat and follow the directions for turn ing the altitude adjustment screw as shown in the label on each thermostat Shipboard operation When this ice cube maker is installed aboard a ship it will be necessary to purchase and install a water deflec...

Page 3: ...llation should be such that the cabinet can be moved forward for ser vicing if necessary Level unit 1 After placing unit in position check to make certain the unit is level side to side and front to back 2 Accurate leveling is essential for proper operation 3 Unit should be shimmed so that it is solid as well as level The shims should be of hard permanent type material such as masonite 4 If requir...

Page 4: ...drain tube Condensate pump 1 When drain connection below the level of the unit is not available a condensate pump may be used to lift the water to an available drain 2 Install condensate pump on floor behind ice maker with discharge tube to the rear Run bin drain directly into pump as shown in the illustration NOTE Electric connection to condensate pump should be from a circuit that remains energi...

Page 5: ...CLE NG NDING POWER SUPPLY CORD Alternate grounding method DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUND PRONG If changing and properly grounding the wall receptacle is impossible and where local codes permit consult your electrical inspector a temporary adapter may be plugged into the existing 2 prong wall receptacle to mate with the 3 prong power supply cord See Figure 7 THIS...

Page 6: ...oduced This means that higher operating temperatures will result in reduced ice production The unit will shut off when ice in the storage bin touches the bin thermostat well and will automatical ly cycle to keep the bin full The storage bin is not refrigerated and some meltage will occur This too varies wrth the room temperature The unit needs good air circulation to perform effi ciently Keep the ...

Page 7: ...n so until the evaporator reaches 38 2OF DANGER ELECTRIC SHOCK HAZARD disconnect power before servicing unit Maximum fuse size 15 amps r _____ 1 CUBELET CUTTER GRIDS Y CUBE CUTTER GRID d1 x 1 CubeGrid Check operation fl Start the unit by turning the service switch to ON and opening the line water valve fl NOTE Left is OFF Middle is ON Right is CLEAN In CLEAN position only the pump operates fl Chec...

Page 8: ...al 800 632 2243 from Alaska or Hawaii dial 800 253 1121 Dial just as you normally dial long distance A special operator will tell you the name and number of Your nearest Whirlpool TECH CARE service outlet During normal working hours Whirlpool consultants at this same number will also answer any questions about operating or maintaining your appliance not covered in your Use and Care Guide Learn the...

Reviews: