background image

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

! IMPORTANT SAFEGUARDS !

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY

PRECAUTIONS SHOULD ALWAYS BE  FOLLOWED, 

INCLUDING THE FOLLOWING:

SAVE THESE INSTRUCTIONS

Ni - Cd

1.

Caution:

• High voltage will be present on the output wires and terminals if batteries are installed and inverter

connector is joined or if AC power is supplied to the switched and unswitched terminal.

• Ensure input and output primary wiring connections are made to the proper terminals. Damage to product

may occur if miswired.

• Ensure load voltage requirements (120 or 277 Vac) match the output ratings of this product or damage to

the load devices may occur.

• The batteries should be installed and charged within 8 months of manufacture’s date code. See step #6

for date code information.

2. This product is suitable for use in damp locations where the ambient temperature is 0°C through 40°C,

depending on load. See output ratings on product label for details. This product is not suitable for heated
air outlets and wet or hazardous locations.

3. Make sure all connections are in accordance with the National Electrical Code or Canadian Electrical Code

and any local regulations.

4. To reduce the risk of electric shock, disconnect both the normal and emergency power supplies and the

inverter connector of the emergency lighting inverter before servicing.

5. Do not install near gas or electric heaters.
6. An unswitched AC power source is required. The AC voltage rating of this equipment is specified on the

product label. Do not connect equipment to any other voltage.

7. Equipment should be mounted securely in locations and at heights where it will not be readily subjected to

tampering by unauthorized personnel.

8. The use of accessory equipment and replacement parts not recommended by the manufacturer may cause an

unsafe condition.

9. Do not use this equipment for other than its intended purposes.

 10. The battery is field replaceable. Contact manufacturer for information on replacement. Use caution when

replacing battery. Dispose of the battery properly. Do not incinerate.

Installation and Operation Instructions

ELI-S-100

06/21/17

© Philips Emergency Lighting

WITH DIMMING CAPABILITIES

ELI SERIES EMERGENCY LIGHTING INVERTERS

THIS PRODUCT INCLUDES RECHARGEABLE LEAD-ACID BATTERIES. 

THE BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Summary of Contents for Bodine ELI Series

Page 1: ...s are in accordance with the National Electrical Code or Canadian Electrical Code and any local regulations 4 To reduce the risk of electric shock disconnect both the normal and emergency power supplies and the inverter connector of the emergency lighting inverter before servicing 5 Do not install near gas or electric heaters 6 An unswitched AC power source is required The AC voltage rating of thi...

Page 2: ...stalled Remove the knockouts to install input and output wiring conduit fittings Extend AC supply output load wiring and optional control wiring into the equipment enclosure using appropriate wiring hardware and methods Illustration 1 details the locations of the various wiring terminals and switch locations needed for the remainder of the installation Reference Illustration 1 for steps through 2 ...

Page 3: ...n 1 See Step 4 for switch settings STEP 4 SETTING THE OUTPUT DIMMING LEVEL OPTIONAL Upon loss of normal AC power the Emergency Lighting Inverter s internal 0 10 VDC circuit will output a dimming voltage to the luminaires PCB Switches S701 and S702 are used to set the 0 10 VDC dimming level See Illustration 4 which details the switch positions for the desired level of dimming Refer to Illustration ...

Page 4: ...YELLOW RED BLACK TO PCB BOARD J8 Attach the battery wires as shown in the illustration Refer to Illustration 5 for connections to these auxiliary relay contacts Ensure the ratings of the contacts are not exceeded The relay contacts are rated for 1 A at 30 VDC or 1 A at 120 VAC Install the batteries as shown With the unit secured to the mounting surface place the batteries into the enclosure as ill...

Page 5: ...placed whenever it will no longer operate the connected fixtures for the duration of a 90 minute test The battery supplied has a life expectancy of 4 years when used in normal ambient temperature of 72 degrees F Fuse The fuses contained within this product are field replaceable For fuse locations see illustration 1 To replace fuses remove AC Power from the product and disconnect the inverter conne...

Reviews: