Page 1: ...Setup Guide PRINTER S INSTRUCTIONS MANUAL QUICK START NOVA SMOKE NORTEK P N 10015711B INK BLACK PLUS PMS 286C MATERIAL 105G COATED PAPER SIZE 105MM X 105MM SCALE 1 1 BINDING TRIM FOLD AND SADDLE STITCHED PAGE 1 OF 34 ...

Page 2: ...w device Make sure you are within 350 feet from the ADT Security Hub Exact range depends on your home s construction the environment the position of the ADT Security Hub and the position and number of other connected devices Make sure that you only setup one new device at a time 3 Do not remove the battery tab until you are ready to set up the detector ...

Page 3: ...hone to select the My Home tab Select Things and then Add a Thing Setup med e on 3 Use the SmartThings app to scan the QR code on the front of the alarm and then follow the on screen instructions to complete setup Smoke Alarm Front QR Code dy ...

Page 4: ...he front of the alarm and attach it inside the ADT Security Hub User Guide for future reference 4 Remove the tab on the smoke alarm marked Pull This Tab The yellow LED will blink once followed by a single blink of the red LED Battery Tab Smoke Alarm Back ...

Page 5: ...l Fire Alarm Code NFPA Standard 72 a smoke alarm should be installed In all sleeping rooms and guest rooms Outside of each separate dwelling unit sleeping area within 21 feet of any door to a sleeping room the distance measured along a path of travel On every level of a dwelling unit including basements nd r y ...

Page 6: ...ULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STANDARD 72 In the living area s of a guest suite In the living area s of a residential board and care occupancy small facility On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics The pro are by t The fin rec exp ope For con are inc...

Page 7: ...nished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation or false alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not ...

Page 8: ...hin 21 feet of the fire to respond quickly Smoke alarms also need to be in positions where they can be heard throughout the property so they can wake you and your family in time for everyone to escape A single smoke alarm will give some protection if it is properly installed but most homes will require two or more to ensure that a reliable early warning is given For recommended protection you shou...

Page 9: ...om the house Single Story Dwellings If the premises is one story you should put your first smoke alarm in a corridor or hallway between the sleeping and living areas Place it as near to the living area as possible but make sure that it can be heard loudly enough in the bedroom to wake someone In houses with more than one sleeping area smoke alarms should be placed between each sleeping area and th...

Page 10: ... ing una suc This Placement Multiple Story Dwellings If your home has more than one floor at least one smoke alarm should be fitted on each level Suggested locations shown below Attic Bedroom Kitchen Basement Garage MasterBedroom FamilyRoom Hallway ...

Page 11: ...m Consideration should be given to installing smoke alarms in any bedrooms where fires might occur for instance where there is an electrical appliance such as an electric blanket or heater orwhere the occupant is a smoker In addition consideration should be also given to install ing smoke alarms in any rooms where the occupant is unable to respond very well to a fire starting in that room such as ...

Page 12: ...ot move in corners therefore smoke alarms must be mounted away from corners Keep at least 12 inches from walls and corners Additionally mount the unit at least 12 inches from any light fitting or decorative object which might prevent smoke entering the smoke alarm Do not attach the detector to removable ceiling panels 4 Inches 10cm 3 Feet 0 9m 3 Feet 0 9m Not this area Anywhere in this area ...

Page 13: ...similar obstructions may preclude ceiling mounting It is considered to be the responsibility of the installer or homeowner to determine if the presence of asbestos in the ceiling material would make ceiling mounting impractical The top of the detection element is between 6 inches and 12 inches below the ceiling The bottom of the detection element is above the level of any door openings Placement v...

Page 14: ...this position On a sloping or peaked ceiling install a smoke alarm within 24 inches of the peak measured vertically If this height is less than 24 inches the ceiling is regarded as being flat Placement Smoke Alarm front Wall behind alarm ...

Page 15: ...Install the mounting base using the two screws and anchors provided 1 C Mounting Mounting Plate Smoke Alarm 12 inches from wall 12 inches from wall is t Ceiling Mount ...

Page 16: ...2 3 Pu Mounting Wall Mount 12 inches from ceiling 12 inches from wall Smoke Alarm Mounting Plate ...

Page 17: ...er the base then turn the alarm in a clockwise direction until it clicks into place 2 Test the alarm after completing the installation see following section for details 3 Mounting Plate Alignment Marks Push Up And Turn Clockwise Smoke Alarm Mounting ...

Page 18: ...they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue would be necessary WARNING please read carefully and thoroughly Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insurance policy Homeowners and renters should hav...

Page 19: ...owered alarm must have a battery of the specified type in good condition and installed properly Studies have shown that smoke and heat alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or those who may be incapable of safely e...

Page 20: ...itions with a focus on rapid exit from the residence are important Drills should be held so that all family members know the action to be taken The use of alcohol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Smoke alarms must be tested regularly to make sure the batteries and t...

Page 21: ...ut of every room if possible Make sure all doors and windows leading outside open easily Practice using different ways out Safety Tips If the alarm is located outside the sleeping room or on a different floor it may not wake up a sound sleeper Practice your home fire drill at night and during the day with everyone in your home twice a year Mounting ...

Page 22: ...eir own in case you can t help them Close doors behind you as you leave Have an outside meeting place like a tree light pole or mailbox a safe distance from the home where everyone should meet Tes a w pla ADT D Mounting Not acti con in t ...

Page 23: ...ts place your ADT Security Hub in Walk Test Mode See the ADT Security Hub User Guide for more details D Testing Note If you have an ADT professional monitoring service activated additional testing is required wheneveryou connect a new device Follow the on screen instructions in the SmartThings app to complete testing ...

Page 24: ...about 12 inches from the alarm to avoid damaging the plastic The alarm will reset once it cools down Sm smo blo Alarm Operation Test Push and hold the Test button on the alarm for a minimum of five seconds The alarm will sound and the red LED blink The ADT Security Hub will display an alert for the smoke alarm Flashing Red LED Press And Hold Until Alarm Sounds ...

Page 25: ...larm To clean your alarm remove it from the mounting base You can clean the interior by using a vacuum cleaner hose to blow orvacuum through the openings The outside can be wiped with a dry cloth After cleaning reinstall and test your alarm as described above YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR hes m Smoke Test Hold a match canned smoke or other smoldering stick near the alarm with c...

Page 26: ...the reset button twice Press and hold the button for 5 seconds until the red LED starts blinking quickly If the alarm did not pair successfully with the ADT Security Hub follow these instructions to reset it If yo Ala ass 1 2 3 4 5 6 Troubleshooting Reset Button ...

Page 27: ... please visit SmartThings com Support ADT for assistance 4 5 6 Continue to press and hold the button until the red LED turns solid Release the button and after 5 seconds the red LED will begin to blink slowly Use the SmartThings app to complete setup Troubleshooting ...

Page 28: ...ED flash every 8 seconds Smoke alarm hushed Batteries low Smoke and or heat sensor error Product expired 10 years typical life 1 beep plus yellow LED flash every 48 seconds 2 beeps plus yellow LED flash every 48 seconds 3 beeps plus yellow LED flash every 48 seconds Use If sa imm Wh No a Rep Rep Rep ...

Page 29: ...rce of the smoke If unknown get out of the house immediately Follow appropriate fire safety guidelines at all times What To Do Use No action required Replace batteries Replace unit with same brand Replace unit with same brand ...

Page 30: ...DT Security Hub There are many ways you can use an ADT Smoke Alarm in your home Put one in your living room and set it to initiate optional ADT professional monitoring service when smoke is detected in your home additional fees apply Visi spe Not dev des pro Your ADT Security Hub can then send an alert to your smartphone automate connected devices or initiate optional ADT professional monitoring s...

Page 31: ... fire is detected Suggestions Put one in your home and set a connected camera to record video when smoke is detected additional fees may apply Visit SmartThings com Welcome for more ideas tips and special offers Note To ensure proper functioning all connected devices must be configured correctly This alarm is not designed to be interconnected with other manufacturers products unless otherwise spec...

Page 32: ...SmartThings com to see the full list of compatible devices Works With SmartThings H SmartThings works with a wide range of connected devices including lights cameras locks thermostats and sensors It also works with the Google Assistant and Amazon Alexa so you can control your smart home with voice commands ...

Page 33: ...t e ...

Page 34: ...in View CA 94043 USA Information in this document is subject to change without notice Copyright 2017 SmartThings Inc All rights reserved ADT and the ADT logo are marks and or registered marks of ADT Unauthorized use is strictly prohibited Revised 06 17 ...