background image

GC68-00349B  ED:01

SEOUL COMMTECH CO., LTD.

448-11, Seongnea3dong, Kangdong-Ku, Seoul, Korea
Post Code : 133-034 

Phone : +82-2-2225-6709 

Fax : +82-2-2225-6073 

Homepage : www.scommtech.co.kr

The safety precautions contained herein are served to protect the user and prevent material loss.  
Please make sure to read this manual carefully to ensure proper product usage.

Intelligent Digital Door Lock   

EZOn

SHS-DS10

Manual

Summary of Contents for EZON SHS-DS10

Page 1: ... 034 Phone 82 2 2225 6709 Fax 82 2 2225 6073 Homepage www scommtech co kr The safety precautions contained herein are served to protect the user and prevent material loss Please make sure to read this manual carefully to ensure proper product usage Intelligent Digital Door Lock EZOn SHS DS10 Manual ...

Page 2: ...se Initialization Password Card Key Tag 14 Registration Modification Deletion Password 15 Key Tag Card 16 Usage Password 18 Key Tag Card 19 Automatic Manual Lock Usage 20 Sound Programming Cancellation 21 Alarm Emergency Sounds 22 Dual Lock Usage 24 Opening the Door from the Inside 25 Battery Usage 26 Usage Summary 28 Usage Precautions 32 Troubleshooting 33 ...

Page 3: ...e sure to prevent water from entering the product Water penetration can result in product damage and or malfunction Do not use pins or any sharp pointy objects to press buttons or insert into holes Doing so can result in product damage and or malfunction When cleaning do not use wet cloths or volatile substances such as alcohol benzene thinner etc Doing so can result in product damage and or malfu...

Page 4: ... a safety inspection following any repair can result in injury upon operation When moving make sure to pass on this manual To help the new resident passing on this manual can prevent incorrect usage Product Installation 1 Assembly Diagram Reference to the installation sheet provides information that may facilitate more careful and precise installation Exterior Rubber Pad Interior Rubber Pad Fixed ...

Page 5: ...echnician Self installation or disassemble qualifies as customer negligence 2 When moving please contact the sales agent from where the product was purchased or the customer service center 2 Notes for Product Installation Product Setup 1 Main Unit Exterior Unit Exterior Rubber Pad Interior Unit Interior Rubber Pad Fixed Panel ...

Page 6: ...ring card recognition or operation this lamp turns blue Keypad Protection Cover This cover protects the keypad Keypad You can use this to register modify delete your password Inputting the registered password releases the lock Card Recognition Device and Button After pressing the button placing a registered card or key tag against the recognition device or inputting the password releases the lock ...

Page 7: ...ds or cards OPEN Button This one touch button is used from the inside to lock unlock the door Emergency Open Close Lever This button can be used in emergencies or when circuits are not functioning to manually lock unlock the door from the inside left right locked middle unlocked Dual Lock Lever Dual lock activation makes it impossible to release the lock both in outside Deadbolt The deadbolt faste...

Page 8: ... time the default password is 1234 Beep Beep Beep Beep Beep Beep Input the new password for registration and then press the star button Beep Beep To complete registration input the new password once again and then press the star button Beep Beep Beep Beep Initialization Password Card Key Tag 1 Password Known Press the star button Beep Beep Beep Beep 2 Password Unknown Open the battery cover in the...

Page 9: ...ce the next card s on the card recognition device within five seconds To confirm card registration carry an emergency key open the door make sure the deadbolt is extended and follow directions on card usage Follow the process outlined above to register additional card s at any time CAUTION Open the battery cover in the interior unit and press the registration button once Beep After inputting the p...

Page 10: ...ively results in the sounding of a warning signal for ten seconds and the unit shuts down for one minute During shutdown a beep sound will be emitted every ten seconds The system returns to normal if a registered card is recognized or after a series of beeps signals the end of one minute If you make a mistake when inputting the password and would like to cancel press the sharp button Executing thi...

Page 11: ...on Beep Beep Beep Beep Automatic Manual Lock Confirmation Method With the door open if the deadbolt automatically extends after pressing the door ajar sensor the automatic lock is engaged When the door is closed and the lock has been released via password card remote control etc if the handle is not turned and the door opened within seven seconds the door lock automatically engages again If automa...

Page 12: ...om the inside attempting to disengage the lock by using the OPEN button or the Emergency Open Close Lever will produce an emergency sound intrusion detection using the OPEN button 1 Activation From the inside press the registration button on the interior unit or extract the batteries to deactivate the crime prevention mode From the outside opening the door by entering a registered password or usin...

Page 13: ...Beep Beep Beep Beep Beep 1 Dual Lock Activation When the door is closed turn the dual lock lever so as the red background is fully visible 2 Dual Lock Deactivation Turn the dual lock lever so as the green background is fully visible Opening the Door from the Inside Dual Lock Activated 1 Electronic Method When the door is locked pressing the OPEN button on the interior unit releases the lock Pressi...

Page 14: ...ord or card In such cases a 9V 6LF22 battery can be placed on the external power contacts to restore temporary operational power The emergency battery must be 9V External Power Supply Replacement intervals may vary according to varying battery manufacturers manufactured dates and usage environments CAUTION Make sure to use alkaline batteries Do not use regular manganese or rechargeable batteries D...

Page 15: ...ration Button Once Beep Enter the Registered Password 4 12 Digits Press the Star Button Beep Beep 2 Usage Press the Key Tag Recognition Button Key Tag Recognition Beep Beep Beep Beep Place Key Tag on Recognition Device Enter the code 4560852580 Press the Registration Button for Ten Seconds Beep Beep Beep Beep Beep Beep Beep Enter the Registered Password 4 12 Digits Press the Registration Button fo...

Page 16: ...Miscellaneous ...

Page 17: ...assword modification process referring carefully to the manual The automatic lock function does not work Check to see if the auto manu switch is set to automatic Open the door If the deadbolt automatically extends after pressing the door ajar sensor the function is operational Any malfunction is due to an installation defect and the installation center should be contacted Check to see if the batte...

Page 18: ...se of accident misuse damage caused by improper installation and altered serial numbers 3 If you need a warranty service you should send the product to customer Dep t or dealer office the product in all cases must be accompanied by the following items Customer name address telephone number the serial numbers copy of customer sales receipt showing the purchase date and place The Model number is on ...

Reviews: