background image

 

Access Control 
SiPass integrated 

ACC AP Technical Manual 

MP 2.80 

 

 

 

A6V11367717 

 

Smart Infrastructure 

07.09.2020 

 

 

Summary of Contents for ACC AP

Page 1: ...Access Control SiPass integrated ACC AP Technical Manual MP 2 80 A6V11367717 Smart Infrastructure 07 09 2020 ...

Page 2: ...tance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Edition 07 09 2020 Document ID A6V11367717 Siemens Switzerland Ltd 2020 ...

Page 3: ... 7 4 Standards and Guidelines 8 5 Technical Specifications 9 5 1 Battery 10 5 2 ACC AP Controller Diagram 10 5 2 1 Description of Numbered Items in the Diagram 11 6 Installation 12 6 1 OSDP Reader Connections 12 6 2 Wiegand Reader Connections 12 6 3 Mounting 14 6 4 Tamper Function 15 6 5 Configuration 15 ...

Page 4: ......

Page 5: ...Aperio Wireless Locks which can be configured only on ACC AP work in relation to each other Hence it is recommended that the following documents from SiPass integrated Software bundle are read in conjunction ACC AP Technical Manual this document SiPass integrated Firmware Configuration Guide SiPass integrated Configuration Client User Guide Aperio Wireless Lock Support Guide ...

Page 6: ... Standalone unit or as ACC APM PSU unit in 12V 24V voltage options Part Number Type Description S54502 C150 A100 ACC AP ACC AP SiPass integrated IP Door Controller S54502 C152 A100 ACC APM 1220 ACC APM 1220 SiPass IP Controller 12V 2A PSU S54502 C153 A100 ACC APM 2420 ACC APM 2420 SiPass IP Controller 24V 2A PSU ...

Page 7: ...es Please take into account any additional country specific local laws safety standards or regulations concerning installation operation and disposal of the product Refer to a qualified electrician for installation Liability claim Do not make any changes or modifications to the device Use only spare parts and accessories that have been approved by the manufacturer ...

Page 8: ...ons of Directive 2011 65 EU Restriction of the use of certain hazardous substances directive Directive 2014 30 EU Electromagnetic Compatibility directive Directive 2014 35 EU Low Voltage directive The EC Declaration of Conformity is available from your local Siemens sales office or from the address below Siemens Switzerland Ltd Building Technologies Division Theilerstrasse 1a CH 6300 Zug 41 58 724...

Page 9: ...jumper in Vin position Max 200mA jumper in 12V position Inputs Four general inputs Outputs Two relay outputs Max 30V DC 2A One bistable one monostable Four Open collector outputs max load 0 5A One power supply output with Vin max load 2A Resistor Value for Monitored Inputs 22k alarm 11k normal Temperature Range 40 to 55 0C Humidity 250C 80 550C 93 III IEC 60839 11 1 Environmental Class II IEC 6083...

Page 10: ...uld be mounted in the battery socket see item 13 in the AP Controller Diagram with the plus mounted downwards The battery keeps the Audit Trail data intact for about 30 days during any power fail 5 2 ACC AP Controller Diagram See section Description of Numbered Items in the Diagram 10 for detailed information ...

Page 11: ... slot Note that no card is supplied Used for system restore update 13 Battery socket Type CR2032 Note that the supplied battery should be mounted with the plus downwards 14 USB A Full speed future use 15 USB A Hi speed future use 16 Ethernet port RJ45 Network 17 Opening tamper switch Protects for opening the lid 18 USB B connection to computer for setup 19 20 Jumper EOL Reader 1 2 End of line resi...

Page 12: ...ader Connections When connecting Wiegand Readers the A Line of the ACC AP Reader 1 and 2 ports has a fixed 560 ohm pullup resistor Some reader types such as the Siemens AR6111 MX Readers do not have sufficient drive strength to pull the A line low enough For such Readers to work correctly an external 330 ohm pulldown resistor must be tied from the A Line to the negative ve power on the Reader 1 2 ...

Page 13: ...elected there are no designated auxiliary outputs to doors OUT 1 2 3 and 4 are reserved for LED control of the Wiegand Readers Output Wiegand Reader LED OUT 1 Reader 1 Green LED OUT 2 Reader 1 Red LED OUT 3 Reader 2 Green LED OUT 4 Reader 2 Red LED RELAY 1 and RELAY 2 allocation is the same for Wiegand door sets and the corresponding OSDP door sets Relay 1 Door 1 Relay 2 Door 2 Input point allocat...

Page 14: ... unit in such a way that the wiring and connectors can be easily applied There must be a minimum of 10 mm free area around the housing to de mount the lid The dimensions of the layout are shown in the diagram below not actual size Figure 1 ACC AP Controller Mounting ...

Page 15: ... screw If the unit is removed the plastic plug which presses on the tamper switch breaks and the tamper alarm becomes active 6 5 Configuration The ACC AP must be configured locally with the parameters for communication to the SiPass integrated computer where the overall system settings can be made If a reader is connected to the ACC AP and the system settings are configured a card or tag could be ...

Page 16: ...erland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH 6300 Zug 41 58 724 2424 www siemens com buildingtechnologies Siemens Switzerland Ltd 2020 Technical specifications and availability subject to change without notice ...

Reviews: