background image

ASSY Wi-Fi Kit 2.0

CONTENTS

ASSY Wi-Fi Kit 2.0

Model Name :    MIM-H04EN 

MIM-H04RN 

MIM-H04N 

MIM-H04UN 

MIM-H04NDZ

1. Wi-Fi Kit 2.0 Installation

2. Troubleshooting

MIM-H04EN

MIM-H04RN

MIM-H04N

MIM-H04UN

MIM-H04NDZ

Summary of Contents for ASSY MIM-H04EN

Page 1: ...ASSYWi Fi Kit 2 0 CONTENTS ASSYWi FiKit2 0 Model Name MIM H04EN MIM H04RN MIM H04N MIM H04UN MIM H04NDZ 1 Wi Fi Kit 2 0 Installation 2 Troubleshooting MIM H04EN MIM H04RN MIM H04N MIM H04UN MIM H04NDZ ...

Page 2: ...Samsung Electronics 1 Contents 1 Wi Fi Kit 2 0 Installation 1 1 2 Troubleshooting 2 1 ...

Page 3: ...wiring Installation on the wall Installation in the wall CAUTION To ensure smooth operation there should be no obstacle between the Wi Fi Kit and wireless router that may interfere with communication When the Wi Fi Kit is too far from a router or there are potentially interfering elements between them it may cause problems with the performance of the Wi Fi Kit that cannot be resolved by customer s...

Page 4: ...p to 16 indoor units to a Wi Fi Kit 참 고 Ռ Վ Ս Ս Ǥ Ռ Ǥ Տ ⓑ ⓔ ⓕ ཿ ⓓ ⓒ 10 0 4 and over 10 0 4 and over 50 2 and over 10 0 4 and over Screw holes V1V2 F1 F2 Wi Fi Kit PCB port Indoorunit Unit mm inch Back over Be sure to secure space of at least 10 0 4 inch mm up right left and 50 2 inch mm down around the back cover before fixing the back cover on the wall Fix the screws to the screw holes Do not ove...

Page 5: ...ltiple units Connection between the Wi Fi Kit and a single unit Connecting between the Wi Fi Kit and ERV devices Wi Fi Kit wiring diagram 5 Assemble the Wi Fi Kit again 참 고 Insert the front cover to the upper grooves as shown in the figure After assembly make sure that there is no gap between the covers NOTE ...

Page 6: ...R1 R2 F2 F1 F1 F2 V1 V2 F1 F2 Touch centralized controller DMS CAUTION You can connect up to 16 indoor and outdoor units Connect R1 and R2 on the outdoor unit to F1 and F2 of the Wi Fi Kit Connect the power cables to V1 and V2 of the indoor unit Other controllers e g touch centralized controller DMS can be installed together ...

Page 7: ... to V1 and V2 of the the indoor unit or ERV Other controllers e g touch centralized controller DMS can be installed together 3 Connecting the Wi Fi Kit and the ERV together R1 R2 AĘՏ AĘՎ ŵkU AĘՍ 9øç F1 F1 F1 F1 F1 V1 F1 F2 F2 F2 F2 F2 V2 F2 R1 R2 R1 R2 V1 V2 F1 F2 V1 V1 V2 V2 Touch centralized controller DMS MIM N10 ...

Page 8: ... F2 V2 V2 BLK F2 R1 R2 k ʒ Ǯ Ս ʒ ϩ ø Cablerange Rated size Stud size Defaultsize mm inch AWG mm mm mm inch2 inch2 inch t d E F W L 24 16 0 25 1 65 1 5 3 3 2 0 6 0 8 1 2 2 5 4 6 5 9 5 7 12 21 2 Max length forcommunication powercables 50 m 164 ft 0 0003 0 0025 0 1181 0 1259 0 0236 0 0314 0 0472 0 0984 0 1574 0 2362 0 1968 0 3543 0 1968 0 2755 0 4724 0 8346 0 0023 Fasten the PCB terminal with fixing ...

Page 9: ... kit is turned on the tracking is performed automatically During the tracking the lamp of the Wi Fi kit blinks If the tracking is completed but the lamp blinks it means the Wi Fi kit does not find connected indoor units In this case check whether the connection of communication cable between indoor unit and outdoor unit is correct or is a ected by noise If the configuration of indoor unit or outdoor...

Page 10: ...mode On Off On 7 Tracking units Blinking Blinking Off 8 No unit tracked Blinking Off Off 9 Inspection of the network PBA required On Blinking Blinking 10 User authentication required AP mode On Off Blinking 11 Downloading Off On Off 12 Rescue mode Blinking On Blinking If you see Rescue mode LED when you service Please press AP button for 5 seconds Then Wi Fi Kit will be do Factory Reset After Fact...

Page 11: ...e of the Wi Fi Kit 4 The indicator ⓓ on the Wi Fi Kit blinks every 2 seconds during update Once the update has been successful the indicator promptly turns on and then turns off longer On 0 2 second Off 2 seconds The indicator blinks every 0 2 second when the update is completed abnormally 5 When the update is completed normally remove the Micro SD card and then press the Reset button 6 Restarting...

Page 12: ... 2015 02 27 오후 4 09 22 7 t G F L AWG mm 2 mm2 mm t ΦD G E F W L 22 16 0 25 1 65 1 5 3 0 7 3 8 10 0 4 5 6 5 6 0 21 2 m wiring length for communication and power 50 m 164 feet xing screws to the PCB terminal with less than 6Nm torque When the screws are tightened with more que the screw thread will be damaged is turned on all the lamps are turned on until system operates perates tracking is performe...

Page 13: ...ilable for each indoor unit 1 To select a mode other than the current operation mode turn off the indoor unit to display all operation modes to select 2 When there is a master indoor unit change the operation mode of the master unit The LED indicator remains in its initial state The LED state changes within 1 minute 1 Check the connection cable between the network PBA and the Interface module PBA ...

Page 14: ...any routers around that cause frequency interference More the duplication of the Wi Fi channels between the router to be installed and the ones around more the possibility of the occurrence of communication problems Start Wi Fi Analyzer see if there is a frequency interference by comparing the channels with the routers around and set the channel as the most far separated one OTHERS Check the frequ...

Page 15: ...Replace the PCB if the problem is still same even thoughconnection is exactly correct OTHERS Item LED indication Power supply Wi Fi connection Wi Fi setting 1 Initialized On On On 2 General On On Off 3 AP connected Internet connection incomplete On Blinking Off 4 Tracking completed AP connection incomplete On Off Off 5 Wi Fi modem malfunctioning Blinking Blinking Blinking 6 Searching AP AP mode On...

Page 16: ... F2 line This F1 F2 line supports the non polor I ndoor installation information isdifferent from the actualinstallation Press the tracking button for one second to performthe tracking again OTHERS Item Contents Item Contents Ⓐ Power communication terminals Ⓓ LED Ⓑ Tracking Reset button Ⓔ Network PBA Ⓒ Micro SD card slot Ⓕ Interface module PBA Wi Fi kit 2 3 Wi Fi Kit 2 0 function ...

Page 17: ... communication is not connecting between Wi Fi Kit 2 0 and Router When router does not support SSDP Protocol 1 I nstall the Wi Fi Kit 2 0 in a place close to the router 2 Update the firmware of router with the latest version OTHERS Check the frequency of channels Start Wi Fi Analyzer app Downloaded from app store 2 3 Wi Fi Kit 2 0 function ...

Page 18: ...nly the operating mode onoutdoorunit in order to prevent the mixed control phenomenon that error occurs because cooling heating mode is designated differently in each of the indoor units 1 If you turn off the other indoor unit when you want to select the current working operation mode andthe other operation mode all operable modes are displayed 2 If the master indoor unit is set up change the oper...

Page 19: ...o Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law K Zone http 20 8 111 9 GSPN GLOBALSERVICE PARTNER NETWORK Area Web Site Europe CIS Mideast Africa gspn1 samsungcspotal com Asia gspn2 samsungcspotal com North Latin America gspn3 samsungcspotal com China china samsungcspotal com ...