background image

 

 

CCTV 

SISTORE AX9/AX16 (V2.5) 

User’s Manual 

 

Fire & Security Products

Siemens Building Technologies

 

 

Summary of Contents for SISTORE AX16

Page 1: ...CCTV SISTORE AX9 AX16 V2 5 User s Manual Fire Security Products Siemens Building Technologies ...

Page 2: ...ne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden zu dem es ihm übergeben worden ist We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make t...

Page 3: ...traWide SCSI Port 18 2 12 Connecting to the Network Port 18 2 13 Connecting to the USB Port 19 2 14 Factory Reset 19 2 15 Connecting the Power Cord 20 3 Configuration 21 3 1 Front Panel Controls 21 3 1 1 Power LED 21 3 1 2 Network LED 21 3 1 3 Backup LED 21 3 1 4 Camera Buttons 1 to 16 21 3 1 5 Sequence Button 22 3 1 6 Display Button 22 3 1 7 PTZ Button 22 3 1 8 Freeze Button 22 3 1 9 Alarm Button...

Page 4: ...ion Notify Setup Screen 49 3 8 4 Motion Detector Event Action Record Setup Screen 49 3 8 5 Motion Detector Event Action Alarm Out Setup Screen 50 3 8 6 Motion Detector Event Action Notify Setup Screen 51 3 8 7 Video Loss Event Action Record Setup Screen 51 3 8 8 Video Loss Event Action Alarm Out Setup Screen 52 3 8 9 Video Loss Event Action Notify Setup Screen 53 3 9 Display Setup 54 3 9 1 OSD On ...

Page 5: ...8 5 2 Preparing the USB IDE hard disk drive in Windows 98 79 6 Appendix B Reviewing Video Clips 80 7 Appendix C Troubleshooting 82 8 Appendix D Connector Pin Outs 83 8 1 Alarm I O Connector and RS485 Connector Pin Outs 83 9 Appendix E Connection Diagram 84 9 1 Sample I Connecting the Dome Camera and SISTORE AX9 AX16 84 9 2 Sample II Connecting the External Modem and SISTORE AX RAS 84 9 3 Sample II...

Page 6: ......

Page 7: ... harmful interference in which case users will be required to correct the interference at their own expense WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This class of digital apparatus meets all requirements of the Canadian Interference causing Equipment Regulations The information in this m...

Page 8: ...unting kit approved by the manufacturer z This equipment and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the equipment and cart combination to overturn z Power Sources This equipment should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power please consult your equipment deal...

Page 9: ... Safety Check Upon completion of any service or repairs to this equipment ask the service technician to perform safety checks to determine that the equipment is in proper operating condition z Field Installation This installation should be made by a qualified service person and should conform to all local codes z Correct Batteries Warning Risk of explosion if battery is replaced by an incorrect ty...

Page 10: ... addressing this concern z Reliable Earthing Grounding Reliable grounding of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips z Cable lengths For reasons of EMC the cable used for RS232 audio In Out SCSI connections and power supply must be not any longer than 3 meters ...

Page 11: ... up to 50 PAL Images per Second 60 NTSC Images per Second z Loop Through Video Connectors z Continuous Recording in Disk Overwrite Mode z Video Archiving via Ultra SCSI Interface z Continues Recording while Archiving Transmitting to Remote Site and during Playback z User friendly Graphical User Interface GUI Menu System in Multiple Languages z Two Record Modes Time and Event z Audio Recording and ...

Page 12: ... set up for event or time lapse recording You can define times to record and the schedule can change for different days of the week and user defined holidays The DVR can be set up to alert you when the hard disk drive is full or it can be set up to record over the oldest video once the disk is full Your DVR uses a proprietary encryption scheme making it nearly impossible to alter video You can vie...

Page 13: ...r the other items that make up part of your system Fig 2 16 Channel DVR rear panel 2 3 Setting Unit for PAL or NTSC Fig 3 PAL NTSC switch Your DVR can be used with either PAL or NTSC equipment Before turning on the DVR set the switch to P PAL or N NTSC to match your equipment NOTE You cannot mix PAL and NTSC equipment For example you cannot use a PAL camera and an NTSC monitor CAUTION If you set t...

Page 14: ...connect a cable to the Loop BNC unless it is connected to another terminated device because it will cause poor quality video 2 6 Connecting the Monitor Fig 6 Video Out connectors Connect the monitor to either the Video Out or SVHS Out connector Connect the spot monitor to the SPOT connector if required NOTE If your monitor has an SVHS input use it for better quality video display NOTE The Video Ou...

Page 15: ...or directly from a microphone 2 8 Connecting Alarms Fig 8 Alarm Input Output and RS485 connector Fig 9 Alarm Input Output board and alarm connector strips An Alarm I O port DB 25 male connector is provided to connect the alarm inputs and alarm outputs Connect the wires to connectors on the Alarm I O board supplied with the unit and then connect the board to the Alarm I O port CAUTION Do not attemp...

Page 16: ...tivate external devices such as buzzers or lights Connect the device to the AO Alarm Out and GND Ground connectors AO is an active low open collector output which sinks 5 mA 12 V and 30 mA 5V See Chapter 3 Configuration for configuring alarm output 2 8 4 ARI Alarm Reset In An external signal to the Alarm Reset In can be used to reset both the Alarm Out signal and the DVR s internal buzzer Mechanic...

Page 17: ...manufacture s manual for configuring the RS485 connection 2 10 Connecting to the RS232 Port Fig 11 RS232 connector An RS232 port is provided to connect a remote control keyboard or connect an external modem for remote monitoring configuration and software upgrades Use a modem cable with a DB 9 female connector to connect to the DVR See Chapter 3 Configuration for configuring the modem NOTE The DVR...

Page 18: ... CAUTION Do NOT connect the SCSI device while the DVR power is on The DVR must be powered down to connect the SCSI device and powered up again after the SCSI device has been connected Power up the SCSI device so it is ready for operation in advance of powering up the DVR CAUTION If the SCSI device is shut down while the device is operating the DVR system may not work normally 2 12 Connecting to th...

Page 19: ...turn all the settings to the original factory settings CAUTION When using the Factory Reset you will lose any setting you have made To reset the unit you will need a straightened paperclip 1 Unplug the power to turn the DVR off 2 Plug the power to turn it on again 3 While the DVR is initializing poke the straightened paperclip in the unlabeled hole above the PAL NTSC switch 4 Hold the switch until...

Page 20: ...WARNING ROUTE POWER CORDS SO THAT THEY ARE NOT A TRIPPING HAZARD MAKE CERTAIN THE POWER CORD WILL NOT BE PINCHED OR ABRADED BY FURNITURE DO NOT INSTALL POWER CORDS UNDER RUGS OR CARPET THE POWER CORD HAS A GROUNDING PIN IF YOUR POWER OUTLET DOES NOT HAVE A GROUNDING PIN RECEPTACLE DO NOT MODIFY THE PLUG DO NOT OVERLOAD THE CIRCUIT BY PLUGGING TOO MANY DEVICES IN TO ONE CIRCUIT Your DVR is now read...

Page 21: ...s You will use these to initially set up your DVR and for daily operations 3 1 1 Power LED The Power LED is lit when the DVR is on 3 1 2 Network LED The Network LED is lit when the unit is connected with RAS Remote Administration System either via Ethernet or modem 3 1 3 Backup LED The Backup LED is lit when data is being backed up using the USB port 3 1 4 Camera Buttons 1 to 16 Pressing the indiv...

Page 22: ...t live screen Used for near Focus in the PTZ mode 3 1 9 Alarm Button The Alarm button has two functions First it will reset the DVR s outputs including the internal buzzer during an alarm Second it will display the event log when you are in the live monitoring mode unless there is an active alarm This operation can be user password protected Used for far Focus in PTZ mode 3 1 10 Spot Button Pressi...

Page 23: ... the video The screen displays when the DVR is playing back video The screen displays when in the Pause mode Entering Playback mode from Live Monitoring mode can be user password protected 3 1 16 Next Button The Next button only functions when playback video has been paused Pressing the Next button plays video forward image by image 3 1 17 FF Fast Forward Button Pressing the FF button plays video ...

Page 24: ...he first time you will want to establish the initial settings This includes items such as time and date display language camera audio remote control record mode network and password Your DVR can be set up using various screens and dialog boxes Press the Menu button to enter the setup screens The Admin Password screen appears Fig 18 Admin Password screen Enter the password by pressing the appropria...

Page 25: ...dio Recording and select either On or Off NOTE It is the user s responsibility to determine if local laws and regulations permit recording audio z Highlight the box beside Sequence Dwell Time and select from 3 to 60 seconds for the camera sequence dwell time z Selecting System Information enters that screen z Selecting Storage enters a screen where you can check the storage status z Selecting Came...

Page 26: ...r settings to the factory default settings 3 5 1 System Information Highlight System Information and press the button The System Information screen appears Fig 21 System Information screen In the System Information screen you can name the site location assign a unit ID number select the language for the screen display and upgrade the software Highlight Change and press the button The System Inform...

Page 27: ...d with other DVRs You cannot use the same number for two or more DVRs that are within the same network z Highlight the box beside Language and press button A dropdown menu displays the available languages Highlight the desired language and press the button Fig 23 Language dropdown menu z Highlight the box beside Site Description and press the button A virtual keyboard displays Fig 24 Virtual keybo...

Page 28: ... the System Information Change screen z To upgrade the software connect the USB device containing the upgrade package file to the DVR Highlight Upgrade and press the button The System Upgrade screen appears The screen displays the upgrade package file name CAUTION System upgrade via USB port might NOT be completed properly if the USB device has been connected to the other USB port Please remove an...

Page 29: ...row buttons to move between hour minutes and seconds Once you have the correct time press the button NOTE The clock will not start running until you have restarted the unit so you may wish to set the time last z Highlight the box beside Time Zone and press the button Select the time zone you are in from the list and press the button z Highlight the box beside Daylight Saving Time and press the but...

Page 30: ...Off z Highlight the box beside SNTP Server and press the button Change the numbers by highlighting them and using the Up and Down arrow buttons to increase or decrease the number value z Highlight the box beside Interval and press the button Set the time interval for synchronization from 1 to 300 minutes z The box beside System Clock displays the DVR s time setting z The box beside Server Clock di...

Page 31: ...button Pressing the button toggles between On and Off When it is On the DVR you are setting up will run as a time server z You can save your changes by highlighting OK and pressing the button Selecting Cancel exits the screen without saving the changes z Highlight the box beside Date Format and press the button A list of date formats appears Highlight the format you wish to use and press the butto...

Page 32: ...or if there is an alarm during the designated time z Highlight the box under the Interval heading and press the button A slide bar appears allowing you to set the check interval from 1 Hour to 30 Days by using the Left and Right arrow buttons z The Status field displays the fault conditions When it is Good there was recording or an alarm occurred during the designated time When it is Bad there was...

Page 33: ...al Bad Data cannot be written to or read from the storage device S M A R T Not work Storage conditions are normal however the S M A R T monitoring is not working or supported S M A R T Alert S M A R T monitoring has detected a fault condition High Temperature S M A R T monitoring has detected that the temperature of storage device exceeded the preset temperature threshold Not installed The storage...

Page 34: ... Self Monitoring Analysis and Reporting Technology program Highlight the box beside Use Press the button to toggle between On and Off z The Last check filed displays the date and time information of the last storage check z Highlight the box beside Period and select from Daily Weekly or Monthly for the check interval NOTE When selecting Weekly or Monthly the Day of Week or Day of Month field will ...

Page 35: ... most recent to the oldest You can scroll through the list a page at a time by selecting the Up and Down arrow buttons and pressing the button You can go directly to an event number by highlighting the event number box left of the UP arrow pressing the button using the arrow buttons to change the number and pressing the button 3 5 6 System Shutdown Highlight System Shutdown in the Main menu and pr...

Page 36: ...ays the camera inputs in groups of four 1 to 4 5 to 8 9 to 12 and 13 to 16 You can turn the camera number on or off and also hide the video from a camera by highlighting the camera Setup heading and pressing the button Select from On Off Covert 1 or Covert 2 NOTE When set to Covert 1 the DVR displays the camera title and status icons on the covert video When set to Covert 2 the DVR displays only t...

Page 37: ... button Change the number by highlighting it and using the Up and Down arrow buttons to increase and decrease the number The PTZ ID number can be set from 0 to 256 3 6 2 Alarm In Setup Screen Highlight Alarm In in the Main menu and press the button The Alarm In setup screen appears Fig 36 Alarm In setup screen The alarm terminal strip on the back of the DVR has inputs associated with each alarm Yo...

Page 38: ...nder the Min Size heading and adjust the number The smaller the number fewer detection blocks must be activated and therefore more sensitive Turning the View setting On will allow you to observe how the DVR is reacting to motion When in the motion viewing mode the detection zone of video will be displayed in green Any detected motion within the zone will be displayed in red You can define the area...

Page 39: ...creen The menu on the setup screen has the following functions Fig 39 Motion Detection Zone screen z Close this menu Closes the menu so that you can see the entire screen z Select Current Blocks Activates highlighted blocks to detect motion z Clear Current Blocks Deactivates highlighted blocks so that they will not detect motion z Select All Blocks Activates all blocks to detect motion z Clear All...

Page 40: ... individual blocks of time entire days of the week entire blocks of time or the entire schedule Select a specific block of time by highlighting it Select an entire day by highlighting the day of the week or Holiday on the left of the screen Select an entire block of time by highlighting the time at the top of the screen Select the entire screen by highlighting the empty box in the upper left corne...

Page 41: ...etween On and Off When it is On the DVR will NOT play live or recorded audio Highlight the box beside Audio In Pressing the button toggles between Mic In and Line In Mic In is for an un amplified source while Line In is for an amplified source You can save your changes by highlighting OK and pressing the button Selecting Cancel exits the screen without saving the changes NOTE If you set up the rec...

Page 42: ... possible to select either Remote Control or PTZ Control in the Usage field It is possible to select either External Modem or Remote Control in the RS232 Usage field and select either Remote Control or PTZ Control in the RS485 Usage field NOTE Both the RS232 and RS485 ports cannot be configured to communicate with remote controls at the same time NOTE If networking is configured by the external mo...

Page 43: ...igh When set to Standard the DVR records video with the resolution similar to VHS quality When set to High the DVR records video with the resolution similar to DVD quality NOTE When the Record Resolution is set to High the recording and playback speed will be decreased in half NOTE The Record Resolution will be fixed to Standard when the DVR is in the Quick Setup mode z Highlight the box beside En...

Page 44: ...Auto Deletion and press the button to select the length of time recorded data will be kept from 1 to 99 days z You can save your changes by highlighting OK and pressing the button Selecting Cancel exits the screen without saving the changes 3 7 2 Time Lapse Record Mode Setup Screen Fig 45 Time Lapse Record Setup screen z Highlight the box under Speed and press the button A drop down list of record...

Page 45: ...s such as motion and image complexity 3 7 3 Time Lapse Recording Schedule Fig 46 Time Lapse Recording Schedule screen You can program the DVR to record only during certain times based on time day of the week and holidays The smallest time segment you can use is 30 minutes A blue rectangle indicates the DVR is set to record during those 30 minutes When there is no rectangle the DVR will not record ...

Page 46: ... event occurs The Pre Event Record screen allows you to define how to handle pre event recording You can turn individual cameras On or Off for pre event recording The image speed can be set from 0 1 to 50 ips 60 ips NTSC and image quality can be selectable from High Standard and Low You can set the amount of time to record prior to the event by adjusting the Dwell You can set the Dwell from 1 to 3...

Page 47: ...In Event Action Record setup screen z Highlight the Sched box and press the button A schedule screen appears Set the schedule as described earlier z Highlight the Camera box and press the button A camera selection screen appears Select the camera number you would like to associate with the sensor NOTE You can associate multiple cameras with a sensor z Highlight the Speed box and select number of i...

Page 48: ...pears Set the schedule as described earlier z Highlight the Alarm Out box and select either Beep or the alarm output terminal that you want to associate with the sensor z Highlight the Dwell box and set the length of time you want the output activated NOTE When setting the Dwell to 0 sec the alarm output will be activated throughout the sensor activation period and inactive while the sensor is ina...

Page 49: ...e screen appears Set the schedule as described earlier z Highlight the Notify box and press the button This toggles between On and Off When it is On the DVR notifies the remote site when certain alarm inputs are activated based on a defined schedule 3 8 4 Motion Detector Event Action Record Setup Screen The DVR can be set to react to motion detector differently Each camera can be assigned a schedu...

Page 50: ...to record for the associated motion event 3 8 5 Motion Detector Event Action Alarm Out Setup Screen The DVR can be set to react to motion events differently by activating an internal buzzer or external alarms Fig 52 Motion Detector Event Action Alarm Out setup screen z Highlight the Sched box and press the button A schedule screen appears Set the schedule as described earlier z Highlight the Alarm...

Page 51: ...utton A schedule screen appears Set the schedule as described earlier z Highlight the Notify box and press the button This toggles between On and Off When it is On the DVR notifies the remote site when certain motion events occur based on a defined schedule 3 8 7 Video Loss Event Action Record Setup Screen The DVR can be set to react to video loss from a camera differently Each camera can be assig...

Page 52: ...quality you want to record from the drop down menu z Highlight the Dwell box and set the length of time you would like to record for the associated video loss 3 8 8 Video Loss Event Action Alarm Out Setup Screen The DVR can be set to react to video loss differently by activating an internal buzzer or external alarms Fig 55 Video Loss Event Action Alarm Out setup screen z Highlight the Sched box an...

Page 53: ...back Center Modem Setup screen Fig 56 Video Loss Event Action Notify setup screen z Highlight the Sched box and press the button A schedule screen appears Set the schedule as described earlier z Highlight the Notify box and press the button This toggles between On and Off When it is On the DVR notifies the remote site when it loses video input from a camera based on a defined schedule 53 Siemens B...

Page 54: ...e the date display On and Off z Highlight the box beside Time and press the button to toggle the time display On and Off z Highlight the box beside Title and press the button to toggle the camera title display On and Off z Highlight the box beside Status and press the button to toggle status display On and Off z Highlight the box beside Left Right Margin and press the button to adjust the left and...

Page 55: ...ty of formats and set the DVR to sequence through the different screen layouts pages so that all the cameras will be displayed You can also set up the DVR to display one camera or a group of cameras all the time while cycling through the remaining cameras in a cameo window This can be done with one camera displayed full screen while displaying the cameo window as a PIP picture in picture or displa...

Page 56: ... to 60 seconds z Highlight the box beside Event Monitoring and press the button to toggle between On and Off When it is On the video of the lowest camera number among cameras associated with the event detected sensor will be displayed in full screen on the spot monitor during the preset dwell time z Highlight the box beside Event Monitoring Dwell Time and press the button You can adjust the event ...

Page 57: ...e case sensitive The factory default password for both Administrator and User is 12345678 CAUTION Write the password down and keep it in a safe place Once the password has been reset the default will no longer work If the password is forgotten the unit must be reset using the Factory Reset Button and all data settings will be lost z Highlight the box beside Transfer Control Press the button to tog...

Page 58: ...ton Select the image quality from Very High High Standard and Low 3 10 1 LAN Setup Screen Fig 61 LAN Setup screen Highlight the box beside Use dynamic IP Configuration DHCP and press the button to toggle between On and Off NOTE When set to On the IP Address Gateway and Subnet Mask will be set automatically so you cannot change the LAN settings NOTE When you use the DHCP the IP address of the DVR m...

Page 59: ...efer to the RAS manual for details You can save your changes and return to the Network Setup screen by highlighting OK and pressing the button Selecting Cancel exits the screen without saving the changes 3 10 2 Modem Setup Fig 62 RS232 RS485 setup screen NOTE Modem setup is done through the RS232 RS485 screen in the Devices menu which can be accessed from the Main Menu NOTE If the RS232 port is in...

Page 60: ...a computer running RAS Remote Administration System or send an e mail on a LAN when an event occurs z Highlight the box beside IP Address and enter the IP address of the computer you want contacted during an event z Highlight the box beside Retry and enter the number of times you would like the DVR to try contacting the computer You can select from 1 to 10 retries z Highlight the box beside E mail...

Page 61: ... enter the number of times you would like the DVR to try contacting the computer You can select from 1 to 10 retries NOTE When any event occurs the DVR will call a remote site to give notice of an event The DVR will hold the phone line for 30 seconds after connecting a remote site to wait for other events that might occur If another event occurs while the DVR is holding the line the DVR will hold ...

Page 62: ...o enter the current password so that you can turn it Off If the password is set to Off you will be asked to enter the new password and to confirm it before it will be turned on The Administrator password cannot be turned On and Off You can change the Administrator password by first entering the current password entering a new password and finally confirming the new password To change the password ...

Page 63: ... Lock password is 4231 You can save your changes by highlighting OK and pressing button Selecting Cancel exits the screen without saving the changes 3 12 Config Screen The Config menu is used to perform functions such as switching between Quick Setup and System Setup archiving video copying video clips loading default setup and clearing all data Fig 66 Config screen 63 Siemens Building Technologie...

Page 64: ...te the DVR continues archiving when the device drive is full by overwriting the oldest video When set to Stop the DVR stops archiving when the device drive is full Highlight the box beside Auto Archive and press the button This toggles between On and Off When it is On the DVR will archive video automatically from the time set on the Archive From field Highlight the box beside Archive From and pres...

Page 65: ...d dates Once you set the archive start and stop times and dates highlight the Archive Now button and press the button You can end the archiving process at any time by highlighting the Stop button and pressing the button NOTE The Stop button will display only during archiving NOTE If you have a large quantity of recorded video to archive either stop recording or reset the recording speed The oldest...

Page 66: ... fewer external SCSI hard disk drives connected to the DVR You can define how much video to copy changing the start and end times and dates You can also select which camera you wish to copy Highlight the File Name box and press the button A virtual keyboard appears Enter a file name for the video you are copying and select Close The DVR will automatically add the camera number for example 01 and e...

Page 67: ...to use for clip copy the DVR will display the drive capacity the clip size and ask if you want to continue NOTE Do not copy clips larger than 2GB You can use other functions on the DVR while video is being copied To do this highlight the Close button and press the button You can return to the Clip Copy screen at any time to check the progress NOTE You can not end the clip copy process during CD bu...

Page 68: ...sk drive has been corrupted this error message cannot be dismissed Even after restarting the DVR it may automatically restart while preparing clip copy You must recover the file system using the recovery program or you must reformat the hard disk drive 3 12 3 Load Default Setup Highlighting and selecting Load Default Setup will bring up screen asking you if you really want to load default settings...

Page 69: ...ion process it will begin showing live video on the attached monitor and playing live audio through the attached speaker The default mode is to display all cameras at once Pressing any camera button will cause that camera to display full screen It displays live video and plays live audio until the user enters another mode Pressing the Display button cycles the DVR through the different display for...

Page 70: ...tive cameo to the camera you want to control Then exit from the Active Cameo mode by pressing the button again to control the selected camera NOTE The active cameo mode can be set or released in the playback mode while playback video is paused 4 2 2 PIP Mode You can display a Picture in Picture by pressing the Display button You can change the location of the PIP by pressing the Up and Down arrow ...

Page 71: ...Although you will be able to record without changing the unit from its original factory settings you will want to take advantages of the DVR s many tools See Chapter 3 Configuration for detailed descriptions of the recording mode options NOTE The DVR is NOT recording if only the red LED above the REC button is lit When the DVR is set for Time lapse or Event recording the red LED above the REC butt...

Page 72: ...he display modes are full 4 x 4 3 x 3 and 2 x 2 not all formats are available for the 9 and 4 channel DVRs NOTE You cannot change the display format while playing back video Pause the video first then change the format 4 5 3 RW Rewind Button Pressing the RW button plays video backward at high speed Pressing the button again toggles the playback speed from and The screen displays and respectively E...

Page 73: ... Last Displays the last recorded image z Date Time Search Searches by date and time see below for more details z Calendar Search Searches using a calendar see below for more details z Event Search Selects video from the event log see below for more details NOTE The searching speed might decrease when all camera channels are in the pre alarm recording mode 4 6 1 Change Data Source Fig 76 Change Dat...

Page 74: ...r highlight the OK button and press the button The selected date and time will display If no video was recorded at the selected time a blank screen will display The Play Pause RW FF PREV and Next buttons can now be used to review the surrounding video 4 6 3 Calendar Search Fig 78 Calendar Search screen Days with recorded video display on the calendar with white numbers You can highlight the days w...

Page 75: ...og of each time the Alarm Input port is activated The Event Log screen displays this list Use the arrow buttons to highlight the event for which you would like to see video NOTE Event Search does not work when the data source is set to Search On Archive Pressing the button will extract the event video and display the first image of the event Pressing the Play Pause button will start playing the ev...

Page 76: ...nd stop times and dates When you select the Search by Camera select the target cameras and event options When you select the Search by Event select event options for each device Once you set your desired search conditions highlight Search and press the button to display the search results in the Event Log screen Selecting Cancel exits the screen without saving the changes 76 Siemens Building Techn...

Page 77: ...77 Siemens Building Technologies SISTORE AX9 AX16_EN doc Fire Security Products 09 2004 ...

Page 78: ... the file system is NOT FAT32 format format the USB IDE hard disk drive using the FAT32 format 5 If the USB IDE hard disk drive is not partitioned go to Administrative Tools in Control Panel and launch Computer Management Open Disk Management in Storage and right click an unallocated region of the USB IDE hard disk drive Then click Create Partition 6 In the Create Partition wizard click Next then ...

Page 79: ...cking Start then RUN Type fdisk and click OK 6 When the MS DOS command prompt appears type Y and hit the enter key 7 In the FDISK Option menu choose 5 Change current fixed disk drive 8 Choose the appropriate letter corresponding to the USB IDE hard disk drive 9 In the FDISK Option menu choose 1 Create DOS partition or Logical DOS Drive 10 In the Create DOS Partition or Logical DOS Drive menu choos...

Page 80: ...cking the right mouse button on the images switches the screen size between 320 x 240 and 640 x 480 Clicking the Quit button exits the Player program Click the Print button to print the current image on the printer connected to your computer Click the Save button to save the current image in a bitmap file format to the local hard disk drive or floppy disk The Backup File Information window display...

Page 81: ...ast forward go to the first image go to the previous image go to the next image and go to the last image buttons The Brightness Control Slide Bar adjusts the brightness of the clip images by clicking the mouse and dragging along the slider bar Minute brightness change can be made by using the arrow buttons located at each end of the bar The Brightness Revert Button reloads to the original image Cl...

Page 82: ...defined during configuration REC LED indicates the DVR is ready to record DVR has stopped recording If hard disk drive is full you will either need to delete video or set the DVR to the Overwrite Mode DVR displays an error message stating that the last recorded image date and time is later than the current date and time setting of the DVR The DVR will automatically reset the time and date of the u...

Page 83: ... 3 Alarm Output 1 16 Alarm Output 4 4 Alarm Reset 17 Ground 5 Alarm Input 16 18 Alarm Input 15 6 Alarm Input 14 19 Alarm Input 13 7 Alarm Input 12 20 Alarm Input 11 8 Alarm Input 10 21 Alarm Input 9 9 Ground 22 Alarm Input 8 10 Alarm Input 7 23 Alarm Input 6 11 Alarm Input 5 24 Alarm Input 4 12 Alarm Input 3 25 Alarm Input 2 13 Alarm Input 1 83 Siemens Building Technologies SISTORE AX9 AX16_EN doc...

Page 84: ...site at the same time via RAS program External modem and remote controller cannot be used at the same time z Default interface parameter for external analog modem z Baud Rate 57600 Data Bit 8 Stop Bit 1 Parity NONE z Default interface parameter for external ISDN modem z Baud Rate 115200 Data Bit 8 Stop Bit 1 Parity NONE z Callback to RAS and callback to the pager cannot be used at the same time z ...

Page 85: ...ra setting PTZ Device Siemens SCU ID 1 Configuration of the Roline RS232 RS485 Converter z T RTS Rx ON z DTE or DCE must not be identical with the other converter Configuration of the RS232 Current Loop Converter z 20 mA z Rx ACT Active z Tx ACT Active z DCE or DTE must not be identical with the other converter If the two converters are connected using a cross over cable either DCE or DTE must be ...

Page 86: ...ard 5 4KB Low 3 6KB 60 ips NTSC 1 5 3 8 8 9 13 4 50 ips PAL 1 8 4 6 10 7 16 1 30 ips NTSC 3 0 7 7 17 9 26 8 25 ips PAL 3 6 9 2 21 4 32 2 20 ips 4 5 11 5 26 8 40 2 15 ips 6 0 15 3 35 7 53 6 10 ips 8 9 23 0 53 6 80 4 5 ips 17 9 45 9 107 2 160 8 2 5 ips 35 7 91 9 214 3 321 5 1 ips 89 3 229 6 535 8 803 8 0 5 ips 178 6 459 3 1 071 7 1 607 5 0 25 ips 357 2 918 6 2 143 3 3 215 0 0 1 ips 893 1 2 296 4 5 3...

Page 87: ...Appendix G Screens Map 11 Appendix G Screens Map 87 Siemens Building Technologies SISTORE AX9 AX16_EN doc Fire Security Products 09 2004 ...

Page 88: ...Alarm I O Board Alarm Output 4 dry contact open collector 5 mA 12 V 30 mA 5 V Alarm Reset Input 1 dry contact 4 3 V threshold using supplied Alarm I O Board Network Connectivity 10 100 Mbps Ethernet RS232 for external modem Audio Input One line in or mic programmable Audio Output One line CONNECTORS Video Input Composite 9 or 16 BNC Video Loop Composite 9 or 16 BNC Monitor Output Composite 1 BNC S...

Page 89: ...21 3 x 12 1 x 20 1 540 x 175 x 510 mm Operating Temperature 41 to 104 F 5 to 40 C Operating Humidity 0 to 90 Power Supply 100 to 240 V AC 1 2 A 60 50 Hz Auto ranging adapter included Input Voltage Current 12 V DC 5 8 A Power Consumption 70 Watts Max APPROVALS FCC FCC PART 15 Subpart B Class A CE EMI EN55022 1998 Class A Safety EN60950 Immunity EN50130 4 1998 Alarm Standard Specifications are subje...

Page 90: ...the RS485 17 Connecting to the UltraWide SCSI Port 18 Connecting to the USB Port 19 Connector Pin Outs 85 D Date Time Search 75 Date Time Setup 29 Display Button 22 73 Duplex LED 21 E Enter Button 24 Event Action Setup 48 Event Search 77 F Factory Reset 19 Features 11 FF Fast Forward Button 23 74 Freeze Button 22 Front Panel Controls 21 G GND Ground 16 I Initial Unit Setup 24 Installation 13 L LAN...

Page 91: ...y Setup Screen 56 Setting Unit for PAL or NTSC 13 Stop Button 23 74 Storage Check Screen 33 System Check Screen 32 System Information 26 System Log Screen 36 System Shutdown 36 T Time Lapse Record Mode Setup Screen 45 Time Lapse Recording Schedule 46 Troubleshooting 84 Turning on the Power 24 70 U Up Down Left Right Arrow Buttons 24 USB connector 19 USB Hard Disk Drive 80 V Video Loss Event Action...

Page 92: ... com FSP 2004 Copyright by Siemens Building Technologies AG Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper Document no A24205 A336 B545 Edition 09 2004 ...

Reviews: