background image

LC2H

Product types

1. Panel mounting type

1) One-touch installation type

1

 Standard type

Note) Please ask us about types without front resetting.

2

 Backlight type

DIN HALF SIZE 

LCD COUNTER

LC2H 

Counters

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz/30 Hz switchable

Yes

Non-voltage input type

LC2H-FE-2KK

Voltage input type (4.5 to 30 V DC)

LC2H-FE-DL-2KK

30 Hz

Free voltage input type (24 to 240 V AC/DC)

LC2H-FE-FV-30

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz/30 Hz switchable

Yes

Voltage input type (4.5 to 30 V DC)

LC2H-FE-DL-2KK-B

Panel mounting type

One-touch installation type

Panel mounting type

Installation frame type

PC board mounting type

Features

1. 8.7 mm 

.343 inch

 Character Height 

(previously 7 mm)

Easy-to-read character height increased 
from 7 mm to 8.7 mm 

.276 inch to .343 

inch

.

2. Plenty of Digits

3. Counting Speed Switchable 
between 2 kHz and 30 Hz
4. Panel Mounting Type Features 
2 Installation Methods

Comes with very easy one-touch 
installation type and also installation 
frame type that uses the bracket on the 
timer/counter. Choose a method that 
suits the application.

5. Battery Replacement Easy on 
Environment

To replace battery simply remove body 
for the one-touch installation type, and 
remove battery lid for the installation 
frame type.

6. Screw Terminals Designed for 
Safety

Built in finger protection.

7. Panel Covers Replacable

(Standard color is ash gray.)
Change the panel design by replacing 
with a black panel cover.

8. Conforms to IP66 Protective 
Construction (Only installation frame 
type.) (Front panel surface)
9. Input Methods

1) Non-voltage input method
2) Voltage input method
3) Free voltage input method

10. Backlight Type Added to Series 
and Now 2-color Switchable (green/
red)

Easy viewing even in dark places and 
switchable between green and red 
(Voltage input type).

11. Compliant with UL, c-UL and CE.

RoHS Directive compatibility information

http://www.nais-e.com/

8.7mm

.343inch

8 digits

Product chart

Type

Installation type

Standard type

Backlight type

Non-voltage input type

Voltage input type

(4.5 to 30 V DC)

Free voltage input type

(24 to 240 V AC/DC)

Voltage input type

(4.5 to 30 V DC)

Panel 
mounting 
type

One-touch installation type

Installation frame type

PC board mounting type

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Summary of Contents for LC4H-PS-R6-AC240V

Page 1: ...at uses the bracket on the timer counter Choose a method that suits the application 5 Battery Replacement Easy on Environment To replace battery simply remove body for the one touch installation type and remove battery lid for the installation frame type 6 Screw Terminals Designed for Safety Built in finger protection 7 Panel Covers Replacable Standard color is ash gray Change the panel design by ...

Page 2: ... Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contacts or open collector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Approx 4 7 kΩ Residual volta...

Page 3: ... 1 1 0 25 ms 16 7 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual voltage Max 0 5 V Reset input Min input signal width 10 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual power Max 0 5 V Break down volta...

Page 4: ...nput Lock switch Unit display 1 Count speed switch Unit display 2 Count speed switch Lock switch RESET COUNTER LC2H Front reset button Terminal block side LCD side OFF ON Terminal block side LCD side 2k Hz 30Hz Fixed at 30 Hz Dimensions 1 Panel mounting type External dimensions 1 One touch installation type mm inch General tolerance 1 0 039 Panel installation diagram Note When installing to a 4 5 ...

Page 5: ...the mounting frame ATH3803 and the rubber packing ATH3804 Only installation frame type For connected installation sealed installation Only installation frame type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofing will be lost when installing repeatedly sealed installation 45 1 772 0 5 0 020 0 22 2 874 0 5 0 020 0 60 min 2 362 min 22 2 874 0 5 0 020 0 A 48...

Page 6: ... type Contact input Transistor input NPN transistor PNP transistor 2 PC board mounting type External dimensions Terminal layout and wiring diagrams General tolerance 1 0 039 mm inch PC board pattern BOTTOM VIEW General tolerance 0 1 004 Note The AXS212811K is recommended as a compatible connection socket LC2H COUNTER 33 02 0 3 1 300 012 43 4 1 709 17 3 681 DIP switch 8 19 748 15 24 0 3 600 012 3 3...

Page 7: ...unt input 1 2 3 4 5 6 0V 0V Reset input Count input 1 2 3 4 V V 5 6 1 2 3 4 5 6 Reset input Count input V V 1 2 3 4 Green Red 24V DC 24V DC 5 6 1 2 3 4 5 6 1 Counting takes place when the count input signal is ON 2 Counting resumes again when the count value reaches 99999999 full scale value and then returns to 0 with a new count input 3 No measurement takes place when a reset is input 1 When rese...

Page 8: ...ctions might occur if the floating capacitance of these wires exceeds 500 pF 10 m 32 808 ft for parallel wires of 2 mm2 3 Free voltage input type 1 Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non voltage input 2 Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal and the application of volta...

Reviews: