Summary of Contents for RUGGEDCOM RX1512

Page 1: ...Edition 07 2019 Installation Manual SIMATIC NET Industrial Ethernet Switches RUGGEDCOM RX1512 https www siemens com ...

Page 2: ... Industrial Ethernet Switches RUGGEDCOM RX1512 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 07 2019 C79000 G8976 1057 ...

Page 3: ... personnel are those who based on their training and experience are capable of identify ing risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufactur...

Page 4: ...ing Recommendations 4 2 Installing the Device 5 2 1 General Procedure 6 2 2 Unpacking the Device 6 2 3 Mounting the Device 6 2 3 1 Mounting the Device on a DIN Rail 7 2 3 2 Mounting the Device to a Panel 8 2 4 Connecting the Failsafe Alarm Relay 8 2 5 Connecting Power 9 2 5 1 Connecting Low DC Power 10 2 5 2 Testing Dielectric Strength 12 3 Device Management 15 3 1 Connecting to the Device 15 3 2 ...

Page 5: ...Mechanical Specifications 34 5 5 Dimension Drawings 34 6 Certification 37 6 1 Approvals 37 6 1 1 TÜV SÜD 37 6 1 2 European Union EU 37 6 1 3 FCC 39 6 1 4 FDA CDRH 39 6 1 5 ISED 39 6 1 6 RoHS 39 6 1 7 Other Approvals 40 6 2 EMC and Environmental Type Tests 40 iv RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 6: ...og https support indus try siemens com cs ww en view 109747072 Accessing Documentation The latest user documentation for RUGGEDCOM RX1512 is available online at https www siemens com To request or inquire about a user document contact Siemens Customer Support Disclaimer of Liability Siemens has verified the contents of this document against the hardware and or soft ware described However deviation...

Page 7: ...omer s exclusive remedy for defective or nonconforming goods or services whether claims of the Customer are based in contract including fundamental breach in tort including negligence and strict liability or otherwise For warranty details visit https www siemens com or contact a Siemens customer service representative Training Siemens offers a wide range of educational services ranging from in hou...

Page 8: ...ult aspx Mobile App Install the Industry Online Support app by Siemens AG on any Android Apple iOS or Windows mobile device and be able to Access Siemens extensive library of support documentation includ ing FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fell...

Page 9: ...Preface Contacting Siemens viii RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 10: ...ost any location 1 1 Feature Highlights Reliability in Harsh Environments Immunity to EMI and high voltage electrical transients 40 to 85 C 40 to 185 F operating temperature no fans Failsafe output relay for critical failure or error alarming Universal Power Supply Options Fully integrated power supply no ex ternal adapter Input voltage range 11 72 VDC CSA UL 60950 1 safety approved to 85 C 185 F ...

Page 11: ...software or install files such as configuration files and feature key files For more information refer to the RUGGEDCOM RUGGEDCOM RX1512 User Guide for the RUGGEDCOM RX1512 Lamp Test Alarm Cut Off LT ACO Button This button performs two functions Press and hold this button to test all indicator LEDs Press and release this button to acknowledge an active alarm Power Status LEDs Indicates the status ...

Page 12: ... the device to a panel Braided or equivalent ground wire For grounding the device to safety Earth 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment Decommissioning This device may include sensitive proprietary data Before taking the device out of service e...

Page 13: ... the Telecommunications Industry Association TIA TIA EIA 568 A wiring standard that characterizes minimum cabling performance specifications required for proper Gigabit Ethernet operation For reliable error free data communication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summarizes the relevant cabling standards Cabling Category 1...

Page 14: ...gineering_Technology Documents bul letins oet65 oet65 pdf The emitted radiation should be as little as possible To achieve minimum RF exposure install the device when it is configured not to trans mit and set it to operational mode remotely rather than having a technician enable transmission on site For maintenance of the base station or other operations which require RF exposure the exposure shou...

Page 15: ...tallation or regulatory requirements related to the modules installed in the device In the case of cellular modem line modules this includes antenna installation and reg ulatory requirements 3 Mount the device 4 Connect the failsafe alarm relay 5 Connect power to the device and ground the device to safety Earth 6 Connect the device to the network 7 Configure the device 2 2 Unpacking the Device Whe...

Page 16: ...with either DIN rail or panel hardware installed refer to Dimension Drawings Page 34 2 3 1 Mounting the Device on a DIN Rail For DIN rail installations the RUGGEDCOM RX1512 can be equipped with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be slid onto a standard 35 mm 1 4 in DIN rail To mount the device to a DIN rail do the following 1 Align th...

Page 17: ...ounting 2 Prepare the mounting holes 3 Align the device with the mounting holes and secure it to the panel 2 4 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no ac tive alarms If the device is not powered or if an active alarm is configured the relay opens the ...

Page 18: ...rvicing the power module terminals Make sure the power source is off before servicing the power terminal NOTICE Use minimum 16 gage copper wiring when connecting terminal blocks The maximum wire length between the terminal block and power source must not exceed 6 m 20 ft for 24 V power supplies or 18 m 60 ft for 48 V power supplies For 125 230 VAC rated equipment an appropriately rated AC circuit ...

Page 19: ...rd risk of damage to equipment In normal operation the jumper between the chassis ground and surge ground ter minals must be installed for proper operation Damage to the device may occur oth erwise Removing the jumper may also void the warranty Note The RUGGEDCOM RX1512 works with both positive VDC power supplies and negative VDC power supplies Note For information about how to safely test the die...

Page 20: ...egative Terminal 5 Jumper 6 Chassis Ground Connection Figure 2 4 DC Terminal Block Wiring for Positive VDC Power Supplies 2 1 3 4 5 6 1 Surge Ground Terminal 2 Positive Terminal 3 Chassis Ground Terminal 4 Negative Terminal 5 Jumper 6 Chassis Ground Connection Figure 2 5 DC Terminal Block Wiring for Negative VDC Power Supplies RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 11 ...

Page 21: ... chassis ground connection on the device Make sure the lug is tightened to 1 1 N m 9 5 lbf in 3 2 1 4 1 10 Ring Lug 2 10 32 Screw 3 Connection from External Power Source 4 Chassis Ground Connection Figure 2 6 Chassis Ground Connection 6 Install the safety cover over the terminal block This is mandatory for 48 VDC and 48 VDC power supplies 2 5 2 Testing Dielectric Strength Before performing any die...

Page 22: ... damage to transient sup pression circuitry during testing 2 1 3 4 5 1 Surge Ground Terminal 2 Positive Terminal 3 Chassis Ground Terminal 4 Negative Terminal 5 Jumper 6 Chassis Ground Connection Figure 2 7 Jumper 2 Connect one terminal from the HIPOT tester to the positive terminal and the negative terminal Connect the second terminal of the HIPOT tester to chassis ground terminal Do not connect ...

Page 23: ...Installing the Device 2 5 2 Testing Dielectric Strength 14 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 24: ... console and Web interfaces NOTICE The serial console and management MGMT ports are intended to be used only as temporary connections during initial configuration or troubleshooting Connection to the console port is made using an RJ 45 to DB9 console cable The fol lowing is the pin out for the console port 1 8 Figure 3 1 RJ 45 Console Port Pin Configuration Pin RJ 45 Male DB9 Female Name Descripti...

Page 25: ...e available Ethernet ports on the device to a management switch and access the RUGGEDCOM RX1512 console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RX1512 is https 192 168 0 2 For more information about available ports refer to Modules Page 21 Note Single mode fiber ports only support Ultra Physical Contact UPC cable connectors 3 2 Configuring th...

Page 26: ...ror data corruption or hardware fault CAUTION Configuration hazard risk of data corruption loss The following will void the war ranty and potentially result in configuration data corruption loss Using a CF card not approved by Siemens for use with this device Removing the CF card in any scenario other than those described in this section Inserting the CF card To insert the CF card into the device ...

Page 27: ...eated 2 3 1 1 CompactFlash Card 2 Access Panel Figure 3 3 Inserting the CF Card 4 Secure the CF card access panel to the chassis Removing the CF card To remove the CF card from the device do the following 1 Make sure the device is powered down 18 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 28: ...l 2 3 1 1 Ejector Button 2 CompactFlash Card 3 Access Panel Figure 3 4 Removing the CF Card 3 Press the ejector button to the left of the CF card and then pull the card out 4 Secure the CF card access panel to the chassis RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 19 ...

Page 29: ...Device Management 3 3 Accessing the CompactFlash Card 20 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 30: ...tly from within the RUGGEDCOM RX1512 is also available Modules can be installed in any one of the available slots in the device chassis Use the RUGGEDCOM RUGGEDCOM RX1512 software to determine which ports are equipped on the device For more information refer to the RUGGEDCOM RUGGED COM RX1512 User Guide for the device Note Only one T1 E1 WAN module or up to two DDS modules are supported 2 1 1 Slot...

Page 31: ...2 Speed 1000 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled By pass Distance 100 m 328 ft Article Numbers 6GK6015 0AL20 0PE0 Standard 6GK6015 0AL20 0PE1 Conformal Coated RUGGEDCOM RX1500PN LM X CG04 Specifications Ports 2 Speed 1000 Mbps Interface TX Port Type M12 8 pin X Coded Distance 100 m 328 ft Article Numbers 6GK6015 0AL20 0PH0 Standard 6GK6015 0AL20 0PH1 Conformal Coated RUGGEDCOM...

Page 32: ... 4TX04B Specifications Ports 4 Speed 100 Mbps Interface TX Port Type M12 4 Pin A Coded Controlled By pass Distance 100 m 328 ft Article Numbers 6GK6015 0AL20 0PG0 Standard 6GK6015 0AL20 0PG1 Conformal Coated RUGGEDCOM RX1500PN LM 6TX01 Specifications Ports 6 Speed 100 Mbps Interface TX Port Type RJ45 Distance 100 m 328 ft Article Numbers 6GK6015 0AL20 0NB0 Standard 6GK6015 0AL20 0NB1 Conformal Coa...

Page 33: ...1 Conformal Coated RUGGEDCOM RX1500PN LM FX50 Specifications SFP Sockets 4 Speed 100 Mbps Article Numbers 6GK6015 0AL20 0JC0 Standard 6GK6015 0AL20 0JC1 Conformal Coated RUGGEDCOM RX1500PN LM 6FX50 Specifications SFP Sockets 6 Speed 100 Mbps Article Numbers 6GK6015 0AL20 0JD0 Standard 6GK6015 0AL20 0JD1 Conformal Coated WAN Modules RUGGEDCOM RX1500PN LM S01 Specifications Standard RS232 RS422 RS48...

Page 34: ...eed 56 kbps Mas ter Slave or 64 kbps Slave Ports 1 Port Type RJ48S Article Numbers Stan dard 6GK6015 0AL20 0LB0 Standard 6GK6015 0AL20 0LB1 Conformal Coated Cellular Modem Modules RUGGEDCOM RX1500PN LM W11 Specifications Services GSM EDGE HS PA Region North America AT T Port Type 50 Ω SMA Antennas 1 x GSM EDGE HSPA 1 x Re ceive Diversity Se condary SIM Dual Mini SIM 2FF Article Numbers Stan dard 6...

Page 35: ...E0 Standard 6GK6015 0AL20 0WE1 Conformal Coated RUGGEDCOM RX1500PN LM W32 Specifications Services EVDO Rev A Region North America Verizon Port Type 50 Ω SMA Antennas 1 x GSM EDGE HSPA 1 x EVDO Rev A 2 x Receive Diver sity Secondary SIM Dual Mini SIM 2FF Article Numbers Stan dard 6GK6015 0AL20 0WF0 Standard 6GK6015 0AL20 0WF1 Conformal Coated RUGGEDCOM RX1500PN LM W41 Specifications Services 4G LTE...

Page 36: ...andard 6GK6015 0AL20 0WJ1 Conformal Coated RUGGEDCOM RX1500PN LM W81 Specifications Services 4G LTE HSPA EDGE GPRS GSM UMTS GNSS Region Asia Pacific Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Article Numbers Stan dard 6GK60150AL200WK0 Standard 6GK60150AL200WK1 Conformal Coated RUGGEDCOM APE Modules RUGGEDCOM RX1500PN LM APE1402 Specifications Operating Syst...

Page 37: ...ifications Operating System De bian Linux Processor Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphics Processor DVI D Article Numbers Stan dard 6GK6015 0AL20 0GD0 Standard 6GK6015 0AL20 0GD1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404W7 Specifica...

Page 38: ...ard 6GK6015 0AL20 0GF0 Standard 6GK6015 0AL20 0GF1 Conformal Coated a Maximum combined USB device power consumption is 500 mA at 5 V Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers 6GK6015 0AL10 0AA0 Standard 6GK6015 0AL10 0AA1 Conformal Coated RUGGEDCOM RX1500PN LM Blank Specifications Article Numbers 6GK6015 0AL20 0AA0 Standard 6GK6015 0AL20 0AA1 Conformal Coated 4 2 Insta...

Page 39: ...k of equipment damage Prevent the ingress of water dirts and other debris that may lead to premature equipment failure Always make sure slots are not left empty and open ports are protected with plugs or covers Removing a Module To remove a line module do the following 1 Optional If the device is installed in a rack remove it from the rack 2 Loosen the screws that secure the module 3 Pull the modu...

Page 40: ...nal If the device is installed in a rack remove it from the rack 2 Remove the current module from the slot 3 Insert the new module into the slot 2 1 3 1 Module 2 Chassis 3 Screw Figure 4 3 Installing a Module 4 Tighten the screws to secure the module 5 Optional If necessary install the device in the rack RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 31 ...

Page 41: ...Modules 4 2 Installing Removing Line Modules 32 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 42: ...lation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 A 62 5 W 1500 Vrms for 1 minute be tween coil and contacts 5 3 Operating Environment The RUGGEDCOM RX1512 is rated to operate under the following environmental conditions NOTICE Temperature limits for select line modules may differ from that which can be with stood by the RUGGEDCOM RX1512 Make sure the...

Page 43: ...ing the center of the enclosure c Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings d Non condensing 5 4 Mechanical Specifications Weight Approximately 2 3 kg 5 lb Ingress Protection IP30 Enclosure Aluminum 5 5 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated 122 7 1...

Page 44: ...rawings 96 5 4 1 8 1 150 4 152 4 78 2 50 8 50 8 197 1 174 2 160 5 Figure 5 2 Panel and Din Rail Mount Dimensions 19 7 151 4 102 9 113 3 162 5 Figure 5 3 Line Module Dimensions RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 35 ...

Page 45: ...Technical Specifications 5 5 Dimension Drawings 162 5 40 6 151 8 102 9 113 4 Figure 5 4 Power Module Dimensions 36 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 46: ...art 1 General Requirements Bi National standard with UL 60950 1 UL 60950 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives Directive 2014 30 EU Directive 2014 30 EU of the European Parliament and of the Council of 26 Fe...

Page 47: ...ase EN 61000 3 3 Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standards Immunity for Industrial Environments EN 60825 1 Safety of Laser Produ...

Page 48: ...m pliance could void the user s authority to operate this device 6 1 4 FDA CDRH This device meets the requirements of the following U S Food and Drug Administra tion FDA standard Title 21 Code of Federal Regulations CFR Chapter I Sub chapter J Radiolog ical Health 6 1 5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED Innovation Science and Economic Develop...

Page 49: ...on Test Levels Severity Levels Enclosure Contact 8 kV IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m Signal ports 4 kV 2 5 kHz Note a DC Power Ports IEC 61000 4 4 Burst Fast Transient Earth ground ports 4 kV 4 Signal ports 2 kV Line to Ground 2 kV Line to Line 4 IEC 61000 4 5 Surge DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 Signal ports DC Pow...

Page 50: ... while Class 2 requires error free and interrupted communications Description Test Levels Signal ports 5 kV Failsafe Relay Output HV Impulse DC Power Ports 5 kV Signal ports 2 kV Dielectric Strength DC Power Ports 2 kV Signal ports 4 kV 2 5 kHz DC Power Ports Fast Transient Earth ground ports 4 kV Signal ports 2 5 kV common mode 1MHz Oscillatory DC Power Ports 2 5 kV common 1 kV differential mode ...

Page 51: ...nmental Type Tests Test Description Test Levels Severi ty Levels Shock 30 g 11 ms Class 2 IEC 60255 21 2 Bump 10 g 16 ms Class 1 IEC 60255 21 3 Seismic Method A Level 2 42 RUGGEDCOM RX1512 Installation Manual 07 2019 C79000 G8976 1057 ...

Page 52: ...ttps www siemens com Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...