background image

Model

KX-A272

Operating Instructions

DECT Repeater

Please read before use and save.

QUQX00130YA_01_A  20/1/04  6:40 pm  Page 1

Summary of Contents for KX-A272

Page 1: ...Model KX A272 Operating Instructions DECT Repeater Please read before use and save ...

Page 2: ...ironment 4 Accessories 4 Wall Mounting 5 Connection 5 Placement 6 LED Status 6 Automatic Registration 7 Manual Registration 8 De Registration 10 Verification Tone 11 Site Survey Mode 12 Serial Repeater ID Programming 13 Before Requesting Help 15 Technical Information 16 Guarantee 17 Index 18 ...

Page 3: ...ith TDA PBX products plus TD1232 TD816 with TD7590 a software upgrade may be necessary Designed to be used as a range extender no handover using TD7580 Designed to be used as a range extender no handover using TD7590 without the software upgrade General Safety Only use the power supply included with the product Do not connect the AC adaptor to any AC outlet other than the standard AC220 240V The a...

Page 4: ...han 40ºC The AC adaptor is used as the main disconnect device Ensure that the AC outlet is located near the unit and is accessible WARNING TO PREVENT THE RISK OF ELECTRICAL SHOCK DO NOT EXPOSE THE PRODUCT TO RAIN OR ANY OTHER TYPE OF MOISTURE Accessories Included AC Adaptor PQLV19E UK only PQLV19AL Australian or PQLV19CE European Repeater KX A272 Quick Setup Guide QUQX00112Y Operating Instructions...

Page 5: ...n of 2mm from the base of the screw head to the wall using the washer provided see diagram below Arrange the AC cord as shown then mount the unit 4 possible routes available Connection Plug in the AC adaptor to the rear of the unit and fasten the AC cord to prevent it from being disconnected The AC adaptor must remain connected at all times It is normal for the adaptor to feel warm during use LED ...

Page 6: ...ashes move the repeater closer to the Base Unit Cell Station or away from obstructions etc LED Status Red LED Indicates special states Green LED Indicates registration communications states On off blink specification Definition On Repeater is not assigned to any system Off Normal Operation Slow blinking 320ms on 320ms off Manual registration mode Intermittent blinking 100ms on 2 4sec off Verificat...

Page 7: ...ll light for 2 seconds and then the green LED will flash slowly This indicates that the repeater is searching for the cell station or base unit When the repeater has found the cell station or base unit the green LED will go steady ON Note It may take up to 60 seconds for the repeater to register with the cell station or base unit If after 60 seconds the registration has not completed the red LED w...

Page 8: ... and then the green LED will flash slowly Hold down the repeater switch for 3 seconds The green LED and the red LED will flash alternately Place your DECT base unit into registration mode by pressing and holding the Ï Ï button for 10 seconds This step is not necessary for registration to PBX cell stations When the repeater has found a suitable cell station or base unit the green LED will flash qui...

Page 9: ...h 10 times i e digits 025 will cause the green LED to flash 10 times for 0 then a delay of 2 seconds then flash 2 times for 2 then a delay of 2 seconds then flash 5 times for 5 You do not have to wait for the confirmation flashes when registering Dial on the handset to store the identifying number to memory The green LED will go off for 1 second If the identifying number entered is already assigne...

Page 10: ... off disconnect the AC adaptor both LEDs are OFF While holding down the repeater switch power on the repeater by connecting the AC adaptor Continue to hold down the repeater switch for 10 seconds The red LED will flash slowly After 10 seconds the red LED will go steady ON The Repeater is now de registered successfully To re register the repeater please follow the normal registration process ...

Page 11: ... and the green LED is steady ON To activate a verification tone press and hold the switch for one second The green LED and the red LED will flash alternately with the red LED synchronised with the verification tone sounding on the handset To return the repeater to normal mode and disable the verification tone press the repeater switch a second time The green LED will go steady ON and the red LED w...

Page 12: ...ch the required number of times i e twice for channel 2 The default site survey channel is 1 The red LED will flash the number of times corresponding with the channel selected The channel between 0 and 9 can be selected by pressing the switch the corresponding number of times channel 0 10 times At channel 9 one switch press will change the channel back to 0 Site survey mode is now operational To t...

Page 13: ...o chain level 1 when first registered to a cell station After registration the chain level may be changed to a different chain level Additional repeaters can be registered to operate on the same chain level this will allow star configurations on each chain level All repeaters and cell stations must have a unique Radio Part Number R P N There can be 6 repeaters per chain level Chain level 1 and cha...

Page 14: ...ust be brought into close range with the repeater already set to chain level 2 Press the switch the corresponding number of times to set the chain level i e 3 times chain level 3 etc The red LED flashes a number of times corresponding to the chain level NB Pressing the switch 4 or more times corresponds to chain level 1 After two minutes from power ON the new chain level and Radio Fixed Part Ident...

Page 15: ...ication tone on Switch off verification tone Poor audio quality Out of range of base Move repeater closer to base unit Cell Station Out of range of handset Move handset closer to repeater A ringing call Delay when moving from Answer the call before moving suddenly stops cell station to repeater beyond repeater cell station when moving from during incoming ring boundary zone to zone in group ring m...

Page 16: ...it rate 1152 kbit s Modulation GFSK RF Transmission Power Approx 250mW Voice Coding ADPCM 32kbit s Operating Range Up to 300m outdoors line of sight Up to 50m indoors Power Source AC Adaptor 220 240V AC 50 60Hz Power Consumption 4 6 VA Operating Conditions 5ºC 40ºC 20 80 relative air humidity Dimensions 140mm x 140mm x 37mm AC adaptor cord length 1 5m Specifications are subject to change The illus...

Page 17: ...use in an improper manner or inconsistent with the technical and or safety standards required in the country where this appliance is used or to damage occurred during transit to or from the purchaser 4 If at any time during the guarantee period any part or parts of the appliance are replaced with a part or parts not supplied or approved by us or of an objective quality safe and suitable for the ap...

Page 18: ...ing Help 15 Compatibility 3 Connection 5 De Registration 10 Environment 4 General Safety 3 Guarantee 17 Index 18 LED Status 6 Manual Registration 8 Overview 3 Placement 6 Serial Repeater ID Programming 13 Site Survey Mode 12 Technical Information 16 Verification Tone 11 Wall Mounting 5 ...

Page 19: ...Operating Instructions 19 ...

Page 20: ...ble at the following web address http doc panasonic de 0436 1999 5 EC Technical specifications are subject to change Sales Department Panasonic Business Systems U K Panasonic House Willoughby Road Bracknell Berkshire RG12 8FP Panasonic Communications Company U K Ltd Pencarn Way Duffryn Newport South Wales NP10 8YE United Kingdom Printed in the United Kingdom QUQX00130YA KU1203AP0104AP1 For your fu...