background image

OWNER'S MANUAL

PJ-Net Organizer

MODEL No.

 

POA-PN30

LINK

POWE

R

ACT

PJ-Net

Organizer

Summary of Contents for PJ-Net Organizer POA-PN30

Page 1: ...OWNER S MANUAL PJ Net Organizer MODEL No POA PN30 LINK POWER ACT PJ Net Organizer ...

Page 2: ...modifications should be made you could be required to stop operation of the equipment Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Trademarks PJ Net Organizer is a trademark of Sanyo Electric Co Ltd Ethernet is a registered trademark of Xerox Corporation Microsoft Windows Windo...

Page 3: ...It may cause fire or an accident depending on the change of environment The CE Mark is a Directive conformity mark of the European Community EC Expression Abbreviation The word projection monitor or PJ monitor found in this manual means LCD projec tion monitor provided with PJ Net Organizer unless otherwise noted The OS of the computer and the web browser described in this manual is Windows XP Pro...

Page 4: ...ect a display mode and login 24 3 Display of main setting page 25 How to use the setting page 26 Initial setting 28 Network PIN code setting 29 Date and time setting 29 Network configuration 30 E mail setting 31 Examples Type and contents of alert mail 33 SNMP setting 35 Chapter 4 Controlling the Projection Monitor 37 Power control and status check 38 Controls 40 Input 40 System 41 Image adjustmen...

Page 5: ...itor 55 Change the mode of the registered projection monitor 56 Status 56 Conf Change page in the light mode 57 Controlling all together 57 Setting all together 57 Chapter 5 Use of Serial Port 59 Serial port setting 60 Setting examples for the serial control 61 Control examples 62 Use of telnet 64 Control the projection monitor with telnet 66 Chapter 6 Appendix 67 Examples of connection 68 Web bro...

Page 6: ...6 ...

Page 7: ...7 PJ NET ORGANIZER OWNSER S MANUAL ENGLISH 7 1 Chapter 1 Preparation Describes features and operating environment of this product ...

Page 8: ...You ve got Mail PJ2 PJ1 Web Management function p 37 With this function you can monitor projection monitor functions such as power sta tus lamp status input mode signal condition lamp use time etc through the network by using the web browser installed on your computer PC4 PC3 PC6 PC5 PC1 PC2 Turn on PJ2 PJ2 PJ1 SNMP Agent function p 35 The function to send informa tion of the projection moni tor t...

Page 9: ...nction to manage the con dition of projection monitors in the network by using the SNMP protocol The managing computer needs to provide an SNMP managing software Refer to the owner s manual of the PJ Net Manager sup plied separately for further details PC6 PC4 PC5 SNMP Manager Trap Trap You received a trap PJ2 PJ1 PJ4 PJ3 Control port ready for external equipment p 59 This product provides a seria...

Page 10: ... Network must handle Ethernet correctly and accept TCP IP protocol Computer The computer must provide a 10Base T or 100Base TX network card Web browser application Microsoft Internet Explorer version 5 0 5 5 or 6 0 Netscape Navigator version 6 2 7 0 or 7 1 Used to control and set up the projection monitor The layout of pages in the browser may slightly differ from each type of application or opera...

Page 11: ...ce The limitation 1 of connection between this product and hub or computer Suitable LAN cables are limited by length and type as follows Connection Type of usable LAN cable Maximum length Network Unit Hub UTP Straight Cable with category 3 or 5 2 100m Network Unit Computer UTP Cross Cable with category 3 or 5 2 100m 1 There may be other limitations depending on your network environment or LAN spec...

Page 12: ...12 Chapter 1 Preparation ...

Page 13: ...13 PJ NET ORGANIZER OWNSER S MANUAL ENGLISH Chapter 2 Installation 2 Describes how to install the Network Unit and configure the network ...

Page 14: ...nt this product onto the projection monitor 2 Connect the LAN cable and join it to the network 3 Configure the network of the Network Unit 4 Set the network PIN code Flow of installation The preparation is complete to control the projection monitor connected to the net work At next step set up and control the projection monitor via the network by using the web browser installed on your computer Pl...

Page 15: ...is lights up red when the network function is set ON in the projection monitor menu LAN port Connecting the LAN cable p 17 Connector plug Connecting to the terminal on the projection monitor p 16 Mounting screws Mount by using a coin etc p 16 LINK indicator This lights up orange when the Network Unit is connected to the network correctly ACT indicator This turns on and off when sending or receivin...

Page 16: ...s into a projection monitor otherwise it may damage the product Connect the AC cord after connecting the LAN cable and computer 2 Installation and network configuration Caution 注意 1 Disconnect the AC plug from the projection monitor 2 Insert plug on this product to the option connector 3 Tighten two screws by using a coin etc LINK POWER ACT PJ Net Organizer Option connector ...

Page 17: ...itor 2 Connect the UTP straight cable to the LAN port on the Network Unit 3 Connect the UTP straight cable to the hub Use the UTP cross cable when you connect the computer and projection monitor directly not using the hub When you connect the projection monitor into the 10Base T network use cable with category 3 or 5 When you connect the projection monitor into the 100Base TX network use cable wit...

Page 18: ...lly If not activated the product may not have been installed correctly Please check item Mounting p 16 Configure the network Before performing the network configuration prepare network address numbers IP Address Subnet Mask Default Gateway DNS assigned to the projection monitor Ask your network administrator for the network address For example the case where the following network address is set up...

Page 19: ...n the screen Completing of installation Now the installation is complete The IP address of this projection monitor is set to 192 168 1 201 Item Description IP address Sets IP address of the projection monitor Sub net Sets Subnet mask Normally sets 255 255 255 0 Gateway 1 Sets IP address of the default gateway Router DNS 2 Sets IP address of the DNS server Must be set when using the e mail function...

Page 20: ... means no network PIN code is set 1 Displaying network PIN code menu Select network menu and then select Network PIN code sub menu Press SELECT button to display the Network PIN code entry pallet 2 Entering the network PIN code To enter the network PIN code use pointer buttons 7 8 on the projection monitor or the remote control 3 Fixing the network PIN code After entering a 4 digit number press SE...

Page 21: ...ting menu on the projection monitor Please see item Network configuration for further information p 18 2 Make sure that there is no network equipment set with the same IP address in the network before connecting to the network 3 When installing other projection monitors follow the above steps to change the IP address and connect to the network In case of installing the projection monitor with Netw...

Page 22: ...22 Chapter 2 Installation ...

Page 23: ...ic Setting and Operation 3 Describes basic operations and settings for controlling the pro jection monitor by using the web browser It is required that computer and projection monitor is connected to the network and the network address is properly configured ...

Page 24: ...y clicking on the text link Standard Mode For computer display displays graphical menus and settings This mode is recommended for stan dard use Light Mode Displays with 200 x 300 dots This mode is optimized for use of the handheld computer PDA etc It is also convenient if the network traffic is heavy If the setting page has set the password the authentication window will appear In this case type u...

Page 25: ...ntrol the projection monitor with the graphic mode If your computer does not have follow to the message on the control page to install the Macromedia Flash Player For further product information or installing see the Macromedia homepage http www macromedia com Setting page Displays the control and setting items according to the selected menu Returns to Display Mode selection page p 24 Main menu Fo...

Page 26: ...r type the number onto the text box directory and then click Set button Each item has a valid setting range respectively Example of the Setting Page The value in the text box indicates current value Each item has a valid setting range The setting value exceeding this becomes invalid Some control items can not be used depending on the selecting input mode or functions of the pro jection monitor you...

Page 27: ...but ton The value changes quickly when keeping pressing or button Pull down menu setting Select an item with pull down menu button and then click Set button or Select an item by clicking or button Radio button setting Select an item by selecting a radio button Check box setting Select items by ticking on check boxes Type of the setting pallet How to use the setting page ...

Page 28: ... product is mounted is displayed on the page Item Description Model name Indicates the model name of the projection monitor provided with the Network Unit PIN code Sets the PIN code to login the setting page p 29 Temperature Switches display temperature unit Centigrade or Fahrenheit Time setting When clicking AUTO button the time which is set on your computer is set to the Network Unit Date Sets d...

Page 29: ...rk Enter a 4 digit numeric number as the network PIN code onto the text box and click Set button The Network Unit begins restarting and it takes about 20 seconds Close Quit the web browser and access to the login page again in 20 seconds This is to perform the login authentication firmly The default network PIN code 0000 means no network PIN code is set When you connect the projection monitor with...

Page 30: ...ou do not use the function E Mail alert 3 If you use the DNS server register the host name registered to the DNS server as a projec tion monitor name You can access with this projection monitor name from any computers in your network If you do not use the DNS server access with the assigned IP address to the projection monitor Item Description IP address Sets IP address of the projection monitor S...

Page 31: ...Sets e mail address of the user to send mail when the projection monitor has an abnormality 1 Setting SMTP server and administrator address Set the server name or IP address of the SMTP server 1 and administrator address The administrator address is set to Reply To address sent from the projection monitor 1 The SMTP server is a server for sending E Mail Please contact your network administrator to...

Page 32: ... alert mail Click Option sub menu tab Check the condition items under which alert mail will be sent and click Set button Please refer to item Examples Type and contents of alert mail described on the next page Check Delete Option 1 When PJ lamp is off When the life span of lamp is reached When internal PJ power circuit is failed When internal PJ temperature is too high 2 When PJ is turned off with...

Page 33: ...ITLE Message from PJ monitor 11 03 2004 00 59 PJ monitor Model Name model name TCP IP 192 168 1 201 PJ monitor Name Proj_05 It sends you following message The PJ monitor lamp is turned off because internal PJ monitor temperature is too high Wait for Temperature Warning Indicator turned off and then turn the PJ monitor on again If the Indicator continues flashing check the air filter for dust accum...

Page 34: ...2004 00 59 PJ monitor Model Name model name TCP IP 192 168 1 201 PJ monitor Name Proj_05 It sends you following message The life span of lamp is reached When the lamp use time reached preselect lamp use time The Network Unit sends a free message when the lamp use time reaches the prese lected lamp use time It can be used for preparation of the lamp replacement and the maintenance required TITLE Me...

Page 35: ...m Item Description Contact Enter user name of the projection monitor etc optional Place Enter place of the projection monitor optional Community name refer Enter community name read only Default name is public Item Description Community name Enter community name to send Trap Default name is public Trap address Enter IP address of the SNMP manager computer to receive Trap PJ information Trap SNMP i...

Page 36: ...hecking the registered trap address and deleting the address To delete the address tick check box in front of the IP address and click Delete button Trap check delete 1 When PJ lamp is off When the life span of lamp is reached When internal PJ power circuit is failed When internal PJ temperature is too high 2 When PJ is turned off with power ON OFF but ton When Power management function turns PJ l...

Page 37: ...37 PJ NET ORGANIZER OWNSER S MANUAL ENGLISH Chapter 4 Controlling the Projection Monitor 4 Describes controlling and setting of the projection monitor by using the web browser ...

Page 38: ...y button PJ temp Inside temp A Displays the temperature around the intake vent of the projection monitor Sensor A Inside temp B Displays the internal temperature of the projection monitor Sensor B The warning icon will appear if the temperature exceeds a specified value Check if there is no object to obstruct the airflow around the intake or exhaust vent It might be airfilter clogged Clean up the ...

Page 39: ... monitor detects abnormal temp and is cooling down itself Standby after Abnormal Temp Projection monitor detects abnormal temp and sets into standby mode Power failure Power failure has occurred inside the projection monitor Projection monitor is turned off Disconnect the AC cord and ask servicing to a qualified service personnel If the power failure occurs on the projection monitor Power fail ure...

Page 40: ...efer to the projection monitor s owner s manual When the projection monitor is in standby only the timer on the setting menu is effective others are inactive Item Description Input Selects input mode of the projection monitor 1 to 5 Source Selects signal source of the input Input 1 RGB PC Digital RGB AV DHCP Input 2 RGB Analog Input 3 RGB Video Video conference Y Pb Cb Pr Cr Input 4 Auto Video Vid...

Page 41: ... meet the input signal are listed Available selection when the VIDEO S VIDEO input Item Description AUTO It automatically switches to the proper color sys tem of the input signal The selectable color systems are PAL SECAM NTSC NTSC4 43 PAL M and PAL N Available selection when the Y Cb Pb Cr Pr input Item Description AUTO It automatically switches to the proper scanning system of the input signal T...

Page 42: ...cture sharpness 7 7 When changing the value of the white balance the color temp indi cates Adj Item Description Gamma Adjusts brightness of darker part of the picture 7 7 Auto grayscale Switches automatic grayscale mode ON OFF Reset Resets the Image adjustment to previous levels Store Stores the Image adjustment values Select an item Image from the pull down menu and click Save button Load Loads t...

Page 43: ...Store Stores the sound adjustment values Treble Bass and Balance Click Store button to store them into the Personal mode Reset Resets the setting values Treble Bass and Balance to the predefined values of the selected audio system Volume Adjusts the sound volume from the speakers 0 63 Mute Suppresses the sound ON OFF Menu This function is to control the On screen menu of the projection monitor Swi...

Page 44: ...the number of total dots in the horizontal period Clamp Phase Adjusts the phase of the clamp Display area Horizontal Adjusts the image area horizontally Vertical Adjusts the image area vertically Item Description Position Horizontal Adjusts the horizontal position of the screen Vertical Adjusts the vertical position of the screen Reset Rests the PC adjustments to the previous levels Mode Store Sto...

Page 45: ... OFF No operation shut off timer Enables or disables the shut off timer if the period of no operation is continued for more than 3 hours ON OFF Remote control ID Sets the remote control ID Code 1 Code 8 On start Sets the power on mode when connecting the AC cord to the outlet ON OFF Key lock Sets the prohibition of the controls with the remote control or the keys on the projection moni tor or both...

Page 46: ...ction is not effective for the settings of the network unit Network address settings e mail settings etc Freeze Sets the image to freeze mode ON OFF Item Description Power management Sets into the selected power management mode OFF Ready or Shut down if the input signal is interrupted and no control key is pressed for the specified period of time The specified time can be set 1 to 30 min Lamp cont...

Page 47: ...e item Set of Save Delete Name this set number onto the Memo text area Up to 18 characters can be used for the Memo 3 Click Save button to store the cur rent setting and name into the selected set number To remove the saved setting select the set number with pull down menu button and then click Delete button You can store up to 20 Totalsave1 to Totalseva20 sets of settings into the Network Unit In...

Page 48: ... set Select your desired set number Totalsave1 to Totalsave20 with the pull down menu button of Load Set and then click Load button The setting values of the selected set number are applied to the current settings Select a set number If the contents of the saved set are not matched for the inputs equipped on the projection monitor the invalid alert message may be displayed Click Stop button to can...

Page 49: ...cified date select date entry with radio button and then type the date with Year Month Date format Ex Type 2004 12 20 if you specify December 20 2004 Timer setting This page is to set the timer to turn the projection monitor off or on at a programmed day date and time Follow the steps below for setting Click Timer on the main menu Present time set on the Network Unit Initial Setting SNMP Setting I...

Page 50: ...er the set timer event Repeat steps 1 to 4 for another timer event setting Change the event mode On the event list appearing by clicking Check but ton click on the event you want to delete disable or enable Click Cancel Delete Timer ON or Timer OFF button on the popup pallet Check the timer events To check the set timer events click Check button The timer event lists are listed The event with gray...

Page 51: ... below event 3 turns on the projection monitor so next event 4 also turning on projection monitor will not be effective because the projection monitor is already turned on Similarly when the projec tion monitor is turned off by event 5 event 6 OFF will not be effective in turning it off again But these secondary events event 4 and event 6 will become effective if a person turns off the projection ...

Page 52: ...ys the use time of the lamp Timer Displays the timer setting status ON Timer has been set OFF No timer setting Initial Setting SNMP Setting Information Timer Multi Control Network Save E mail Setting Setting Control PC Adj Power Status Icon display background Status White Yellow Blue Lamp on Normal White Yellow Red Lamp on Lamp is being used over a specified use time replace lamp immediately Gray ...

Page 53: ...network Click Multi Control on the main menu to display the control page Note To control the multiple projection monitors each projection monitor must have the same PIN code PC6 PC4 PC5 Select Input 2 for PJ1 to PJ4 PJ2 PJ1 PJ4 PJ3 Example of multi control Switches on and off the multi control function Initial Setting SNMP Setting Information Timer Multi Control Network Save E mail Setting Setting...

Page 54: ...ion ON Starts multi control function The multi control menu will appear when setting ON These items of menu are linked to the main menu The multi controllable menus are Power Status PC adjustment Control Setting E mail setting Timer and SNMP setting Click each menu and per form setting and adjustment The word Multi Control appears on the each control page during the multi control is operating This...

Page 55: ...age no Click here to close the sub menu Conf Change When you click on a listed IP address the login page for the selected projection monitor will be displayed with a new window Items Description IP address Enter IP address of the projection monitor to con trol Memo Enter projection monitor name or installed location etc Status Confirmation of registered projection monitor To check the registered i...

Page 56: ...If the registered projection monitor is not connected to the network it will take some time to complete the multi control operation because of waiting for the response from each registered projection monitor Change the mode of the registered projection monitor To change the mode of the registered projection monitor select a mode with the pull down menu button under the IP address of the target pro...

Page 57: ...justment Control and Setting can be controlled all together Set ON the multi control setting and adjust controls of each menu The setting value is applied to the registered projection monitors sequentially This is effective only if the mode of the registered projection monitor is set to Control Setting all together E mail setting SNMP setting and Timer can be set all together Set ON the multi cont...

Page 58: ...58 Chapter 4 Controlling the Projection Monitor ...

Page 59: ...59 PJ NET ORGANIZER OWNSER S MANUAL ENGLISH 5 Chapter 5 Use of Serial Port Describes controlling the external equipment connected with the RS 232C port ...

Page 60: ...speed for serial port select with the pull down menu 300 115200 Parity Parity check the ways for error detecting of the transferred data None Odd Even Stop bit Stop bit Select the end of communication 1 or 2 Flow control Ways for communication flow None Xon Xoff RTS CTS Data length Selects the length of data 7 or 8 Serial control Selects equipment to control External or PJ monitor External Used to...

Page 61: ...the equipment connected to the serial port from the computer Serial Control Selects External Port number Sets according to the computer specified port no Do not use port number 10000 2 Other Settings Sets according to the communication condi tion of the equipment Setting for controlling the projection monitor from the serial controller connected to the serial port Serial Control Selects PJ monitor...

Page 62: ...n monitor not provided with the network function through network Control examples Example 1 Controlling AV equipment through network PC5 Playback DVD PJ2 DVD Player Video Audio RS 232C serial cable PC5 Turn on the PJ1 PJ2 PJ1 LAN cable RS 232C serial cable LAN cable ...

Page 63: ...h the serial controller through the serial port RS 232C Use proper serial cable depending on the connected equipment port specification Please refer to Port Specification of the serial port specification of this product p 76 PJ2 PJ1 PJ3 Serial controller Control examples RS 232C serial cable ...

Page 64: ...t by clicking any of the items on the serial port setting page p 60 4 Change the serial port setting to be the same communication condition as the connected external equipment and then click Set button The following example setting is for our projection monitor communication condition When controlling our projection monitor set as follows Control For example in case of using theTelnet application ...

Page 65: ...nter key C00 is a command to turn the projection monitor on The extra projection monitor will be turned on To disconnect the communication press Ctrl key and key at the same time 1 Further instructions about the telnet application please see the on line guide on your com puter 2 The commands are defined by each product independently so please consult the manufac turer or sales dealer for further i...

Page 66: ...Use the IP address assigned to the pro jection monitor After the communication is established type the password PIN code and the com mand for controlling the projection monitor and then press Enter key The table below shows the typical command lists for controlling the our projection monitor and please consult your local dealer for further information of another com mands Command Function C00 Powe...

Page 67: ...67 PJ NET ORGANIZER OWNSER S MANUAL ENGLISH Chapter 6 Appendix 6 Examples of connection Web browser setting Technical data Q A ...

Page 68: ...lt Gateway DNS Computer Name PC05 IP Address 192 168 0 5 Subnet Mask 255 255 255 0 Default Gateway DNS Hub Projector Name PJ01 IP Address 192 168 0 2 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 DNS 0 0 0 0 Computer Name PC05 IP Address 192 168 0 5 Subnet Mask 255 255 255 0 Default Gateway DNS UTP cross cable Connecting the projection monitor PJ01 to the control computer PC05 via the hub When...

Page 69: ...way 192 168 200 1 DNS 192 168 201 1 IP Address 192 168 200 1 IP Address 192 168 10 1 IP Address 192 168 100 1 Computer Name PC05 IP Address 192 168 10 5 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 1 DNS 192 168 201 1 Computer Name PC10 IP Address 192 168 10 10 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 1 DNS 192 168 201 1 Computer Name PC51 IP Address 192 168 10 51 Subnet Mask 2...

Page 70: ...e the JavaScript please see further instructions on the next page Proxy setting In some cases your web browser is set up to use the proxy server for the internet or intranet connection In this case when you install this product into the local network you should set up the proxy setting of web browser preference correctly Especially when connecting the projection monitor and computer with a UTP cro...

Page 71: ...er v 6 0 ActiveScript setting Select Internet Options menu from Tool menu on the web browser and then select Security tab and click Customize Level button On the security setting window scroll down and find the Scripting item make sure that Enable is selected in item Active Scripting Web browser setting ...

Page 72: ...nnection from the local area network check the item Use a proxy server and enter the proxy server address and port correctly in the proxy settings window For further instruction please consult your network administrator Not using proxy server Uncheck the item Use a proxy server If you connect the projection monitor to the computer directly with UTP cross cable this must be unchecked To designate p...

Page 73: ...rowser setting Netscape Navigator v 7 0 JavaScript Setting Select Preference menu from Edit menu on the web browser and then select the item Advanced Scripts Plugins in the Category column Make sure that the Enable JavaScript for Navigator is checked ...

Page 74: ...cal area network select the item Manual proxy configuration Enter the proxy server address and port num ber correctly on HTTP Proxy item For further instruction please consult your net work administrator Not using proxy server Select the item Direct connection to the Internet in the proxy setting window If you connect the projection monitor to the computer directly with UTP cross cable this must b...

Page 75: ...ion TCP IP Serial interface RS 232C Baud rate 0 3 1 2 2 4 4 8 9 6 19 2 28 8 57 6 115 2 Kbps Flow control Hardware flow control RTS CTS Xon Xoff Parity check Odd Even Terminal D sub 9 pin Male Power source Supplied from the projection monitor Power consumption 3 0 watts Dimensions W x H x D 4 13 x 5 20 x 1 32 105 x132 x 33 6 x mm Weight 0 57 lbs 258 g Built in battery Lithium battery Type CR2032 3 ...

Page 76: ...e data 4 not used 5 not used 6 RD Receive data 7 not used 8 not used 1 2 3 4 5 6 7 8 8 pin modular connector RJ 45 Pin No Signal Function 1 CD Carrier detection 2 RXD Receive data 3 TXD Transfer data 4 DTR Data terminal ready 5 Ground Ground 6 DSR Data set ready 7 RTS Request to send 8 CTS Clear to send 9 not used 1 2 3 4 9 8 7 6 5 D sub 9 pin connector RS 232C ...

Page 77: ...rong network configuration of the computer Check the network configuration of the computer 5 The Network Unit is used with the default setting p 18 6 The proxy setting of the web browser is not set correctly p 70 7 The computer does not provide TCP IP protocol Q No setting page in my web browser Is the problem in the network or in the projection monitor I would like to find out the problem whether...

Page 78: ... gateway router to restrict the accessing from the computer For further information please consult your network administrator Q Can I access the projection monitor installed on the company s local area network from a remote location A There are some ways to access to the projection monitor in the LAN but you must consult your network administrator for security reason Use of modem Connect to the co...

Page 79: ...esigned to control up to 100 sets but it depends on the network environment Password Login Q What should I do when I forget the password network PIN code A You can set again by selecting Network PIN code sub menu from Network menu on the projection monitor For further information please see item Network PIN code setting p 20 Q Can I register the setting page as a web browser Favorites or Bookmarks...

Page 80: ...environment in which both the projection monitor and computer are placed It may take much time to complete the page display if network traffic is heavy Please consult your net work administrator You can select the Light mode for displaying pages quickly p 24 Q I use many of the projection monitors in the network How can I use names of the projection monitors to recognize each projection monitor in...

Page 81: ...uthentication depending on the SMTP server This product does not support this kind of SMTP server Others Q Can I develop a driver to control external serial equipment A This product does not provide any driver software To control the external equip ment connected to the extra serial port it should be required to clarify the com mands and communication condition defined by each equipment If they ar...

Page 82: ...ossible to update the firmware through the network It is required to have a special tool for the updating For further information please consult your local dealer The version number of the firmware is indicated on the lower part of the Initial Setting page Version of the firmware ...

Page 83: ...P address is set 192 168 x x the Subnet Mask should be set 255 255 255 0 for example Rule2 The start address xxx xxx xxx 0 and the last address xxx xxx xxx 255 of the IP address must not be assigned to any other equip ment These address numbers are reserved Rule3 The IP address must correlate to a network number If network numbers are different between the equipment they cannot estab lish communic...

Page 84: ...Printed in Japan 1AA6P1P4814 IDZL SANYO Electric Co Ltd ...

Reviews: