background image

IMPORTANT NOTICE:

 Please read this manual carefully before installing or operating your wired remote 

controller. Make sure to save this manual for future reference.

Installation &

Owner’s Manual

WIRED REMOTE CONTROLLER

MODEL

TST-MLD-I-WP24

Compatible with:
• RB, CB, UB, FB Fan Coil Units
• RYB, UYB, CYB, FYB Split Systems

Summary of Contents for TST-MLD-I-WP24

Page 1: ...fore installing or operating your wired remote controller Make sure to save this manual for future reference Installation Owner s Manual WIRED REMOTE CONTROLLER MODEL TST MLD I WP24 Compatible with RB CB UB FB Fan Coil Units RYB UYB CYB FYB Split Systems ...

Page 2: ...rvice of the wired controller please read this manual carefully before using the unit For convenience of future reference keep this manual after reading it All the pictures in this manual are for explanation purpose only There may be slightly different from the wired remote controller you purchased depend on model The actual shape shall prevail ...

Page 3: ...oller 6 Name on the LCD of the wired controller 7 Name of button on the wired controller 8 Preparatory operation 9 Operation 10 Timer functions 11 Weekly Timer 1 12 Weekly Timer 2 13 Fault alarm handing 14 Technical indication and requirement 15 Queries and settings 1 2 4 9 10 11 12 13 14 20 23 29 36 36 37 Table of Contents ...

Page 4: ...allation manual Imporper installation may lead to electric shock or fire Reinstallation must be performed by professionals NOTE Do not install the unit in a place vulnerable to leakage of flammable gases Once flammable gases are leaked and left around the wire controller fire may occure Do not operate with wet hands or let water enter the wire controller Otherwise electric shock may occur The wiri...

Page 5: ...on Preparation before installation 1 Please confirm that all the following parts you have been supply 3 4 5 3 2 M3 9X25 For Mounting on the Wall M4X25 For Mounting on switch box 6 7 8 3 2 No Name Qty Remarks For Mounting on the Wall Plastic screw bars Screws Wall plugs For fixing on switch box Optional Screws 2 Installation and owner s manual 1 1 Wire controller 1 Battery The connective wires grou...

Page 6: ...e cable of high voltage above like 115V 220V 380V and don t wire this kind of wire in the said loop wiring clearance between configured tubes should be at the range of 300 500mm or above 3 The Shielded wire of the wired controller must be grounded firmly 4 Upon finish the wire controller connection do not employed tramegger to detect the insulation 2 Prepare the following assemblies on the site 1 ...

Page 7: ...ve the upper part of wired controller Insert a slot screwdriver into the slots in the lower part of the wired controller 2 places and remove the upper part of the wire controller Fig 3 2 19mm 84mm 46mm 60mm 44mm 120mm 120mm 20mm Buckling position Back cover Straight head screwdriver Front cover ...

Page 8: ...ack cover on the 86 switch box and use one M3 9X25 screw to fix to the wall 3 Fasten the back plate of the wired controller Back plate Screws M4 20 Screw hole fixed on the wall useone φ3 9X25mm Screw hole installed on 86 switch box use two M3 9X25mm NOTE The PCB is mounted in the upper part of the wired controller Be careful not to damage the board with the slot screwdriver ...

Page 9: ...corrected on the first time operation Batteries in the wire controller can time under power failure which ensure the time keep right When the power restores if the time displayed is not correct it means the battery is dead and replace the battery Fig 3 5 4 Battery installation NOTE Put on a flat surface Be careful not to distort the back plate of the wire controller by overtightening the mounting ...

Page 10: ... unit Fig 3 7 Putty Putty Putty Trap Trap Trap 1 indoor unit 2 notch the part for the wiring to pass through with nippers etc NOTE DO NOT allow water to enter the remote control Use the trap and putty to seal the wires 44mm 60mm Wiring hole switch box A B ...

Page 11: ...ct the other side of the connecting cable to the remote control NOTE Be sure to reserve a length of the connecting wire for periodic maintenance If there is a connection lug at the end of shielded wire the connection lug should be properly grounded 4 core wire The connective wires group Front grille shielded wire some units Fig 3 8 Magnetic ring ...

Page 12: ...ing installation Fig 3 9 Wiring specifications Wiring type Size Total length shielded vinyl cord or cable 0 5 1 25mm 50m 164 2 All the pictures in this manual are for explanation purpose only Your wire controller may be slightly different The actual shape shall prevail KJR 120X1 TFBG E DC 5V KJR 120X2 TFBG E DC 12V 5 43 23 110 RH40 RH90 Input voltage Ambient temperature Ambient humidity ...

Page 13: ...venient to place the wires and install the device Room temperature display Weekly Timer Function Mode choose Auto Cool Dry Heat Fan Fan speed Auto Low Med High speed Swing on some models Timer ON OFF Temp setting Weekly timer Follow me Turbo 24 hour System 12 hour System Auto restart Individual louver control on some models Automatic airflow test Child Lock LCD display Clock Panel function on some...

Page 14: ...rature display 4 Lock indication 5 C F indication 6 Main unit and secondary unit indication 7 Turbo function indication 1 2 3 4 5 7 8 9 10 11 12 13 8 Room temperature indication 9 Follow Me function indication 10 Left right swing indication some models 11 Clock display 12 On Off timer 13 Timer display 6 ...

Page 15: ...n the wired controller 1 POWER button 2 MODE button 3 DAY OFF DEL button 4 ADJUST button 5 CONFIRM button 6 TIMER button 7 FAN SPEED button 8 BACK bottom 9 SWING bottom 10 FUNC button 11 COPY button 3 1 2 10 7 9 4 5 6 11 8 ...

Page 16: ...g button in 10 seconds The setting is done after pressing CONFIRM button or there is no pressing button in 10 seconds Set the current day and time 8 Preparatory operation 5 ex Monday 11 20 Press the button or to set the date The selected date will flash Press the button or to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the curren...

Page 17: ... set the operation mode Press the Mode button to set the operation mode Heat function is invalid for cool only type unit Operation mode setting 6 Time scale selection Press the buttons and for 2 seconds will alternatethe clock tieme display between the 12h 24h scale ...

Page 18: ...D HIGH keypad tone setting Press the buttons Swing and FUNC for 3 seconds to close the keypad tone Press the buttons again for 3 seconds to open the keypad tone Press the button or to set the room temperature Indoor Setting Temperature Range 17 30 C 62 86 F C F scale selection on some models Press the buttons and for 3 seconds will alternate the temperature display between the C F scale ...

Page 19: ... button to start up down swing function Press it again to stop When the Up Down swing function is activated the mark appears Swing function For the unit left right auto swing models only Press the buttons and for 3 seconds to activate the child lock function and lock all buttons on the wire controller Press the buttons again for 3 seconds to deactivate the child lock function When the child lock f...

Page 20: ...models 1 Press the button every time the louver swings 6 degrees 2 Press and hold the button for 2 seconds it turns into up down swing mode press ti again to stop When the Up Down swing function is activated the mark appears Not applicable to all the models Use Swing button to adjust the Up down airflow direction 1 Press the Swing button to activate the Up Down adjusting louver function The mark w...

Page 21: ...uence that goes from the icon means the four louvers move at the same time 9 Operation 3 And then use Swing button to adjust the Up Down airflow direction of the selected louver 0 1 2 3 4 0 Press the FUNC button to set the turbo or Ifeel function The select function icon will flash then press the Confirm button to confirm the setting ...

Page 22: ...nit or the wire controller Follow me function indication Turbo function on some models Under COOL HEAT mode press the FUNC button to activate the turbo function Press the button again to deactivate the turbo function When the turbo function is activated the mark appears When the follow me function indication appears the room temperature is detected at the wire controller ...

Page 23: ...ner operation starts after the time has passed Off timer Use this timer function to stop air conditioner operation The timer operates and air conditioner operation stops after the time has passed On and Off timer Use this timer function to start and stop air conditioner operation The timer operates and air conditioner operation starts and stops after the time has passed 10 Timer functions ...

Page 24: ... Confirm button and the Timer display is flashing Press the Confirm button again to finish the settings 3 ex Off timer set at 18 00 4 Press the button or to set the time After the time is set the timer will start or stop automatically Press the Timer button to select the or ...

Page 25: ...he On and Off TIMER Press the Timer button to select the 1 2 Press the Confirm button and the Clock display is flashing 3 Press the button or to set the time of On timer and then press the Confirm button to confirm the setting 4 5 Press the button or to set the time of Off timer ...

Page 26: ...rm Weekly timer setting 1 Press the button or to select the day of the week and then press the Confirm button to confirm the setting 2 Day of the week setting Press the button or to set the time of On timer and then press the Confirm button to confirm the setting ON timer setting of timer setting 1 3 ...

Page 27: ... and then press the Confirm button to confirm the setting NOTE The weekly timer setting can be returned to the previous step by pressing Back button The time of timer setting can be delete by pressing Day off botton The current setting will be restored and withdrawn the weekly timer setting automatically when there is no operation for 30 seconds Up to 4 timer settings can be saved for each day of ...

Page 28: ...rily And the air conditioner will turn on automatically until the time of On timer ON OFF ON OFF 8 00 12 00 14 00 17 00 10 00 ex If press the POWER button once and quickly at 10 00 The air conditioner will turn on at 14 00 2 When press the Power button for 2 seconds the air conditioner will turn off completely at the same time cancel the timing function Press the Timer button while is displayed on...

Page 29: ...ss the Day off button to set the DAY OFF 3 5 To cancel Follow the same procedures as those for setup 4 ex The DAY OFF is set for Wednesday The DAY OFF can be setted for other days by repeating the steps 2 and 3 The mark is hidden Notes The DAY OFF setting is cancelled automatically after the set day has passed Press the button or to select the day in this week ...

Page 30: ...py mode ensures ease of making reservations 2 Press the button or to select the day to copy from During the weekly timer pressing the Del button once display Press this button twice display and wait 3 seconds to confirm It means the unit will override 1 hours Press this button three times display and wait 3 seconds to confirm It means the unit will override 2 hours ex If press the DEL button to se...

Page 31: ...t the day to copy to Press the Confirm button to confirm the settings Press the Back button to back to the weekly timer 5 Press the Copy button to confirm Other days can be copied by repeating step 4 and 5 ex Copy the setting of Monday to Wednesday The mark flashes quickly 6 7 8 11 Weekly Timer 1 ...

Page 32: ...speed appear on the LCD Press CONFIRM to enter the setting time process Press or to select the day of the week and then press CONFIRM 12 Weekly Timer 2 Weekly timer setting 1 Press Timer to select the and press Confirm 2 Day of the week setting ON timer setting of timer setting 1 3 ...

Page 33: ...o set the operation mode then press CONFIRM Press or to set the time then press CONFIRM 12 Weekly Timer 2 ex Tuesday time scale 1 IMPORTANT Up to 8 scheduled events can be set on one day Various events can be scheduled in either MODE TEMPERATURE and FAN speeds 4 Time setting 5 Operation mode setting 6 Room temperature setting ...

Page 34: ...ent scheduled events can be set by repeating steps 3 through 7 8 Additional days in a one week period can be set by repeating steps 3 through 8 9 NOTE The weekly timer setting can be returned to the previous step by pressing BACK The current setting is restored The controller will not save the weekly timer settings if there is no operation within 30 seconds ...

Page 35: ...mer starts automatically ex To cancel The timer mode can also be canceled by changing the timer mode using Timer Press the Power buttons for 2 seconds to cancel the timer mode To set the DAY OFF for a holiday After setting the weekly timer press CONFIRM 1 Press or to select the day of the week 2 ...

Page 36: ...me procedures used for setup 4 ex The DAY OFF is set for Wednesday Set the DAY OFF for other days by repeating the steps 2 and 3 Copy out the setting in one day into the other day In the weekly timer press CONFIRM 1 A scheduled event made once can be copied to another day of the week The scheduled events of the selected day of the week will be copied The effective use of the copy mode ensures the ...

Page 37: ...nfirm the settings Press BACK to revert to the weekly timer 5 Press COPY to confirm Other days can be copied by repeating steps 4 and 5 ex Copy the setting of Monday to Wednesday The mark flashes quickly 6 7 8 Press or to select the day to copy to 2 Press or to select the day to copy from ...

Page 38: ...ess or to select the day of the week and then press CONFIRM Press or to select the setting time want to delete The setting time mode temperature and fan speed appear on the LCD The setting time mode temperature and fan speed can be deleted by pressing the DEL day off 3 ex Delet the time scale 1 in saturday ...

Page 39: ...te the system according to the following procedures The error displayed on the wire controller are different from those on the unit If error code appears please check the Owner s And Installation Manual and SERVICE Manual EMC and EMI comply with the CE certification requirements MALFUNCTION PROTECTION DEFINE DISPLAY DIGITAL TUBE NO 1 Error of communication between wire controler and indoor unit ...

Page 40: ... air conditioning unit is off into the query function of temperature press or to select SP press Confirm to adjust the static pressure value When the air conditioning unit is off into the query function of temperature press or to select AF press Confirm into test mode press Back or press ON OFF or press Confirm drop out of test mode In AF mode 3 6 minutes test completion automatically exits if the...

Page 41: ...s Confirm into setting state press or to select the temperature then press Confirm to complete it compensation temperature Follow me function temperature compensation When the air conditioning unit is off into the query function of temperature press or to select tyPE Press Confirm into setting state press or to select the type then press Confirm to complete it CH CC HH NA ...

Page 42: ...o setting state press or to select then press Confirm to complete it When the air conditioning unit is off into the query function of temperature press or to select tHI or tLo Press Confirm into setting state press or to select the temperature then press Confirm to complete it The highest setting temperature range 25 C 30 C The lowest setting temperature range 17 C 24 C Highest value setting funct...

Page 43: ...L and HEAT model The temperature range was restored to 17 C 30 C Remote receiving function is restored to be effective Restore factory Settings Restore factory Settings When the air conditioning unit is off into the query function of temperature press or to select INIt the temperature zone displayed Press Confirm into setting state press or to select to ON then press Confirm to complete it ...

Page 44: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Reviews: