SMOKE ALARM

User manual

5TC1292-6 

Siemens AG 
Siemensstr. 10 
D93055 Regensburg (Germany)
www.siemens.com      

Type of moun ng 

  Ceiling

Ba ery dura on of the
main power supply          

  5 years

Individual alarm indicator 

  Yes 

Essen al cer fied features covered by the NF mark

            20          5TC1292-6

            0333     Smoke Alarm

            EN 14604:2005 + AC:2008

DoP: 70781A-WA-DoP

h ps://support.industry.siemens.com     

Iden fica on

Main power supply  

  Internal to the device (ba ery)

Low ba ery mode

When the ba ery is running low, the smoke alarm will indicate this with a 
repe

ve beep and flash for approximately 30 days. Replace the ba eries by 

one of the recommended ba ery types described in chapter “Product 
specifica ons” on page 1. Take the smoke alarm from the moun ng plate by 
turning it counter clockwise and remove the empty ba ery. Install the new 
ba ery as illustrated in chapter “Ac va on“ on page 3.

 

Make sure that the 

ba ery is properly connected. Test the alarm for correct opera on using the 
test facility, whenever the ba ery is replaced.

Fault warning mode

When the smoke alarm is not func oning properly, it will turn into the fault 
warning mode. Try cleaning the smoke alarm (see paragraph “Maintenance“) 
or replace the smoke alarm!

Maintenance

Test this smoke alarm weekly for correct opera on using the test facility. If 
the smoke alarm func ons correctly, it will generate a loud beep. Due to 
the loudness of the alarm, make sure that you always stand at arm's length 
distance from the unit when you are tes ng. If the smoke alarm does not 
generate an acous c signal, the smoke alarm must be replaced 
immediately!

Clean the smoke alarm at least once per month to remove dirt, dust or 
debris. Use a vacuum cleaner with a so  brush and vacuum all sides and 
covers of the smoke alarm. Do not remove the top cover of the smoke 
alarm to clean it inside.

Do not a empt to repair this smoke alarm. If the smoke alarm shows a 
damage related to its func onality, it must be replaced!

Trouble shoo ng: False alarm is o en caused by dust or steam.

Recycling and disposal

  The WEEE symbol means that this product and ba eries must be 
  disposed separately from other household waste. When they reach   
  their end of life, take them to a designated waste collec on point in 

your area to guarantee a safe disposal or recycling. Ba eries must be r emoved 
from the product. Protect the environment, human health and natural 
resources!

Transport

Product is not classified as a dangerous good, however observe transporta on 
informa on concerning dangerous goods regula ons!

Note: During the transport, the product must be deac vated. Remove the 
ba ery and insulate the ba ery poles.

Service

Cer fied by AFNOR Cer fica on (www.afnor.org). For advise from experts and 
firefighters, go to: h ps://cer fica on.afnor.org/securite/nf- securite-
incendie-domes que

The CE mark affixed to this product confirms its compliance with the 
European Direc ves which apply to the product and, in par cular, its 
compliance with the harmonized specifica ons of standard EN 14604:2005 
rela ng to Construc on Products Regula on 305/2011.
The NF – DOMESTIC FIRE SAFETY mark provides assurance as to safety and 
consistent quality inspected by experts. Through its rigorous and exhaus ve 
inspec ons (holder's quality management system, product inspec ons, audits 
and monitoring tests, etc.), the NF mark represents a comprehensive 
guarantee for consumers that the cer fied products are compliant. The NF – 
DOMESTIC FIRE SAFETY mark confirms the product's compliance with 
cer fica on rules NF 292.

ESSENTIAL CHARACTERISTICS: PASS
Nominal ac va on condi ons / sensi vity / response delay (response  me) 
and performance under fire condi ons - Opera ng reliability - Tolerance to 
supply voltage - Durability of opera onal reliability and response delay, 
temperature resistance, vibra on resistance, humidity resistance, corrosion 
resistance, electrical stability.

Opera ng mode  

Visual signal (flash) 

Acous c signal (beep)  

Descrip on mode

Normal  

1 x per 32 seconds   

None  

Device is func oning properly

Test  

1 x per second (3 x), pause of 1,5 seconds  

1 x per second (3 x), pause of 1,5 seconds   Device is being tested          

Alarm 

1 x per second (3 x), pause of 1,5 seconds  

1 x per second (3 x), pause of 1,5 seconds   Device has detected smoke          

Low ba ery  

1 x per 32 seconds 

1 x per 32 seconds 

Ba ery is running low

Fault warning  

1 x per 32 seconds 

1 x per 32 seconds 

Device is not func oning properly