background image

User Guide

1

Use precautions to avoid damages to the product or injuries of users. Any actions against following contents will cause serious 

issues such as malfunction, electric shock, or burn.

USE DC12V ONLY

DC12V

DO NOT USE AC INPUT

AC  INPUT

Do not cut or rejoion wires while product 

is connected wth live power source

Maximum driver quantity per serial 

connection is limited. Failure causes overload 

of current and damages to the product

Refer to ‘WIRE THICKNESS’ table to use proper 

LED module

Failure will cause dimmed output

module is limited. Refer to ‘CONNECTION 

WITH POWER SUPPLY’ on page 2

Do not use the product under circumstances 

listed below
 - High temperature spots over 60˚C (140˚F)

 - Spots draw extreme moisture or dust

Avoid performing installation under rain or 

high humidity for outdoor use

Do not perform actions listed below
 - Alter or modify

 - Touch LED lamps with sharp objects

 - Put glue or silicon over the LED lamps

PRECAUTIONS

PREPARATION

PREPARE CHANNELS

1. Clean moisture and dust inside

2. Make holes

3. Use bushing to protect wires

2. Make holes for wires from modules to SMPS.

3. Without bushins, wires will easily be cut and short-circuit will occur.

SUPPLIES REQUIRED

TOOLS REQUIRED

Wire Nuts, Cable Ties, IDC Connectors, VCTF(PLTC) Cable,

(Optional : Silicon and Screws)

Wire Stripper, Drill, Screw Driver, Wiper

STAR C0640

PHYSICAL

ELECTRICAL

Current dissipation: 110 mA (Colored: 76 mA)

Power Consumption: 1,08 W (Colored: 0,92 W)

Operating power : DC 12V

Maximum serial connection : 25 modules

Electronic dimming control supported

Constant current drive, Reverse voltage protection

THERMAL

Cooling : Ambient air

Maximum operating temperature : 60˚C (140˚F)

Minimum operating temperature : -25˚C (-13˚F)

Maximum storage temperature : 60˚C (140˚F)

Minimum storage temperature : -30  C (-22  F)

SPECIFICATIONS

IP63

  

FARD lighting GmbH     Seestrasse 20      D - 14974 Ludwigsfelde OT Genshagen

Tel. +49 - (0)3378 / 2003-0       Fax +49 - (0)3378 / 2003-29

[email protected]       www.fard-lighting.de

Summary of Contents for STAR C0640

Page 1: ...s with sharp objects Put glue or silicon over the LED lamps PRECAUTIONS PREPARATION PREPARE CHANNELS 1 Clean moisture and dust inside 2 Make holes 3 Use bushing to protect wires 2 Make holes for wires from modules to SMPS 3 Without bushins wires will easily be cut and short circuit will occur SUPPLIES REQUIRED TOOLS REQUIRED Wire Nuts Cable Ties IDC Connectors VCTF PLTC Cable Optional Silicon and ...

Page 2: ...imum lighting output while maintaining lowest unit cost Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface LAYOUT DENSITY GUIDELINES CONNECTION WITH POWER SUPPLY Output W Model Name Recommended Extension Wire Output A Maximum Length 30W 2 5A PSGE 0030 12 5M 15FT VCTF1 25 AWG18 60W 5A PSGE 0060 12 5M 15FT VCTF2 0 AWG14 120W 10A PSGE 0120 12 5M 15FT VCTF2 0 AW...

Page 3: ...34 6 22 34 41 1000 mm 1 DETERMINE LAYOUT Refer to LAYOUT DENSITY GUIDELINES on page 2 to determine spacing and amount of LEDs required SUPPORTS FOR OUR SIGNMATES Ask us to obtain accurate layout Stroke Width Channel Depth 2 PEEL AND STICK Using predetermined layout and LED placement from step 1 remove 3M tape on the back of modules attached on the surface CAUTION When handling the module avoid pre...

Page 4: ...dules that light and the modules that don t light Check this connection Beginning of a leg lights but the entire leg does not light or lights intermittently S LED is designed so if one module fails it will not cause the entire sign or leg to go out If one module does not light but all others in the leg do replace this module with a new one One module does not light but all others in the leg light ...

Reviews: