Biometric Reader

user manual

SSA-R2010
SSA-R2020
SSA-R2040
SSA-R2011
SSA-R2021
SSA-R2041

imagine

 the possibilities

Thank you for purchasing this Samsung product.
To receive more complete service, 
please visit our website.

www.samsungsecurity.com

Summary of Contents for SSA-R2010

Page 1: ...r manual SSA R2010 SSA R2020 SSA R2040 SSA R2011 SSA R2021 SSA R2041 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com ...

Page 2: ...l injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers filled with water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case...

Page 3: ...the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with cart stand tripod bracket or table specified by the manufacturer o...

Page 4: ... Line Connection INITIALIZATION 20 20 Initializing the system using the DIP switch 21 Display and Operation Status of Reader Register 22 To register delete the master ID card 22 Communication Address Setup 23 Reader Mode and Authentication USER MANAGEMENT 24 24 Registering the ID 24 To register the ID card along with the fingerprint 25 To delete ID OUTPUT FORMAT 26 26 WIEGAND Output Default OTHER I...

Page 5: ... card ID will be transferred to the controller RF FINGER Mode As soon as the fingerprint is authenticated the corresponding card ID will be transferred to the controller For a person whose fingerprint is not registered the product will automatically switch to RF Only mode Error Signal Output If the product fails to authenticate a fingerprint or unregistered card it will produce an error signal for 50...

Page 6: ...n WHAT S INCLUDED Check if the following items are included in the product package Main Unit Wall Mount 3 x 30mm Screws x2 3 5 x 12mm Screws x2 3 x 6mm Screw x1 6 x 30mm Plastic Anchors x2 x Gn Cables x4 Quick Guide CD Manual t Gj Master Card x1 ...

Page 7: ...ront Panel LED Displays the status of the system operation Fingerprint Sensor Fingerprint scanner module Card Recognition Present a card to the marked area and the product starts reading it Speaker Sounds a voice comment according to the user manipulation ...

Page 8: ...ector Can be connected to the Wiegand input and RS 485 communication cables 4 8 PIN Connector Can be connected to the Wiegand output and signal output cables 5 2 PIN Connector Can be connected to the power cable 6 RJ45 Connector Used in TCP IP communications 7 DIP Switch Used to initialize the system or specify the communication addresses 2 5 3 4 6 7 ...

Page 9: ... 485 A Yellow RS 485 B RS 485 B Gray 8 PIN Connector I O Pins Signal Cable Color Wiegand DATA 0 DATA 0 Green Wiegand DATA 1 DATA 1 White ERROR SIGNAL OUT ERROR SIGNAL OUT Orange OK SIGNAL OUT OK SIGNAL OUT Orange with Black Stripes TAMPER OUT TAMPER OUT Purple EX_LED_CONTROL EX_LED_CONTROL Blue with White Stripes EX_BUZZER_CONTROL EX_BUZZER_CONTROL White with Red Stripes EX_SYS_CHANGE_IN EX_SYS_CH...

Page 10: ...Conductor Unshielded 2 Wiegand I O Product Controller connected External Reader Product Belden 9512 22 AWG 4 Conductor Shielded Belden 9514 22 AWG 8 Conductor Shielded 3 Signal I O Controller Product Belden 9512 22 AWG 4 Conductor Shielded Belden 9514 22 AWG 8 Conductor Shielded 4 RS 485 Cable Converter Host PC Converter Product Belden 9829 24 AWG 2 twisted pair Shielded ...

Page 11: ...ors as appropriate and use one screw to fix the Wall Mount with the product TERMINATION RESISTOR A resistor is inserted for line s impedance matching to prevent distortion and reduction in RS 422 or RS 485 long distance data communications which is referred to as termination resistor Note that termination resistors of lower than 90 are not allowed neither more than one termination resistor is accep...

Page 12: ...current flow will introduce some noise and interference to communications It is recommended to connect ONLY one end of the shield wire of the communication cable to the grounding system If you can locate an earth grounding point nearby connect one end of the shield wire to that point If you could hardly locate an earth grounding point nearby connect one end of the shield wire to the chassis ground ...

Page 13: ...ontroller Hub Authentication Success Authentication Error DATA1 DATA0 DC 12V GND TAMPER CLK DATA Wiegand White with red stripes Blue with white stripes Gray with red stripes Orange with black stripes Orange White Green Red Black Purple 26bit 34bit Wiegand DATA1 DATA0 DC 12V GND External Reader RJ45 Sky Blue Pink PC RS 485 A RS 485 B Yellow Gray ...

Page 14: ...he buzzer control is working the product keeps sounding the beep The controller can use the I O settings to set the buzzer control so that it sounds an additional beep for authorized or unauthorized access upon user authentication Furthermore you can handle various situations according to the I O settings of the controller For more information about the I O settings of the controller refer to the ...

Page 15: ...ontroller can transfer the authentication error event to the operating software program Furthermore you can handle various situations according to the I O settings of the controller Connection of Authentication Success Signal Connect the orange line with black stripes authentication success signal of the product to the corresponding input port of the controller With the I O settings the controller...

Page 16: ...eader to the pink line Connect the Wiegand DATA 1 line 1 of the proximity reader to the sky blue line The product should be connected to GND of the external reader For a list of compliant readers external readers see the followings SSA R2010 SSA R2020 SSA R2040 Standard 26bit Wiegand format proximity reader SSA R2011 SSA R2021 SSA R2041 Standard 34bit Wiegand format proximity reader 1 2 3 4 5 CONT...

Page 17: ...tween the product and the host PC Please follow the steps below Connect the yellow RS485 RTX line to the RS485 A port of the converter Connect the gray RS485 RTX line to the RS485 B port of the converter Connect the RS 485 RS 232 converter to the serial port COM port of the host PC Install and launch the application SAMS 1 2 3 4 A B RS 485 RS 232 Con verter RS 232 RS 485 Host PC Max 1200m Gray Yel...

Page 18: ...llow RS 485 A line of other product Connect the gray RS 485 B line of one product to the gray RS 485 B line of other product Set a unique COMM ADDR for each product You must connect one of the RS 485 ports of the product to the RS 485 RS 232 converter Connect the yellow RS 485 A line to the RS 485 A port of the converter Connect the gray RS 485 B line to the RS 485 B port of the converter Connect ...

Page 19: ...n To enable TCP IP communications with the host PC you must have connected the RJ45 jack to CON4 8 PIN connector Please follow the steps below Connect the RJ45 jack of the product to the RJ45 plug of the network system Install and launch the application SAMS 1 2 Hub RJ45 RJ45 RJ45 RJ45 Host PC ...

Page 20: ...s sounding the beep until you change the communication address Use the DIP switch to specify the BOARD ID Refer to Communication Address Setup on page 22 You must specify the communication address and register the master ID If you initialize the hardware system all data settings return to the factory default including IDs fingerprint data master ID card number output format IP If you initialize the...

Page 21: ...the user card PWR OK ERR 3 BEEPS ID REGISTERED The user card is registered successfully PWR OK ERR 3 BEEPS FINGERPRINT REGISTERED The user card fingerprint is registered successfully PWR OK ERR 2 BEEPS FINGERPRINT REGISTRATION FAILED PLEASE TRY AGAIN Failed to register the user card fingerprint PWR OK ERR 4 BEEPS ID DELETED The user card fingerprint is deleted successfully READER MODE LED Beep Voice ...

Page 22: ...S SETUP You can upload or download the user fingerprint using SAMS You can also change the settings of the product to apply to different situations The Board ID is a device address based on which the SW application recognizes the device For this purpose the Board ID should be unique You can specify up to 255 different BOARD IDs from 000 to 254 Use the DIP switch on the rear panel to specify the BOA...

Page 23: ...istered in RF Finger mode Present the registered card to the reader When the card is recognized the red lamp on the scanner turns on Place the registered fingerprint on the scanner When the fingerprint is authenticated successfully you will hear a long beep with the green indicator turned on and the user ID will be displayed according to the specified output format If the fingerprint is denied you wil...

Page 24: ...FINGERPRINT Check if the green and orange indicators are all turned off when the reader turns on Present the master card to the reader You will hear the following voice message with the green and orange indicators blinking Present a user card to the reader Upon the voice message of PUT YOUR FINGER Place the fingerprint on the scanner Upon the voice message of REMOVED FINGER release the fingerprint f...

Page 25: ...ange indicators blinking Present a registered user card to the reader When you hear the following message with a beep four times the user is deleted successfully When the ID is deleted the fingerprint data will be deleted too Repeat step 3 above if you want to delete another user When the ID deletion is completed present the master card to exit the registration mode 1 2 3 4 5 Q REGISTRATION AND DEL...

Page 26: ...26 bit 34 bit Even parity bits from Bit 2 to Bit 13 Bit 2 to Bit 17 Bit 2 to Bit25 Bit 2 to Bit33 3 byte ID number 4 byte ID number Bit 26 Bit 34 Odd parity bits from Bit 14 to Bit 25 Bit 18 to Bit 33 100us 1ms DATA 0 DATA 1 LOGIC 1 0 2 1 3 1 n n 34 or 26 0 n 2 1 n 1 5V 0V 5V 0V 0 ...

Page 27: ...anage fingerprints Follow the instructions below to increase the rate of successful authentication of the fingerprint For a dry fingerprint put force to present the fingerprint to the scanner For a moist fingerprint gently present the fingerprint to the scanner Keep the fingerprint scanner clean all the time especially on the surface Fingerprint scanning Successful 1 1 1 N Authentication Fingerprint Scan...

Page 28: ...ry default card deleted system initialized master card deleted etc 3 If the problem persists contact the nearest customer service for technical help Fingerprint registration or authentication do not work well 1 Please check the correct fingerprint registration instruction in the user manual and try again Proper fingerprint position Improperly positioned fingerprints 2 Check the state of the fingerpr...

Page 29: ...gateway and port number For details on the settings refer to the user manual of the software 2 Check if the communication wiring is done correctly For RS 485 RS 485 Single This product RS 485 RS 232 Converter PC RS 485 A RS 485 A RS 232 cable of the converter RS 485 B RS 485 B RS 485 Multi Drop This product This product RS 485 RS 232 Converter PC RS 485 A RS 485 A RS 485 A RS 232 cable of the conv...

Page 30: ...ion Time Less than 1sec Identification Time Less than 2sec Communication RS232 RS485 TCP IP Baud Rate bps 57 600 Input Port 3 EA External LED Control External Buzzer Control Operating Mode RF RF Finger Control Output Port 2EA Error Output OK Output Open Collector Output 26bit Wiegand 34bit Wiegand LED Indicator 3 LED Indicators Red Green and Orange Beeper Piezo Buzzer Voice Output Language English...

Page 31: ...Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environ...