background image

Standard

IEC60335-1

Contents

. Technical Parameters · · · · ·1

. Structure  · · · · · · · · · · · ·  1

. Product Installation  · · · ·  1

. Instructions for use   · · · · 2

. Precautions · · · · · · · · · · · · ·  · · 2

. Maintenance · · · · · · · · · · · · · ·  3

. Troubleshooting · · · · · · · · · · · 3

  

 

. Technical Parameters

   

. Product Installation

• 

Preparation and inspection before installation

1. The installation position must be more than 30cm away from gas appliances, electric heating appliances or other heat sources, 
or separated by board.
2. Before installation, the strength and surface flatness of the installation place must be checked, and the skew and dislocation of 
the chamber door shall not appear.
3. It shall be installed in the place that can bear the weight of the chamber.
4. When installing, carefully check other factors that may cause the chamber to have malfunctions or accidents.
5. Impulse current is about 5 amperes, please check electrical capacity.

UVCC090 36W UVC Disinfection Chamber Instructions 

. Structure 

Model

UVCC090 36W XX(01~20) 

Dimensions

470*440*400mm

Volume

48L

Weight

9.4kg

Power

36W

Input Voltage

220-240V~

Frequency

50-60Hz

Fuse Protection

5A, 250V~

Disinfection Method

253.7 nm, UVC 

Operating Temperature Range

10-40°C

Storage Temperature Range

-20-60°C

Ambient Humidity Range

10%-90%

UV Risk Group

The risk group of ultraviolet radiation in 
the disinfection chamber is RG3, and the 
outside of the chamber is RG0

• 

WARNING

1. 

Please ground reliably so as not to cause electrical shock accidents caused by poor grounding.

2. Make sure to disconnect the power supply before you move the disinfection chamber.

UVCC090