Performance Recessed CFL Downlighting

  1001FDIC

Page 1 of 1 

5" Aperture, 1 Light, Compact Fluorescent, IC AirSeal

®

,  Dimming, Frame-In Kit

1

2

3

4

5

6

7

Reflector Trim

Frame-in Kit

Features

1.  Housing:

 .028" (#21ga.) aluminum. UL listed for direct contact with thermal 

insulation. AirSeal

®

 housing minimizes air leakage to less than 2 CFM at 1.57 

PSF (or 75pa), which complies with Model Energy Code (Section 602.3.3) and 
Washington State Energy Code (Section 502.4) and reduces heat loss and 
condensation in ceiling. Access door for inspection of junction box.

2.  Mounting Frame: 

.032 (#22 ga.) galvanized steel. Accommodates ceilings 

up to 1 1/2" thick. 3/8" deep integral lip. Locks into position along length 
of mounting bars with locking screw and bendable slot. Four slots are 
positioned 90° apart to simplify alignment. Push-in/twist-out roto-clips hold 
reflector flush to ceiling.

3.  Junction Box:

 2" X 4" X 3 1/2" (22 cu. in) .032" (#22 ga.) galvanized steel. UL 

listed for maximum of 8 (#12 ga.) 90°C through branch circuit conductors.

4.  Mounting Bars:

 .059" (#16 ga.) galvanized steel. Bars pivot for easy 

attachment and wire-in below ceiling line. Bars extend to accommodate 16" 
to 24" O.C. joist spacing. Bars can accommodate 12" O.C joist spacing after 
a slight field modification (see Instruction Sheet). Features integral self 
tapping phillips screws for secure attachment to wood or metal construction. 
Attaches to T-bar ceilings without the need of accessories. 

5.  Ballast:

 Mounted inside housing. 120V or 277V UL Listed Electronic Dimming 

Ballast, end of lamp life protection, class “P” thermally protected, class “A” 
sound rating. 

6.  Socket:

 Four-pin base, molded thermoplastic socket, prewired with No. 18 

AWM leads to ballast.

7.  Socket Housing:

 .036" (#20ga.) Galvanized Steel housing attaches to 

reflector trim by spring clip for precise optic alignment.

Options & Accessories

Extra-Thick Ceiling
Mounting Ring:

 

1967B 

- 1 1/4" to 2" thick ceilings

Labels

cULus Listed (Type I.C., Suitable for Damp Location), I.B.E.W.

Complies with Air Leakage Requirements stated in the Model Energy Code and 
the Washington State Energy Code.

AirSeal

®

 is a registered trademark of Lightolier

Top View

Overall Length

Ceiling Opening: 5 1/4"

Overall Width

10 3/8"

13" Min.

24" Max.

15 5/16"

12 1/4"

Height: 7 1/4"

Complete Fixture consists of Frame-In Kit and Reflector Trim. Select each separately.

Uniframe

 

Frame-In Kit

Uniframe

 Compact Fluorescent Performance Series Reflector Trims

Horizontal Open

Horizontal Wall  
Wash - Single

Horizontal Wet Location
Lensed / Diffused

Horizontal  
Cross Blade

1001FDICMX1**

(Advance Mark10 – 120v)
26w Triple
GX24q-3 Base
120v – 0.26amp max

1001FDICMX2**

(Advance Mark10 – 277v)
26w Triple
GX24q-3 Base
277v – 0.11amp max

1001HCL
1001HCD
1001HWH

1001HCLSW
1001HCDSW
1001HWHSW

Clear Lens 

Fresnel

1001HCLC

 

1001HCLF

1001HCDC

 

1001HCDF

1001HWHC

 

1001HWHF

Opal Lens

1001HCLO
1001HCDO
1001HWHO

1001HACB
1001HWHCB

Universal Series Reflector Trims 

(Reference Trim Spec Sheet for Recommended Lamping)

Cone

Satin Cone

Baffle

Wall Wash

Wet Location

1012* 

1071

1013* 

1045

1013BK* 

1046

1013WH 

1046CD

1013CD*

1008*
1010*

1005*
1005BNM
1005WH
1076
1076WH

1035
1035WH
1085
1095
1096
1096CD

1024
1078

*Add NM suffix to catalog number 
for Natural Metal flange and finish.

**Add N to catalog number 
for preset nails.