background image

© Siemens AG 2017. All rights reserved 

C79000-G8976-C477-01, 12/2017 

1

 

 

SIMATIC Ident 

 

RFID systems 

SIMATIC RF645T 

 

Compact Operating Instructions 

 

Legal information 
Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The 

notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage 

have no safety alert symbol. These notices shown below are graded according to the degree of danger. 

 

DANGER 

indicates that death or severe personal injury will result if proper precautions are not taken. 

 

WARNING 

indicates that death or severe personal injury may result if proper precautions are not taken. 

 

CAUTION 

indicates that minor personal injury can result if proper precautions are not taken. 

 

NOTICE 
indicates that property damage can result if proper precautions are not taken. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of 

injury to persons with a safety alert symbol may also include a warning relating to property damage. 

Qualified Personnel 

The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with 

the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their 

training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. 

Proper use of Siemens products 

Note the following: 

WARNING 

Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products 

and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, 

installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any 

problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. 

Siemens Distributor

Summary of Contents for SIMATIC RF645T

Page 1: ...ce representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and s...

Page 2: ...PC 56 bytes 448 bits User memory 256 bytes 2048 bits Reading range 1 Up to 6 0 m Installation For mounting directly on metal surfaces 1 Depending on the environment the employed reader the antennas and the configured power 2 Ordering data Table 2 1 Ordering data Article number SIMATIC RF645T 6GT2810 2HC05 Mounting cover for SIMATIC RF645T 6GT2898 5AA00 Retaining bracket for SIMATIC RF645T 6GT2898 ...

Page 3: ...ne Perchloroethylene Acetone Alcohols Hot water hydrolysis resistance UV light and weathering Explanation of the rating Resistant Conditionally resistant Not resistant 4 Read write ranges Table 4 1 Read range between RF600 antennas and SIMATIC RF645T 1 Antenna type Read ranges RF620A 1 5 m RF640A 5 0 m RF642A 6 0 m RF650A 4 0 m RF660A 5 0 m RF680A 5 0 m 1 Ranges with max reader performance e g RF6...

Page 4: ...type NXP UCode 7xm 2k Memory configuration EPC 56 bytes 448 bits User memory 256 bytes 2048 bits TID 12 bytes 96 bits Number of write cycles 40 C 100 000 Number of read cycles 40 C 1014 Data retention time 40 C 20 years Electrical data Read range on the metallic support 6 m 1 Protocol EPCglobal Class 1 Gen 2 ISO 18000 63 Transmission speed 320 kbps Polarization Linear long side polarization axis M...

Page 5: ...istance to mechanical stress Not permitted Design dimensions and weight Dimensions L x W x H 52 0 5 36 0 5 12 5 mm Weight Approx 25 g Type of mounting Glued Mounting cover M4 Retaining bracket M5 1 Depending on the environment 2 The values for shock and vibration are maximum values and must not be applied continuously 6 Certificates and approvals Table 6 1 Certificates and approvals Labeling Descr...

Page 6: ...C477 01 12 2017 7 Dimension drawing All dimensions in mm SIMATIC RF645T Figure 7 1 Dimension drawing of SIMATIC RF645T Retaining bracket for SIMATIC RF645T Figure 7 2 Dimension drawing mounting cover 6GT2898 5AA00 for SIMATIC RF645T ...

Page 7: ...for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be precluded entirely we cannot guarantee full consistency However the information in this publication is reviewed regularly and any necessary corrections are included in subsequen...

Reviews: