Summary of Contents for Ezon SHS-5120EM series

Page 1: ...1 ...

Page 2: ......

Page 3: ... be locked manually Using the automatic lock function the door is automatically locked when it closes eliminating the need to lock it manually Double locking function adds security The double locking function adds security by preventing the door from being opened from outside at night or at times when extra security is needed Pranks played by children and juveniles can be prevented When an unregis...

Page 4: ...Basic Functions 17 Initialization Password Card Key Tag and Remote Controller 17 Password Registration and Change 18 Card and Key Tag Registration 20 Deleting the Card or Key Tag 22 Remote Controller Registration 23 Deleting the Remote Controller 25 Wireless HA Device Registration and Deletion 26 Opening the Door from Outside with a Password 27 Opening the Door from Outside with a Card or Key Tag ...

Page 5: ...ditional Functions 32 Automatic Manual Locking Setting 32 Sound Setting and Releasing 33 Alarm Sound Emergency Sound 34 Troubleshooting 38 Operating Method Summary 40 Product Specifications 42 W ARRENTY 43 ...

Page 6: ...ing Information given under this heading is information the user must be aware of to prevent physical harm Caution Information given under this heading is information the user must be aware of to prevent service problems or system damage Note Information given under this heading provides additional information relating to the text in this manual Description of Symbols General warning or caution Pr...

Page 7: ...place where the gap between the door and the frame is 5mm or more If the gap is too wide the product may not function properly Make sure that no unauthorized person has the access to the password To minimize the risk of burglary it is recommended that you periodically change the password Do not operate the product with wet hands and keep liquids such as water or drinks away from the product or the...

Page 8: ...zene or alcohol when cleaning the product as these fluids can cause product malfunction Use a soft and dry cloth instead Replace the batteries within 1 week after the battery replacement alarm sounds The product can stop operating if the batteries are not replaced in time Be careful not to trap fingers while opening or closing the number cover There is a risk of fingers being trapped in the gap Be...

Page 9: ...of the SHS 5120 series No Model Emergency Key Pass word Key Tag Card Remote Controller Interface to Wireless HA Devices One way Interface to Wireless HA Devices Two way 1 SHS 5120XMX Ⅹ Ⅹ Ⅹ 2 SHS 5120RMX Ⅹ Ⅹ 3 SHS 5120REX Ⅹ Ⅹ 4 SHS 5120EMX Ⅹ Ⅹ 5 SHS 5120VMX Ⅹ Ⅹ Ⅹ Ⅹ The last letter X in each model indicates color code ...

Page 10: ...8 Product Components Mortise User Guide Strike AA Batteries LR6 Outdoor Unit Strike Box Indoor Unit Emergency Key Except for SHS 5120VMX model Key Tag ...

Page 11: ... Panel and Indoor Unit Fastening Bolts FH M4 8 4EA Support Panel and Outdoor Unit Fastening Bolts OH M5 25 TH M5 20 2EA Indoor Fastening Bolts PW 8 16 4EA Strike Fastening Bolts FH U10 24 10 4EA Handle Shaft Spring The product components used may vary depending on the installation environment ...

Page 12: ...utdoor Unit Parts Number Pad Unlighted Outdoor Unit Handle Card Reader Number Pad Enter Number Button and Running LED External Power Contact Emergency Keyhole Except for SHS 5120VMX model Number Pad Lighted ...

Page 13: ...opening the door 4 Outdoor Unit Handle The door will be opened when the handle is rotated downward after the lock is released 5 Emergency Keyhole Except for SHS 5120VMX model When the lock stops operating because of batteries that have been completely discharged or a circuit problem the emergency key can be used to unlock the door After that the door will be opened when the outdoor unit handle is ...

Page 14: ...12 Indoor Unit Parts Password Button Automatic Manual Locking Toggle Switch Indoor Unit Handle Remote Controller Button Open Close Button Registration Button Manual Open Close Lever Battery Cover ...

Page 15: ... register or delete the wireless remote controller 5 Password Button This button is used to change the password 6 Open Close Button This button is used to lock the door from the inside and to set the double locking function 7 Manual Open Close Lever This is used to lock or unlock the door manually in an emergency or when the circuit is out of order 8 Indoor Unit Handle The door will be opened when...

Page 16: ...teries are not replaced Although actual battery life differs depending on the manufacturer date of production and operation environment eight 1 5V AA alkaline batteries can last for one year based on an average of 10 uses per day Battery Life Warning tune 8 AA batteries If the poles of the batteries are not placed properly the door lock will not operate normally Liquid leaks from batteries can dam...

Page 17: ...attery Buy an emergency battery 9V at the nearest store 3 Opening the Door Using the Emergency Battery Place the card or key tag on the card reader or enter the password while the 9V battery is connected to the external power contact of the outdoor unit Or Recognition of Card or Key Tag Or Password Entry The door is not opened As the alkaline batteries offer longer life they are recommended over t...

Page 18: ...ey into the keyhole and rotate it to the left and to the right to release the door lock Always carry one or more emergency keys or store one in a secret place outside If the emergency key is lost it is recommended to replace the whole key cylinder unit Contact your local dealer Replacement of the key cylinder unit is not a free service Remove the emergency key from the keyhole after the door lock ...

Page 19: ...ed 1 Opening the Cover from inside Lightly press the battery cover and push it up as shown in the diagram 2 Pressing the Password Button from inside Press and hold the Password button for 5 seconds or longer Successful TootÆToot toot sounds are generated 3 Entering the Password from outside Press the registered password or 4560852580 then press the button Successful Too t sound is generated Failed...

Page 20: ...Pressing the Password button from inside Open the battery cover of the indoor unit and briefly press the Password button 2 Entering the Current Password from outside Enter the current password 12345 after initialization when the number pad is lighted and press the button Too t toot toot Toot Always hold the door open while registering or changing the password Open ...

Page 21: ...ck the new password and close the door Please refer to Opening from Outside with a Password on page 27 Too t Too t To check the new password press the door opening sensor on the Mortise while the door is open When the dead bolt is pushed out check the password referring to the procedure described in Opening from Outside with a Password Manage your password with care so that unauthorized people wil...

Page 22: ...Register button 2 Entering the Password from outside Enter the password when the number pad is lighted and press the button 3 Placing the Card or Key Tag in Contact from outside Place the card or key tag to be registered on the card reader of the outdoor unit You will know the card or key tag has been registered when a long too t sounds Too t toot toot Toot Too t Registering a card or key tag is a...

Page 23: ...itional card or key tag after the registration process is terminated repeat the registration process with the card or key tag To register multiple cards or key tags lightly place another card or key tag to the card reader within 5 seconds of registering the previous card or key tag If another card or key tag is not exposed to the card reader within 5 seconds of registering the previous card or key...

Page 24: ...essful Too t sound is generated Failed Toot sound is generated TootÆToot toot Registered cards cannot be individually deleted All card information is deleted when the card delete function is selected Previously registered cards cannot be used to open the locked door after they are deleted Register a new card after deleting the card data To open the locked door from outside after deleting card data...

Page 25: ...e Password from outside Enter the password when the number pad is lighted and press the button 3 Pressing the OPEN Button from the remote controller Press and hold the OPEN button of the remote controller to be registered for 3 seconds or longer Too t toot toot Too t Toot Repeat the process above when registering an additional remote controller Registering a remote controller is available while th...

Page 26: ...Registration from outside In Automatic Locking Mode Briefly press the OPEN button on the remote controller In Manual Locking Mode When the OPEN button on the remote controller is pressed the door will be locked or the lock will be released ...

Page 27: ... toot Registered remote controllers cannot be individually deleted All remote controller information is deleted when the remote controller delete function is selected A previously registered remote controller cannot be used to open the locked door after it has been deleted Register a new remote controller after deleting the remote controller data To open the locked door from outside after deleting...

Page 28: ... or higher are compatible with the door lock Please call your local dealer to register or delete the registered wireless HA device Refer to the operating manual of the wireless HA device to open the door using the device When a wireless HA device is registered only one remote controller can be registered ...

Page 29: ...ted If the light is turned off press the Enter Number button and reenter the password If the wrong password is entered press the button to cancel the entry and start from the beginning If the wrong password is entered 3 times in a row a toot toot toot alarm will sound for 10 seconds and the door lock will stop operating for 1 minute While the door is in this inactive mode a single toot sound is ge...

Page 30: ...d after 1 second Place the card or key tag on the card reader Successful Too t sound is generated Failed Toot sound is generated The card reader will operate properly when the card and key tag is placed within 30mm and 20mm of the card reader respectively The recognition distance may differ depending on the card manufacturer A Toot alarm sound is generated when an unregistered card is placed or th...

Page 31: ...nit Pulling down the Door Lock Handle Rotate the door lock handle of the indoor unit downward Rotating the Manual Open Close Lever Right and Left Rotate the Manual Open Close lever on the indoor unit to the right or left to lock or unlock the door This function can operate without any batteries Too t Too t ...

Page 32: ...ked or unlocked each time the OPEN button of the remote controller is pressed in the manual locking mode Pressing the Open Door Button of a Wireless HA Device The door is unlocked when the Open Door button of the wireless HA device is pressed This function may differ depending on the model of the wireless HA device ...

Page 33: ...nit when the door has been opened from inside in manual locking mode Closing the Door from Inside In Automatic Locking Mode In Manual Locking Mode The door is automatically locked 2 seconds after closing the door The door is locked when the Open Close button or the OPEN button of the remote controller is pressed ...

Page 34: ...he indoor unit the OPEN button of the remote controller or the Enter Number button of the outdoor unit is pressed Difference between Automatic and Manual Modes For security reasons ensure that the door is locked after locking the door in the manual locking mode since it is not automatically locked after being closed The door lock is set for the automatic locking mode if the deadbolt is automatical...

Page 35: ...the Password button on the indoor unit Toot 0 Button All sounds except the alarm sound are deactivated 1 3 Button All sounds are activated and the sound gets louder as the step goes up The sound function is set in two steps after initialization In registration mode sound is generated regardless of the current setting The setting is in effect when registration is completed Setting and releasing sou...

Page 36: ...alarm will sound if an attempt is made to open the door with an invalid card or if a wrong password is entered three times in a row The alarm sound is generated and the door lock is deactivated for 1 minute While the door is in this inactive mode a single toot sound is generated every 10 seconds and seven consecutive toots will sound after 1 minute Following this the lock is released from inactive...

Page 37: ... Close button or by turning the door lock handle of the indoor unit Expose the registered card or key tag to the card reader or enter the password and then press the button The security function is automatically released when the locked door is opened from outside by entering the registered password or exposing the card or key tag to the card reader Press the Enter Number button on the outdoor uni...

Page 38: ... toot toot for 5 minutes Open the battery cover of the indoor unit and take out the batteries or press one of the registration buttons or the OPEN button of the remote controller Expose the registered card or key tag to the card reader or enter the password and then press the button Inside Outside The fire detection function is activated when the temperature rises around 55 sensor operating temper...

Page 39: ...he Enter Number button is pressed or a card is applied Inside Outside Too t too t Press the Open Close button for 2 seconds or longer from the inside while the door is locked Too t The double locking function is released when the indoor unit handle is rotated downward or the manual Open Close lever is rotated to the right or left Inside Too t too t Please be cautious when using this function since...

Page 40: ...er guide P 18 19 The card or key tag cannot be registered When registering multiple cards and key tags continuously the next card or key tag must be placed on the card reader within 5 seconds of the previous card or key tag P 20 21 The door cannot be opened even after entering the password followed by the button Check that the registered password has been correctly entered If the light of the numb...

Page 41: ...de has been set If the operation mode is set to the manual locking mode press the Enter Number button to lock the door If the door does not automatically lock when in the automatic locking mode then the door lock is installed improperly Contact the digital door lock installer to have it reinstalled The automatic locking function will not work if the batteries are completely discharged Check the ba...

Page 42: ...n Card and Key Tag Delete None Press and hold the Register button for 5 seconds Password entry button Remote Controller Registration None Remote button Password entry button Press and hold the OPEN button of the remote controller for 3 seconds Remote Controller Delete None Press and hold the Remote button for 5 seconds Password entry button Wireless HA Device Registration and Deletion None Please ...

Page 43: ...c Locking Place the Automatic Manual Locking toggle switch in the Manual position Sound Setting Releasing 2 Setting Press and hold the Password button Press or button Security Function Setting Press the Enter Number button while the door is locked Press and hold the button for 3 seconds Enter the password button Security Function Release Enter the password or place the card or key tag Emergency So...

Page 44: ...r Unit including the handle 82 mm W 299mm H 65 5 mm D Indoor Unit including the handle 78 mm W 318 mm H 78 mm D Product Dimensions Key Tag 23 5 mm W 54 mm H 6 mm D The content of this manual is subject to change without prior notice to the user in order to enhance performance of the product Product Name Model Name Wireless device using extremely low power radio SHS 5120 Certificate Number SCT SHS ...