background image

http://www.nais-e.com/vision/
Panasonic...the new name for 

Matsushita Electric Works, Ltd.

User's Manual

Summary of Contents for LightPix AE20

Page 1: ...http www nais e com vision Panasonic the new name for Matsushita Electric Works Ltd User s Manual ...

Page 2: ...safety instruction is not observed WARNING Do not use the product in the environment where combustible gas presents This might cause explosion Never attempt to disassemble or alter the product Failure to do so might result in an electric shock and physical damage CAUTION Be sure to ground the product Failure to do so might result in an electric shock Do not touch the terminals while the power is o...

Page 3: ...t to the Operation Unit 13 3 2 2 Connection of the Operation and Finder Units 14 3 3 Fixing and Removing the Main Unit 15 3 3 1 Main Unit 15 3 3 2 Operation Unit 18 3 3 3 Finder Unit 19 3 3 4 Installation Environment 20 3 4 Input Output Cables for Connecting Power Supply Unit or External Devices 21 3 4 1 Sequence of Input Output Signals 21 3 4 2 Input Signal 22 3 4 3 Output Signal 23 3 4 4 Power S...

Page 4: ...etting Up the Judgement Criteria in JUDGEMENT CRITERIA SETTING mode 68 4 4 6 Inspection Execution 69 4 5 Peak Detection 70 4 5 1 Overview of Peak Detection 70 4 5 2 Setting Procedure and Modes 72 4 5 3 Setting Up the LightPixAE20 in CONFIGURATION 73 4 5 4 Teaching in TEACHING Mode 75 4 5 5 Setting Up the Judgement Criteria in JUDGEMENT CRITERIA SETTING Mode 79 4 5 6 Inspection Execution 80 4 6 Mea...

Page 5: ... 6 4 A List of Data Registers for Each Application 116 6 4 1 Color Area Judgement 116 6 4 2 Color Pattern Matching 119 6 4 3 Edge Detection 122 6 4 4 Peak Detection 125 6 4 5 Measurement 128 7 About AETOOL and GT11 133 7 1 AETOOL 134 7 1 1 Overview of AETOOL 134 7 1 2 Obtaining and Installing the AETOOL 135 7 1 3 Connecting to a Computer 135 7 2 GT11 136 7 2 1 Functions of GT11 136 7 2 2 Sample Da...

Page 6: ...normal voltage might damage the internal circuit If you use a power supply unit without a protection circuit supply power through a protective device such as a fuse About grounding Do not commonly use the ground with other devices Grounding should be as close as the main unit as possible and keep the distance short Noise Countermeasure Do not bundle the optional cable connecting between the main u...

Page 7: ...nd remodel the LightPixAE20 or change its internal settings A breakdown damage or destruction caused by disassembling remodeling the LightPixAE20 or not following the instructions described in the manuals will not be covered by our guarantee Do not change or set items that should not be as described in the manual or the specification Breakdown damage or destruction resulting from changing or setti...

Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...

Page 9: ...ment the images stored in the main unit or save them as bmp file In addition with the operation unit and finder unit you can check the current image or modify the scanning conditions and with our programmable display GT11 you can change settings or control start of code read The operating instructions mainly for the operation unit and finder unit are described in this manual Refer to the AETOOL he...

Page 10: ...t the device onto the operation unit before use Do not directly connect the finder unit to the main unit AETOOL The AETOOL is software exclusively for LightPixAE20 Before using this software install it to the PC connected to the LightPixAE20 with USB cable AB type The key features of this software are shown in the table below Features Description Transferring the inspection application to the main...

Page 11: ... extraction image detects the same image as the saved base image template Edge Checks whether or not the detected edges of the object move from the registered base position Peak Finds out whether or not the detected vertices of the object move from the register base position Measurement Finds out whether or not the measured max min values in the horizontal and vertical directions are equal to the ...

Page 12: ...Chapter 2 Names and Functions of Parts 5 ...

Page 13: ...USB2 0 or 1 1 max cable length 5m OUT1 3 Output state of inspection results The OUT1 3 LEDs goes on when each signal is output READY The READY LED goes on when the main unit performs no process The LightPixAE20 can receive inspection start signal TRIGGER signal in RUN or RUN VIEW mode from the external devices only while the READY signal is being output 5 LED indicators ALARM The ALARM LED goes on...

Page 14: ... the next page for further details 2 Operating buttons Used for operating the main unit There are eight operating buttons 3 Port for connecting to the main unit Used for connecting to the main unit Use the cable ANE2813 or ANE2823 to connect to the main unit 4 Connector for finder unit Used for connecting to the finder unit Do not connect any other device to the port for the main unit Failure to d...

Page 15: ...llel output signal READY is ON LOCK RUN VIEW mode Means the lock function is activated In this mode you cannot operate the LightPixAE20 ALARM Red RUN VIEW mode TEACHING mode May be displayed when the device is in the other modes Displayed when the parallel output signal ALARM is ON OUT1 3 RUN RUN VIEW mode Represents output state of parallel output signals OUT1 3 The signals that are turned on are...

Page 16: ... the Lock function To lock the operation unit 1 Press the buttons 1 and 8 on the operation unit at the same time for approximately three seconds The word Lock appears on the LCD display refer to the previous page for details of displayed texts To unlock the operation unit 1 Press the buttons 1 and 8 on the operation unit at the same time for approximately three seconds The word Lock disappears Eve...

Page 17: ...ng connector Used for connecting the operation unit Expected service life of the backlight is approx 40 000hours at operating ambient temperature 25ºC The LightPixAE20 comes with a built in Backlight OFF TIMER function This function would be helpful if you want to turn the device off in 10 30 or 60 minutes Refer to Section 4 7 Detailed Functions in CONFIGURATION Mode for more details of Backlight ...

Page 18: ...Chapter 3 Installation and Wiring 11 ...

Page 19: ...unit and PLC To control the LightPixAE20 with external devices such as power supply unit and PLC and import measurement results 15 3 Serial RS232C PLC POT etc To receive inspection results control the LightPixAE20 by sending commands from external devices and import measurement results 26 4 AETOOL installed PC To perform all operations without using the operation unit and finder unit 135 12 ...

Page 20: ...ied cable ANE2813 cable length 3m or ANE2823 cable length 3m to connect the main unit to the operation unit When connecting to only the operation unit with the finder unit When connecting the main unit to the operation unit with the finder unit and to the external devices such as PLC and POT via RS 232C 13 ...

Page 21: ...unit until it clicks To remove the operation unit from the finder unit 1 Hold the finder unit with one hand 2 Hold the operation unit with the other hand and lift the operation unit in the arrow direction When using the finder unit mount the operation unit on the finder unit first and connect the devices with the optional cable for connecting to the main unit Do not mount the operation unit on the...

Page 22: ...oving the Main Unit 3 3 1 Main Unit Fixing the main unit on a wall Use the three holes on a side of the main unit to fix it on a wall Avoid installing the main unit as the following figures shown below Wrong Examples 15 ...

Page 23: ...s Installation angle If you want to capture a shiny object the light emitted from white LED may interfere with the object due to the mirror reflection from it so slant the main unit Disturbance light of which illumination intensity varies at the time of measurement negatively affects the measurement results Shield the device from any disturbance light The larger the installation angle the greater ...

Page 24: ...Ferrite core must be used for the wirings as the figures shown below 3 Mounting plate ANE8870 separately sold must be used for grounding Mount Plate Product No ANE8870 Manufacturer Product No Ferrite Core TDK CO LTD ZCAT1730 0730A Installation space between the multiple units Keep the enough space between the units to prevent the lights emitted from each unit from interfering with each other see t...

Page 25: ...he mounting frame into the rear side of the operation unit then tighten the mounting frame with the screws Sizes of the mounting plate Use 1 to 5mm thick panel To install a single unit To install multiple units To remove the operation unit 1 Loosen screws 2 Remove the mounting frame while pulling the tabs in the arrow directions 18 ...

Page 26: ...eration unit first mount the finder unit onto the front side of the mounting plate and then insert the mounting frame into the rear side of the fixing plate Sizes of the mounting plate Use 1 5mm thick panel To install a single unit To install multiple units 19 ...

Page 27: ...s and devices generating large switching surge be sure to keep more than 100mm space between the LightPixAE20 and these devices Noise Countermeasure Do not bundle the optional cable connecting between the main unit and the operation unit and input output signal cables connecting to the main unit together with motor or power cables Ensure that they are at least 100m apart Keep the signal cables as ...

Page 28: ...itching from TEACHING mode to RUN mode Orange TYPE1 Yellow TYPE2 Purple TYPE3 Input Specifies product type number for switching product types Binary input Specify the number subtracted one from the product number White Black COM OUT COM for output Black READY Ready completion signal White Yellow ALARM Alarm signal White Brown OUT1 Judgement result output 1 White Red OUT2 Judgement result output 2 ...

Page 29: ...as it may cause abnormal operation Current leakage at the input side may not turn input off In such as case connect a resistor following the figure below If Input to the LightPixAE20 is not turned off due to current leakage when 2 line photoelectric sensor or proximity sensor is used connect a bleeder resistor Even in cases where in line LEDs such as LED reed switches are connected with an input c...

Page 30: ...d capacity so that you can connect the LightPixAE20 to a PLC etc Do not connect directly with a device having a high load capacity such as a valve without passing it through our Power Photo relay The output circuit contains no built in fuse If it is necessary to prevent from burning out the output circuit in the event of output load short circuit mount a fuse externally However it may not be able ...

Page 31: ...g from input output circuits it is recommended that the power source for the LightPixAE20 and for input output should be separately supplied Turn the LightPixAE20 ON OFF at the Primary Side Turn the LightPixAE20 on off at the primary side 100 V AC If you turn the device on off at the secondary side 24 V DC the fuses of the device may melt down Consider the Electric Power Sequence Consider the powe...

Page 32: ...ter 3 4 6 Comformity to the EMC standard The LightPixAE20 will comply with the EMC standards EN61000 6 4 EN61000 6 2 in EMC Directive EMC Directive 89 336 EEC The product must fulfill the following conditions 1 No USB communication 2 Ferrite core must be used for the wirings as the figures shown below 3 Mounting plate ANE8870 separately sold must be used for grounding Mount Plate Product No ANE887...

Page 33: ...3 5 1 Connecting to the External Devices When using the operation unit and finder unit When NOT using the operation unit and finder unit Three cable system for RS 232C Assignment Cable color Signal Yellow SD Red RD Black SG 26 ...

Page 34: ...3 5 2 Wiring Method Example of cable connections Example of cable connection with PLC Example of cable connection with Matsushita programmable display GT11 27 ...

Page 35: ...ns with multiple main units If you control multiple main units with one host including PLC and PC use the RS 232C to RS485 RS485 to RS232C commercially available conversion adapter In this case up to 31 main units can be connected to one host max transmission distance 1200m Assign device numbers unit number 0 and 1 31 to the host and main units respectively Assign the device number unit number whe...

Page 36: ...Chapter 4 Inspection Applications 29 ...

Page 37: ...The images of which specific colors were extracted are saved and they are used for inspection 4 Edge Finds out whether or not the detected edges of the object moves from the registered base position This application is available for inspection for binary black and white images 5 Peak Finds out whether or not the detected vertices of the object moves from the registered base position This applicati...

Page 38: ...nternal trigger ON At least 30ms is required for inspection If the inspection time exceeds 30ms it will become equal to the one required for internal trigger OFF For example if exposure time for Color Judgement 5 ms Internal trigger Inspection time Explanation OFF 19 ms Computation time 10 exposure time 5 transmission time 4 ON 30 ms If the total time is less than 30ms when internal trigger is ON ...

Page 39: ...of the range NG judgement the OUT1 signal is turned off You can register one product type for each color and totally seven colors for seven product types but inspection is performed for each product type If you want to inspect the object in the color different from the color that is saved as the current product type change to the desired product type at the LightPix side first and continue the ins...

Page 40: ...ve if the object having an unregistered color or an registered color less than the area value you have set inspection result 0 is output This is because the unit judges that the object does not fulfill the area value saved as each product type no 1 7 If the object having the color saved as multiple product types is judged as OK the lowest product type number is output as an inspection result For C...

Page 41: ...ING mode In the TEACHING mode register extraction color at the same time set the exposure time or range for measuring area inspection area and area for setting extraction color Page 37 5 Set judgement criteria in JUDGEMENT CRITERIA SETTING mode In JUDGEMENT CRITERIA SETTING mode set the limits of area values min to max If the area values are within the limit the LightPixAE20 judges as OK Page 41 6...

Page 42: ...6 button for approximately three seconds SAVE CANCEL SAVE SAVE function Saves the current settings If you want to save the settings select SAVE and press the 6 button for approximately three seconds TEACH OK OFF Teaching Kenly OK NG Allows you to select whether you want to execute a teaching for OK products only or both OK product and NG product B L PTN ON OFF10 OFF30 OFF60 Backlight Pattern funct...

Page 43: ...utomatically performs continuous inspections When OFF inspection is performed when TRIGGER signal is input INI T 1 7 Initial Type The selected product type number when the LightPixAE20 is turned on available only for colored areas SPEED High Middle Low Speed Allows you to select the processing time of measurement available Color Judgement only VER Version Version size of view range and system and ...

Page 44: ... a teaching the minimum and maximum limits for the area set in JUDGEMENT CRITERIA SETTING mode is automatically set but the area value varies depending on the type of teaching See the table below Type Allowable range to be set automatically Teaching for OK product only Sets to the area value when executing a teaching 5 Teaching for OK and NG products Sets the max min area limit to the middle numbe...

Page 45: ...area If you want to perform a teaching at this point press 6 and then 1 MOVE Moves the inspection area If you want to execute teaching press 6 and then 1 T SIZE Resizes the Color Extraction area If you want to execute a teaching at this point press 6 first and then 1 after resizing T MOVE Moves the Color Extraction area 6 Executes a teaching Teaching is performed for the current product type DONE ...

Page 46: ...ves the Color Extraction area 6 Executes a teaching Executes a teaching for OK product of the current product type STNG Indicates successful completion of teaching for OK products 6 Executes a teaching for NG products Executes a teaching for NG product of the current product type DONE Indicates successful completion of NG product teaching FAIL Indicates unsuccessful completion of teaching the ALAR...

Page 47: ... area to the left 4 Moves the inspection area to the right 8 Moves the inspection area up 7 Moves the inspection area down Adjustment of Color Extraction area size T SIZE X direction wide 3 Reduces the color extraction area 4 Enlarges the color extraction area Y direction length 7 Reduces the color extraction area 8 Enlarges the color extraction area Movement of Color Extraction area T MOVE 3 Move...

Page 48: ...ENT CRITERIA SETTING mode SET is displayed on the operation unit Top line Product type number and current min area limit Bottom line L min value minimum value to be set 7 Increases the min value 8 Decreases the min value Top line Product type number and current max area limit Bottom line H max value maximum value to be set 7 Increases the max value 8 Decreases the max value The current min and max...

Page 49: ...ults Inspection judgement results are output to the parallel ports of OUT1 to OUT3 See the table shown below Color Area Judgement results OUT3 OUT2 OUT1 OK Within the range OFF OFF ON NG Out of the range OFF OFF OFF Color Judgement Color Product type No OUT3 OUT2 OUT1 No applicable All NG OFF OFF OFF 1 OFF OFF ON 2 OFF ON OFF 3 OFF ON ON 4 ON OFF OFF 5 ON OFF ON 6 ON ON OFF 7 ON ON ON Internal Tri...

Page 50: ...digits including the numbers under the decimal point The digits under the decimal point differs depending on the type of unit Color Judgement Color Judgement When inspecting in RUN mode you can check the selected product type No and measured area value When inspecting in RUN mode you can check the selected product type No and measured area value Data Display Top line Product type numbers 1 to 7 Bo...

Page 51: ...te for each product type and seven colors and templates for seven product types in total If you want to detect the different object switch the product types at the LightPix side to continue to execute inspection Showing the template position A template is positioned within the inspection area and its X and Y directional distance from the left upper position to the center value of the template is i...

Page 52: ...d within the position of the saved template allowable range settable in JUDGEMENT CRITERIA SETTING mode the LightPixAE20 judges as OK Settings of teaching and judgement criteria X and Y are judged as OK X and Y or Y or Y are judged as NG X and Y are out of range Y is out of range X is out of range 45 ...

Page 53: ...ndidates Detected Candidates 1 and 2 Detailed conditions Similarity adjustment value What is similarity adjustment The degree that the image matches the template is called a degree of similarity The greater the degree of similarity the more similar the detected image The lower the degree of similarity the less similar the detected image If you wish to execute a strict inspection in order to detect...

Page 54: ...olor as the object you want to detect or the same pattern exist in the background as the part you want to detect For a searching for a rough image the degree of similarity for these objects or background may become reversely higher than or equal to the target object or part The unit detects only the image having the highest degree of similarity among the images having the degree of similarity more...

Page 55: ...ng in TEACHING mode In the TEACHING mode register extraction color and template base image at the same time set the exposure time or range for measuring area inspection area and area for setting extraction color Page 52 5 Set judgement criteria in JUDGEMENT CRITERIA SETTING mode In JUDGEMENT CRITERIA SETTING mode set the limits of area values min to max and the threshold value of degree of similar...

Page 56: ...ANCEL SAVE SAVE function Saves the current settings If you want to save the settings select SAVE and press the 6 button for approximately three seconds TEACH OK OKNG Teaching OK only OK NG Allows you to select whether you want to execute a teaching for OK products only or both OK product and NG product B L PTN ON OFF10 OFF30 OFF60 Backlight Pattern function Sets the backlight of the finder unit OF...

Page 57: ...ms in the 1 ms unit Capture Delay function Sets the time delay from TRIGGER signal input to image capture I TRR ON OFF Internal Trigger function When the function is set to ON the LightPixAE20 automatically performs continuous inspections When OFF it performs an inspection every time trigger signal input INI T 1 7 Initial Type The selected product type number when the LightPixAE20 is turned on ava...

Page 58: ...degree of similarity at the first step by decreasing the set value CAND2 1 50 Candidate2 Indicates the number of detection candidates at the second step CAND1 1 50 Candidate1 Indicates the number of detection candidates at the first step DETAL ON OFF Detail function Allows you to select whether or not to make the settings of computation conditions ON Make the detailed settings OFF Not make the det...

Page 59: ... OK product short distance Plus Distance value when executing a teaching 5 Minus Median between the distance values for OK product and NG product When the limit for NG product is higher than that for OK product long distance Plus Median between the distance values for OK product and NG product Minus Distance value when executing a teaching 5 Notice on teaching After changing to TEACHING mode set e...

Page 60: ...eaching press 6 and then 1 T SIZE Resizes the Color Extraction area If you want to execute teaching press 6 and then 1 T MOVE Moves the Color Extraction area If you want to execute a teaching at this point press 6 first and then 1 after resizing M SIZE Resizes the template area If you want to perform a teaching at this point press 6 and then 1 M MOVE Moves template area If you want to perform a te...

Page 61: ...ime Lower line M85 the threshold value for degree of similarity 6 Executes a teaching Teaching is executed for the current product type ADJ Teaching is being executed STNG Teaching for OK product Successful teaching FAIL Teaching failure ALARM signal is output 6 Teaching Execution Executes a teaching for NG product of the current product type Values two digits The degree of similarity detected dur...

Page 62: ...tion and color extraction areas You can resize these three types of area following the common way The figure on the left is an example inspection area Area Display Area color Inspection SIZE Blue Color extraction T SIZE Black Template M SIZE Pink X direction wide The 3 button Reduces the width The 4 button Enlarges the width Y direction length The 7 button Reduces the length The 8 button Enlarges ...

Page 63: ...Set the degree of similarity of the detected image in this mode too Operation in JUDGEMENT CRITERIA SETTING mode The number in in the table below represents the button number of the operation unit see the figure on the right In INSPECTION or RUN mode In JUDGEMENT CRITERIA SETTING mode SET is displayed Top line Product type number and current allowable limit Bottom line X allowable limit to be set ...

Page 64: ...he allowable range ON ON ON Image Detection X OK An image having more than the specified degree of similarity is detected X position distance Within the limit Y position distance Out of the limit OFF ON ON Image Detection Y OK An image having more than the specified degree of similarity is detected X position distance Out of the limit Y position distance Out of the limit ON OFF ON Image Detection ...

Page 65: ...milarity 0 100 When the unit failed to detect an image having more than the degree of similarity the screen display is as the figure shown right Product type switch The 3 4 and 5 buttons Changes the product types Once the product types are switched OUT1 to 3 are reset Range of position data Type Data ANE2000 ANE2010 ANE2020 ANE2030 X 0 to 2 00 0 to 10 00 0 to 30 00 0 to 80 00 Y 0 to 1 60 0 to 8 00...

Page 66: ... direction and from left to right in the X direction and detects a point changing from white to black or from black to white If you could detect an edge changing points in whole scanning lines either in Y or X direction Therefore the unit cannot detect any edge in some scanning lines in the following images and judges as NG The example images where edges can be detected and the detection edge dist...

Page 67: ... or Y for which a teaching was executed must be detected Detection edge distance does not exceed the edge distance for which a teaching was executed allowable range set in JUDGEMENT CRITERIA SETTING mode Example Teaching and Setting Judgement Criteria OK Judgement NG Judgement Cannot detect any edge Out of range Cannot detect any edge in the direction for which a teaching was executed 60 ...

Page 68: ...ns Page 62 4 Run a teaching In TEACHING mode In the TEACHING mode register edge direction and distance at the same time set the exposure time or range for measuring area inspection area and area for setting extraction color Page 64 5 Set judgement criteria In JUDGEMENT CRITERIA SETTING mode In JUDGEMENT CRITERIA SETTING mode set the allowable limits of edge distance for teaching execution Page 68 ...

Page 69: ...he 6 button for approximately three seconds SAVE CANCEL SAVE SAVE function Saves the current settings If you want to save the settings select SAVE and press the 6 button for approximately three seconds TEACH OK OKNG Teaching OK only OK NG Allows you to select whether you want to execute a teaching for OK products only or both OK product and NG product B L PTN ON OFF10 OFF30 OFF60 Backlight Pattern...

Page 70: ... delay from TRIGGER signal input to image capture I TRR ON OFF Internal Trigger function When the function is set to ON the LightPixAE20 automatically performs continuous inspections When OFF inspection is performed when TRIGGER signal is input INI T 1 7 Initial Type Selected product type number when the LightPixAE20 is turned on available only for colored areas SPEED High Middle Low Speed Allows ...

Page 71: ...roducts only Teaching for OK and NG products When executing a teaching the allowable limit specified in JDGEMENT CRITERIA SETTING mode is automatically set but the max and min values differ depending on the type of teaching Type Allowable range to be set automatically Teaching only for OK Sets to the ara value when executing a teaching 5 Teaching for OK and NG products When the limit for NG produc...

Page 72: ...m a teaching at this point press 6 first and then 1 SIZE Resizes the inspection area If you want to execute a teaching at this point press 6 first and then 1 after resizing MOVE Moves inspection area 6 Executes a teaching for the current product type Teaching for the current product type is executed DONE Indicates successful completion of teaching FAIL Abnormal termination of teaching the ALARM si...

Page 73: ... 6 Executes a teaching for the current product type Teaching for the current product type is executed STNG Teaching for OK products Normal completion FAIL Abnormal termination of teaching The ALARM signal is output 6 Executes a teaching Executes a teaching for NG product of the current product type DONE Teaching for NG product Normal completion FAIL Abnormal teaching the ALARM signal is output 5 R...

Page 74: ...ges the width Y direction length The 7 button Reduces the length The 8 button Enlarges the length The inspection area is displayed in blue MOVE Movement of inspection area position The 3 button Moves the inspection area to the left The 4 button Moves the inspection area to the right The 8 button Moves the inspection area up The 7 button Moves the inspection area down 67 ...

Page 75: ...nal edge is saved default or X directional edge is displayed Ref Y Base edge distance Y direction The edge distance saved by teaching is displayed Even if X directional edge is saved default or Y directional edge is displayed Per X Allowable range X direction Settings of X directional allowable limit 8 Increases the value extends the allowable range 7 Decreases the value reduces the allowable rang...

Page 76: ... the detected edge Y Y directional distance of the detected edge Lower line Data value Detection edge distance Four digits including the numbers under the decimal point The number of digits under the decimal point differs depending on the type of unit When the unit failed to detect an edge the screen display is as the figure on the right Data type in the edge direction saved by teaching and the da...

Page 77: ...e range the image is judged as OK and OUT1 is turned ON Detectable and undetectable peaks The unit detects two points in the X and Y directions by computing the intersected point The X and Y directional distance between the left upper part of the point in the inspection area and the detected point is displayed as a the position of the detected point in mm Example detectable images These are exampl...

Page 78: ...allowable range set in the JDGEMENT CRITERIA SETTING mode If either of the directional distances is out of range the unit judges it as NG Example Settings of teaching and judgement criteria OK judgement The shape of the object is different but the peak distance is within the allowable range The brightness between the object and the background is reversed but the peak distance is within the allowab...

Page 79: ...G mode In the TEACHING mode register a distance between the left upper of the point in the inspection area and the detected point set the exposure time or range for measuring area inspection area and area for setting extraction color Page 75 5 Set judgement criteria In JUDGEMENT CRITERIA SETTING In JUDGEMENT CRITERIA SETTING mode set the allowable distance limit between the left upper inspection a...

Page 80: ...n for approximately three seconds SAVE CANCEL SAVE SAVE function Saves the current settings If you want to save the settings select SAVE and press the 6 button for approximately three seconds TEACH OK OKNG Teaching OK only OK NG Allows you to select whether you want to execute a teaching for OK products only or both OK product and NG product B L PTN ON OFF10 OFF30 OFF60 Backlight settings function...

Page 81: ...me delay from TRIGGER signal input to image capture I TRR ON OFF Internal Trigger function When the function is set to ON the LightPixAE20 automatically performs continuous inspections When OFF it performs an inspection every time trigger signal input INI T 1 7 Initial Type The selected product type number when the LightPixAE20 is turned on available only for colored areas VER Version Version size...

Page 82: ...ng for OK and NG products When performing a teaching the allowable distance limit specified in JUDGEMENT CRITERIA SETTING mode is automatically set but the distance varies depending on the type of teaching See the table below Type Allowable range to be set automatically Teaching for OK products only Sets to the distance between the left upper part of the point in the inspection area and the detect...

Page 83: ... time 8 Longer the exposure time If you want to perform a teaching at this point press 6 first and then 1 SIZE Resizes the inspection area If you want to perform a teaching at this point press 6 first and 1 MOVE Moves the inspection area 6 Executes a teaching Executes a teaching for OK product of the current product type DONE Indicates successful completion of teaching FAIL Abnormal termination of...

Page 84: ...tes a teaching for OK product of the current product type STNG Teaching for OK products Normal completion FAIL Abnormal termination of teaching The ALARM signal is output 6 Executes a teaching Executes a teaching for NG product of the current product type DONE Teaching for NGproduct Normal completion FAIL Abnormal teaching the ALARM signal is output 5 Returns to the top You can always switch the p...

Page 85: ...nlarges the width Y direction length The 7 button Reduces the length The 8 button Enlarges the length The inspection area is displayed in blue MOVE Movement of inspection area The 3 button Moves the inspection area to the left The 4 button Moves the inspection area to the right The 8 button Moves the inspection area up The 7 button Moves the inspection area down 78 ...

Page 86: ...SETTING The number in in the table below represents the button number of the operation unit see the figure on the right In INSPECTION or RUN mode In JUDGEMENT CRITERIA SETTING mode SET is displayed Ref X Base peak distance X direction Peak distance saved by teaching The value of X directional distance Ref Y Base peak distance Y direction Peak distance saved by teaching The value of Y directional d...

Page 87: ...istance of the detected point Y Y directional distance of the detected point TIME Calculation time Lower line Data value X Y directional distance Up to four digits including the numbers under the decimal point The digits under the decimal point differs depending on the type of device When any point is not detected the screen display is as the figure shown right Calculation time Less than two digit...

Page 88: ...he length mean in the LightPixAE20 The LightPixAE20 finds out the pixels of the object color from left to right and from right to left within an inspection area The distance between the two points detected first is a X directional length A minimum and maximum values for the length detected in whole scanning lines following the same procedure are set If you do not want to allow the unit to search a...

Page 89: ... detection direction X Direct T X inspection object color Black OUT T BLACK Detectable images Undetectable images Reasons Only the part having no inspection color less than 5 pixels and the value less than the minimum value for inspection object is captured 82 ...

Page 90: ...value for which teaching was executed allowable limit Example Settings of teaching and judgement criteria If the color of the inspection object black and detection direction X OK judgement NG judgement Cannot detect the color of the inspection object The inpsection length is beyond a base length value allowable range Since the color of the inspection object is black the maximum minimum values for ...

Page 91: ...f which a length is measured The unit detects only the parts more than the minimum value for inspection object Page 87 5 Run a teaching In TEACHING mode In the TEACHING mode register edge direction and distance at the same time set the exposure time or range for measuring area inspection area and area for setting extraction color Page 88 6 Set judgement criteria In JUDGEMENT CRITERIA SETTING mode ...

Page 92: ...the 6 button for approximately three seconds SAVE CANCEL SAVE SAVE function Saves the current settings If you want to save the settings select SAVE and press the 6 button for approximately three seconds TEACH OK OKNG Teaching OK only OK NG Allows you to select whether you want to execute a teaching for OK products only or both OK product and NG product B L PTN ON OFF10 OFF30 OFF60 Backlight Patter...

Page 93: ...automatically performs continuous inspections When OFF it performs an inspection every time trigger signal input INI T 1 7 Initial Type The selected product type number when the LightPixAE20 is turned on available only for colored areas SPEED High Middle Low Speed Allows you to select the processing time of measurement DIRC T Both DX DY Direction Type Allows you to select a direction in which leng...

Page 94: ...REMENTOBJECT MIN SETTING mode SET is displayed Referring the value saved when executing a teaching RMinX Min in the X direction RMaxX Max in the X direction RMinY Min in the Y direction RMaxY Max in the Y direction Allowable range to be set PMinX Min in the X direction PMaxX Max in the X direction PMinY Min in the Y direction PMaxY Max in the Y direction The 8 button Increases the value The 7 butt...

Page 95: ...r OK and NG products When performing a teaching the allowable limit for the distance set in JUDGEMENT CRITERIA SETTING mode is automatically set but the distance varies depending on the type of teaching See the table below Type Allowable range to be set automatically Teaching for OK product only Edge distance when executing a teaching 5 Teaching for OK and NG products When the limit for NG product...

Page 96: ... a teaching at this point press 6 first and then 1 SIZE Resizes the inspection If you want to execute a teaching at this point press 6 first and then 1 after resizing MOVE Moves inspection area 6 Executes a teaching for the current product type Teaching for the current product type is executed DONE Indicates successful completion of teaching FAIL Abnormal termination of teaching The ALARM signal i...

Page 97: ...t product type Executes a teaching for OK product of the current product type STNG Teaching for OK products Normal completion FAIL Abnormal termination of teaching The ALARM signal is output 6 Executes a teaching Executes a teaching for NG product of the current product type DONE Teaching for NG product Normal completion FAIL Failed to complete teaching The ALARM signal is output 5 Returns to the ...

Page 98: ...ges the width Y direction length The 7 button Reduces the length The 8 button Enlarges the length The inspection area is displayed in blue MOVE Movement of inspection area position The 3 button Moves the inspection area to the left The 4 button Moves the inspection area to the right The 8 button Moves the inspection area up The 7 button Moves the inspection area down 91 ...

Page 99: ... during teaching RMinX Min in the X direction RMaxX Max in the X direction RMinY Min in the Y direction RMaxY Max in the Y direction Allowable range to be set PMinX Min in the X direction PMaxX Max in the X direction PMinY Min in the Y direction PMaxY Max in the Y direction The 8 button Increases the value The 7 button Decreases the value MinX Min for Measurement Object in the X direction The 8 bu...

Page 100: ...ernal trigger OFF After switching to RUN mode input the TRIGGER signal to external devices or press the TRIGGER button Judged measurement results The LightPixAE20 outputs these judgement results to parallel ports of OUT1 to OUT3 Judgement results OUT3 OUT2 OUT1 All OK Both maximum and minimum are within the base length value for judgement base criteria OFF ON ON MAX OK Only maximum value is within...

Page 101: ...The unit failed to detect any length the display on the display is as the figure shown right Calculation time Up to two digits including the numbers under the decimal point If the detection direction is set to either X or Y the measurement data for unselected direction are not displayed Product type switch The 3 4 and 5 buttons Change the product types Once you switch the product types the outputs...

Page 102: ...ys turns off Never turns on OFF10 Turns off after 10 minutes OFF30 Turns off after 30 minutes OFF60 Turns off after 60 minutes All L ON OF ON OFF LED On Off Allows you to select whether or not to use a built in LED light ON The built in LED emits per inspection execution OFF The built in LED does not emit Please separately install lighting equipment for image processing All A SAVE ON OFF Auto Save...

Page 103: ...htPixAE20 by changing the speed in the following order Low Middle High Every time you change the speed the computation time is also changed Speed for each application is as the table shown below Unit ms High Middle Low Color Jdgement 20 50 150 Color Pattern 100 200 500 Edge Detection 10 15 20 Measurement 15 20 30 If you set Speed to Middle or High the unit scans the 352 pixels horizontal x 288 pix...

Page 104: ...direction in which lengths are measured Both Lengths are measured in both X and Y directions DX Lengths are measured only in the X horizontal direction DY Lengths are measured only in the Y vertical direction Measurem ent OUT T Black White Selects a color of inspection object Allows you to select a color black or white of the part for measurement Measurement is executed using a binary image so you...

Page 105: ...ilarity at the second step decreases by the setting value Detailed conditions DETAL Available only if the Detail function is set to ON The Revise function is used for detecting an image having more than the degree of similarity 0 100 from which the value set here was subtracted Refer to the pages describing Color Pattern Matching for more details Color Pattern Matching CAND1 1 50 Candidate1 Number...

Page 106: ...Section 5 Parallel Communication 99 ...

Page 107: ...Teaching Switches modes and executes a teaching TEACH signal TRIGGER signal 5 1 2 Output Signals from the LightPix The data output from the LightPixAE20 when executing a reading operation After executing an inspection the following signals are output to the parallel ports of OUT1 to OUT3 The output signals differ depending on the application and result Colro Area Judgment Results OUT3 OUT2 OUT1 OK...

Page 108: ... but X and Y position distance is out of range OFF OFF ON No images having more than the specified degree of similarity are detected OFF OFF OFF Edge Detection Judgement Result OUT3 OUT2 OUT1 OK Within the base position judgement criteria setting value OFF OFF ON NG Except those above OFF OFF OFF Peak Detection Judgement Result OUT3 OUT2 OUT1 OK Both X and Y distances are within the base position ...

Page 109: ...32C communication using external devices or to establish USB communication AETOOL When the READY signal is off the LightPixAE20 begins a reading operation If capture delay time CAP D has been set images arecaptured in the setting time after TRIGGER signal recognition When the product types are switched the first reading time T3 becomes 50ms longer than the second or later reading time 3 The LightP...

Page 110: ...ch between RUN VIEW mode and TEACHING mode To switch between TEACHING mode and RUN RUN VIEW mode The operation modes are switched only by changing the TEACH signal as the table shown below To switch between TEACHING mode and RUN RUN VIEW mode TEACH ON OFF READING mode RUN RUN VIEW mode Only turning the signals on off switches product types and operation modes The status of signals TEACH and TYPE 1...

Page 111: ...lowing time period Used inspection application Time period of T3 Color Area Color Judgement Color Pattern Matching 750 ms or longer Edge detection Peak Measurement 350 ms or longer The READY signal is turned off and a teaching is executed ADJ is displayed on the operation unit After the teaching is completed the READY signal is turned on If the unit failed to complete the teaching the ALARM signal...

Page 112: ...r Pattern Matching 750 ms or longer Edge Detection Peak Measurement 350 ms or longer 4 After capturing the NG product confirm that the READY signal is ON and then input the TRIGGER signal Time period of T3 is the same as that used for step 3 After the READY signal is turned off the unit executes a teaching for NG product When the teaching was completed the READY signal is turned on If the unit fai...

Page 113: ...Section 6 RS 232C Communication 107 ...

Page 114: ...n Speed 1200 2400 4800 9600 19200 38400 57600 bit s initial value 9600 Selectable in CONFIGURATION mode Transmission Code ASCII Bit Length 8 bits Stop Bit 1 bit Parity No Flow Control No BCC Yes Transmission Format Terminal code C R 0DH Command Command Code Description Data Area Read RD Reads the specified data area Data Area Write WD Write the value the specified data area This also enables you t...

Page 115: ...o of the LightPixAE20 receiving the command message and sending the response message are shown respectively Command 23H Indicates a command message Response Normal 24H Indicates a normal response message Response Error 21H Indicates a response message when an error occurred Text Error code 2 digit hexadecimal 00 FF Displays the details of the error when it occurred Block Check code 2 digit hexadec...

Page 116: ...ters BCC x 16 1 x 16 0 x 16 3 x 16 2 C R Low High x 16 1 x 16 0 Fixed If normal response is a double word type and consists of actual numbers Contents of the register Four characters Low Contents of the register head Four characters High Sender Station No R D x 16 5 x 16 4 x 16 7 x 16 6 x 16 1 x 16 0 x 16 3 x 16 2 or x 10 1 x 10 0 Fixed Low High Low High Contents of the register head Four characte...

Page 117: ...register head Four characters Low Contents of the register head Four characters High Sender Station No W D D x 16 5 x 16 4 x 16 7 x 16 6 x 16 1 x 16 0 x 16 3 x 16 2 or x 10 1 x 10 0 Fixed Low High Low High Contents of the register terminal Four characters Low Contents of the register terminal Four characters High BCC x 16 5 x 16 4 x 16 7 x 16 6 x 16 1 x 16 0 x 16 3 x 16 2 C R Low High Low High x 1...

Page 118: ...acters x 104 x 100 x 103 x 102 x 101 ASCII characters Just specify 02100 as decimal data Hexadecimal Data x 16 n Hexadecimal data Condition System Description Integer data 200 is specified Writing data Four characters C 8 0 0 ASCII characters Low High Data format used for WD command is as follows Writing data Four characters x 161 x 160 x 163 x 162 ASCII characters Low High If the condition data 2...

Page 119: ...hexadecimal numbering system In WD command a number out of the range specified by each command Eg 0 or a value more than 8 was specified as initial product type 61H DATA In WD command when specifying start end point and min max by using the command only one time for example if the start point in the area to be changed the preset end point these values should be reversed When moving the area and ch...

Page 120: ...in two modes Communication mode RUN RUN VIEW mode TEACHING mode No communication mode CONFIGURATION mode JDGEMENT CRITERIA SETTING mode Readable and writable items differ depending on the communication mode Yes in the table below indicates that the LightPixAE20 can read and write the items Mode Type of item RUN RUN VIEW TEACHING Inspection start Yes No LOCK Yes No Inspection Others Yes Yes CONFIGU...

Page 121: ...during communication ON When Internal trigger is on the READY signal turns off immediately after the READY signal restoration so it is difficult to send and receive data at the specified READY signal ON time Try to sent a command from external devices to the LightPixAE20 every about 50 ms several times until the external devices receive a response from the LightPixAE20 resulting in increasing poss...

Page 122: ...t type Inspection start WD 1500 1 Starts an inspection READY RD 1600 0 1 ALARM RD 1601 0 1 LOCK RD WD 1602 0 1 1 ON 0 OFF Mode RD WD 1603 0 4 0 RUN mode 1 RUN VIEW mode 2 TEACH mode 3 CONFIGURATION mode support for RD 4 JUDGEMENT CRITERIA SETTING mode support for RD OUT1 RD 1604 0 1 OUT2 RD 1605 0 1 INSPECTION OUT3 RD 1606 0 1 1 ON 0 OFF 2100 Product type 1 2101 Product type 2 2102 Product type 3 ...

Page 123: ...tput 2400 Product type 1 X coordinate at upper left 2401 Product type 1 X coordinate at lower right 2403 Product type 1 Y coordinate at lower right 2404 2407 Product type 2 X coordinate at upper left Y coordinate at lower right 2408 2411 Product type 3 X coordinate at upper left Y coordinate at lower right 2412 2415 Product type 4 X coordinate at upper left Y coordinate at lower right 2416 2419 Pr...

Page 124: ... ON 1 OFF Backlight Pattern RD WD 4900 0 3 0 ON 1 OFF10 2 OFF30 3 OFF60 CONFIGURA TION Auto Save RD WD 5000 0 1 0 ON the Auto Save function is activated 1 OFF the Auto Save function is canceled RD WD 5100 5127 0 101376 Area value the number of pixels Product type 1 Max 5100 5101 Min 5102 5103 Product type 2 Max 5104 5105 Min 5106 5107 Product type 3 Max 5108 5109 Min 5110 5111 Product type 4 Max 5...

Page 125: ...2 Product Type3 2103 Product Type4 2104 Product Type 5 2105 Product Type 6 Exposure Time Setting RD WD 2106 0003 5000 Product Type7 WD Used for running a teaching in data area 2500 using 1 without exposure time adjustment RD Reads the current exposure time 2200 Product type 1 X coordinate at upper left 2201 Product type 1 Y coordinate at upper left 2202 Product type 1 X coordinate at lower right 2...

Page 126: ... 1 2700 Product type 1 X coordinate at upper left 2701 Product type 1 Y coordinate at upper left 2702 Product type 1 X coordinate at lower right 2703 Product type 1 Y coordinate at lower right 2704 2707 Product type 2 X coordinate at upper left Y coordinate at lower right 2708 2711 Product type 3 X coordinate at upper left Y coordinate at lower right 2712 2715 Product type 4 X coordinate at upper ...

Page 127: ...109 Product type 6 X 5110 Y 5111 Product type 7 X 5112 Y 5113 Allowable range mm RD WD 5114 5141 Depends on the type of unit Actual values and double word type Product type 1 X 5114 5115 Y 5116 5117 Product type 2 X 5118 5119 Y 5120 5121 Product type 3 X 5122 5123 Y 5124 5125 Product type 4 X 5126 5127 Y 5128 5129 Product type 5 X 5130 5131 Y 5132 5133 Product type 6 X 5134 5135 Y 5136 5137 Produc...

Page 128: ...pe 2 2102 Product Type 3 2103 Product Type 4 2104 Product Type 5 2105 Product Type 6 Exposure Time Setting RD WD 2106 0003 5000 Product Type 7 WD Used for running a teaching in data area 2500 using 1 without exposure time adjustment RD Reads the current exposure time 2200 Product Type 1 X coordinate at upper left 2201 Product Type 1 Y coordinate at upper left 2202 Product Type 1 X coordinate at lo...

Page 129: ...1 3 1 Low 2 Middle 3 High Available only for Color Judgement Initial Product Type RD WD 3200 1 7 1 7 Internal Trigger RD WD 3300 0 1 0 ON 1 OFF Capture Delay RD WD 3400 0 160 0 160 Output Delay RD WD 3500 0 160 0 160 Baud Rate RD WD 3600 96 576 RS 232C Communication Speed 96 144 192 384 576 Station No RD WD 3700 1 99 1 99 RD WD 3800 0 1 0 ON 1 OFF WD 3900 1 Type of Teaching RD WD 4100 0 1 0 OK 1 O...

Page 130: ...e 1 X 5114 5115 Y 5116 5117 Product type 2 X 5118 5119 Y 5120 5121 Product type 6 X 5134 5135 Y 5136 5137 Product type 7 X 5138 5139 Y 5140 5141 Base Position Distance The number of pixels Product type 7 X 5212 Y 5213 RD 5200 5113 X 0 357 Y 0 288 Product type 1 X 5200 Y 5201 Product type 2 X 5202 Y 5203 Product type 3 X 5204 Y 5205 Product type 4 X 5206 Y 5207 Product type 5 X 5208 Y 5209 Product ...

Page 131: ...1606 0 1 1 ON 0 OFF 2100 Product type1 2101 Product type2 2102 Product type3 2103 Product type4 2104 Product type5 2105 Product type6 RD WD 2106 0003 5000 Product type7 WD Used for running a teaching in data area 2500 using 1 without exposure time adjustment RD Reads the current exposure time 2200 Product type 1 X coordinate at upper left 2201 Product type 1 Y coordinate at upper left 2202 Product...

Page 132: ...1 Low 2 Middle 3 High Available only for Color Judgement Initial Product Type RD WD 3200 1 7 1 7 Internal Trigger RD WD 3300 0 1 0 ON 1 OFF Capture Delay RD WD 3400 0 160 0 160 Output Delay RD WD 3500 0 160 0 160 Baud Rate RD WD 3600 96 576 RS 232C Communication Speed 96 144 192 384 576 Station No RD WD 3700 1 99 1 99 LED On Off RD WD 3800 0 1 0 ON 1 OFF Initial Setting WD 3900 1 Type of Teaching ...

Page 133: ...5128 5129 Product type 5 X 5130 5131 Y 5132 5133 Product type 6 X 5134 5135 Y 5136 5137 Product type 7 X 5138 5139 Y 5140 5141 Base Position the number of pixels RD 5200 5113 X 0 357 Y 0 288 Product type1 X 5200 Y 5201 Product type 2 X 5202 Y 5203 Product type 3 X 5204 Y 5205 Product type 4 X 5206 Y 5207 Product type 5 X 5208 Y 5209 Product type 6 X 5210 Y 5211 Product type 7 X 5212 Y 5213 JUDGEME...

Page 134: ...ON OUT3 RD 1606 0 1 1 ON 0 OFF 2100 Product type1 2101 Product type2 2102 Product type3 2103 Product type4 2104 Product type5 Product type 6 Exposure Setting Time RD WD 2106 0003 5000 Product type 7 WD Used for running a teaching in data area 2500 using 1 without exposure time adjustment RD Reads the current exposure time 2200 Product type 1 X coordinate at upper left 2201 Product type 1 Y coordin...

Page 135: ...rnal Trigger RD WD 3300 0 1 0 ON 1 OFF Capture Delay RD WD 3400 0 160 0 160 Output Delay RD WD 3500 0 160 0 160 RD WD 3600 96 576 RS 232C Communication Speed 96 144 192 384 576 Station No RD WD 3700 1 99 1 99 LED On Off RD WD 3800 0 1 0 ON 1 OFF Initial Setting WD 3900 1 Type of Teaching RD WD 0 OK 1 OK NG 4100 0 1 Save Image Condition RD WD 4200 0 2 0 OFF 1 All Images 2 NG Image Only Teaching Tri...

Page 136: ...5240 5241 Inspection object min value the number of pixels RD WD 5300 5313 X 0 357 Y 0 288 Product Type 1 X 5300 Y 5301 Product Type 2 X 5302 Y 5303 Product Type 3 X 5304 Y 5305 Product Type 4 X 5306 Y 5307 Product Type 5 X 5308 Y 5309 Product Type 6 X 5310 Y 5311 Product Type 7 X 5312 Y 5313 Inspection object min value mm RD WD 5314 5341 Depends on the type of unit Actual values and double word t...

Page 137: ...pends on the type of unit Actual values and double word type Product Type 1 X 5514 5515 Y 5516 5517 Product Type 2 X 5518 5519 Y 5520 5521 Product Type 3 X 5522 5523 Y 5524 5525 Product Type 4 X 5526 5527 Y 5528 5529 Product Type 5 X 5530 5531 Y 5532 5533 Product Type 6 X 5534 5535 Y 5536 5537 Product Type 7 X 5538 5539 Y 5540 5541 Com 131 ...

Page 138: ...Section 7 About AETOOL and GT11 133 ...

Page 139: ...playing operation status The LightPixAE20 can executes all of the operations you can perform with both the operation unit and the finder unit Documenting configuration data Writes out the backup configuration data in the CSV format The followings listed below are included in the AETOOL AETOOL software for displaying operation status of the LightPixAE20 or the settings AETOOL Help Sytem Transfer us...

Page 140: ...Jpn exe downloaded from our website After an installation dialog appears on the monitor install following the message When selecting Panasonic MEW Vision LightPixAE20 from the Windows start menu you see About USB driver on the monitor Read the descriptions on the installation of a USB driver and follow the instruction for your OS to install Refer to AETOOL Help for details of operation instruction...

Page 141: ...me 0 sec Since the LightPixAE20 does not receive any serial RS 232C commands while capturing images it may ignore transmissions from the GT11 Therefore increase the retry time up to the upper limit and set waiting time to 0 sec so that the GT11 can execute retries one after another in this case the device executes retries every about 50 ms But even if the waiting time is set to 0 sec the LightPixA...

Page 142: ...nal cable ANE2803 or ANE2823 to connect the LightPixAE20 to the GT11 Connecting to the GT11 with the RS 232C connection cable ANE2803 Wiring with three cables for RS232C Cable color Signal Yellow SD Red RD Black SG Example connection with the GT11 137 ...

Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...

Page 144: ...oving a barrister and condenser from the primary side of the built in power supply unit Cut off current 10mA 2 Examined with USB cable removed and water proof cap attached Main unit Item Specification ANE2010 ANE2020 ANE2030 Installation distance mm 15 0 5 45 2 5 55 5 170 140 to 220 View range mm 2 x 1 6 10 x 8 30 x 25 80 x 70 70 x 56 to 100 x 80 Resolution 0 02 0 1 0 3 0 5 Light sensitive element...

Page 145: ...ain unit Max communication distance 10m without a finder unit 3m with a finder unit Finder unit Item Specification Display 2 inch color LCD display Backlight White LED Service live of backlight 40 000h operating temperature 25ºC Optional cables ANE2803 ANE2813 ANE2823 Item Specification Connection ANE2803 Main unit RS 232C port ANE2813 Main unit operation unit ANE2823 Main unit RS232C port and ope...

Page 146: ...t ANE11 Finder unit ANE12 The operation unit comes with the items below Mounting frame for operation unit 1 Installation instruction 1 The finder unit comes with the items below Operation unit with a mounting frame for finder unit 1 Installation instruction 1 Cables Product name Product number RS 232C communication cable length 3m Main unit external device ANE2803 Connection cable 3m Main unit ope...

Page 147: ...8 3 Dimensions Main Unit ANE2000 Main Unit ANE2010 ANE2020 ANE2030 A Capturing part B LED lamp C Power I O cable approx 3m D USB connector E Connector for optional cable 143 ...

Page 148: ...Mounting plate Operation unit 144 ...

Page 149: ...Finder unit 145 ...

Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...

Page 151: ...ARCT1F406E 200505 P 2005 ...

Reviews: