background image

Model:
BMS-STBN

E

(for Intelligent Server model BMS-LSV4E only)

INSTALLATION MANUAL

BACnet

TM

 SOFTWARE

CONTENTS

Precautions for Safety .................................................................................................................... 1
Before Installation .......................................................................................................................... 1
Elements of the Intelligent Server ................................................................................................. 2
1 CF (Compact Flash) card Installation ....................................................................................... 3
2 Setting .......................................................................................................................................... 3
3 Installation.................................................................................................................................... 4
4 Cable Connection ....................................................................................................................... 6

• Thank you very much for purchasing this TOSHIBA BACnet Software.
• Please read this manual carefully beforehand for proper installation of the software.

Summary of Contents for BMS-LSV4E

Page 1: ...tions for Safety 1 Before Installation 1 Elements of the Intelligent Server 2 1 CF Compact Flash card Installation 3 2 Setting 3 3 Installation 4 4 Cable Connection 6 Thank you very much for purchasing this TOSHIBA BACnet Software Please read this manual carefully beforehand for proper installation of the software ...

Page 2: ...heating or fire Connect the specified cables for the terminals securely to prevent external forces from affecting them Failure to do so may result in disconnection overheating or fire CAUTION Before Installation No 1 2 3 4 Quantity 1 1 2 1 Item Intelligent Server Software Cable Closed end wire joint Installation Manual Remarks Compact Flash card RS 485 cable for Intelligent Server No 1 Type Wire s...

Page 3: ...90 RH without condensation 2 45 m s2 or the less 24 5 m s2 or the less Specification of Installation Environment 1 Ambient Conditions The specification of ambient conditions is shown below Ambient Specification Storage 20 to 60 C 15 C H 10 to 90 RH without condensation 4 91 m s2 or the less 49 0 m s2 or the less Item Power Supply Grounding Rated Voltage Tolerable Range Frequency Power Consumption ...

Page 4: ...vided on the bottom board of the Intelligent Server Set the switch as follows 2 Setting If the RS 485 mode set switch is set incorrectly the Intelligent Server will not work NOTE CF Compact Flash card 1 2 3 4 Not used Note 1 Transmit data sent from the Intelligent Server is not received by the same server during transmission Note 2 Transmit data sent from the Intelligent Server is also received by...

Page 5: ...d and Orientation There are two ways to install the Intelligent Server as shown below 1 rack mount 2 surface mount The rack mount installation requires a support bracket for a 19 inch rack Please contact us if you need the support bracket 1 Rack mount A support bracket is required to be fixed to the bottom rear side of the unit 2 Surface mount Standard installation 308 4 30 8 30 8 30 133 35 Screw ...

Page 6: ...p Rear Left side Front Right side Item Installation space Direction Top Bottom Front Rear Right side Left side Rack mount 50 50 100 100 Location adjacent to wall permitted 1 Location adjacent to wall permitted 1 Surface mount 100 0 100 Location adjacent to wall permitted 1 100 100 1 Location adjacent to wall permitted means that the unit can be installed close to the wall on that side MaintenanceS...

Page 7: ... 485 wire red wire orange wire wire from the terminal board RS 485 A of the TCS NET Relay Interface together with the attached closed end wire joint The red and orange wires can be connected directly to the terminal board RS 485 A of the Relay Interface TxRx Connection Connect three of the four wires of RS 485 wire brown wire yellow wire wire from the terminal board RS 485 B of the TCS NET Relay I...

Page 8: ... and Air Conditioning Engineers Inc Compact Flash and CF are trademarks of SanDisk Corporation Ethernet is a registered trademark of Xerox Corporation Lon Talk LonWorks and Neuron are registered trademarks of Echelon Corporation in the United States and other countries Appearance and Size 370 198 39 5 CAUTION Do not remove WARNING Do not decompose Unit in mm EH99852301 ...