INSTALLATION MANUAL

INTELLIGENT SERVER

CONTENTS

Precautions for Safety .................................................................................................................... 1
Before Installation .......................................................................................................................... 1
Intelligent Server Specifications ................................................................................................... 2
1 CF (Compact Flash) card Installation ....................................................................................... 3
2 Setting .......................................................................................................................................... 3
3 Installation .................................................................................................................................... 4
4 Cable Connection ....................................................................................................................... 6

• Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER.
• Please read this manual carefully beforehand for proper installation of the SERVER.

Summary of Contents for BMS-LSV6E

Page 1: ...ore Installation 1 Intelligent Server Specifications 2 1 CF Compact Flash card Installation 3 2 Setting 3 3 Installation 4 4 Cable Connection 6 Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER Please read this manual carefully beforehand for proper installation of the SERVER ...

Page 2: ...lt in disconnection overheating or fire When providing services perform the task after you confirm that you turned off the main power supply removed the power cord from the AC inlet and the power was off CAUTION Before Installation No 1 2 3 4 Quantity 1 1 1 2 Item INTELLIGENT SERVER Installation Manual Cable Closed end wire joint Remarks RS 485 cable for Intelligent Server No 1 2 Type Wire size Le...

Page 3: ...RUN LED Shut down switch POWER switch AC inlet AC IN Specifications Power Supply Current Operating temperature humidity Storage temperature Dimension Mass COM port LAN 220 240 VAC 50 60 Hz 0 2 A 0 to 40 C 10 to 90 RH no condensation 20 to 60 C 250 W 70 H 145 D mm 292 W including the fixing metal plate 1 5 kg RS 485 9 pin D SUB 10BASE T 100BASE TX External view 70 69 5 19 3 2 145 105 9 125 11 250 2...

Page 4: ...operly the Intelligent Server will not work REQUIREMENT Insert the CF card with the software sold separately Push the CF card fully into the slot 2 Setting CF card Rating label 1 Remove two screws and the cover plate and the CF card slot appears 2 Insert the CF card with its rating label attached surface upward Confirm the CF card is surely pushed into the slot The setting is not required S1 is se...

Page 5: ... Installation 1 Surface mount 2 Wall mount Mount the server with the front face upward AC inlet side Unit mm 4 x Ø4 6 19 6 6 21 105 280 145 Fixing screw hole positions Do not install the unit in any of the following places Humid or wet place Dusty place Place exposed to direct sunlight Place where there is a TV set or radio within one meter Place exposed to rain outdoors under eaves etc REQUIREMEN...

Page 6: ... ventilation Item Installation space Direction Top Bottom Front Rear Right side Left side Surface mount 100 0 100 50 50 1 Location adjacent to wall permitted means that the unit can be installed close to the wall on that side Maintenance Space Maintenance space is required for installation and maintenance of the unit Front INTELLIGENT SERVER 1000 1000 Maintenance Space Installation Space Unit mm R...

Page 7: ...terface TxRx Connection Connect three of the four wires of RS 485 wire red wire orange wire wire from the terminal board RS 485 A of the TCS NET Relay Interface together with the closed end wire joint The red and orange wires can be connected directly to the terminal board RS 485 A of the Relay Interface TxRx Connection Connect three of the four wires of RS 485 wire brown wire yellow wire wire fro...

Page 8: ...istered trademark of ASHRAE American Society of Heating Refrigerating and Air Conditioning Engineers Inc Compact Flash and CF are trademarks of SanDisk Corporation Ethernet is a registered trademark of Xerox Corporation EH99861301 ...