background image

2022.

7

High-frequency AC Method

*

 

The contents of this catalog are as of 

October 2017

.

For the latest information, please visit our company website.

Thin Type Ionizer

ER-VW

Summary of Contents for ER-VW

Page 1: ...2022 7 High frequency AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Thin Type Ionizer ER VW ...

Page 2: ...ct up to a maximum of 5 ER VW units The air supply part is connected via quick connection joints and the power supply and input output signals can also be connected easily using connection cables with connectors at both ends Multiple ER VW units can be connected together to provide charge removal layouts that suit the target equipment End connector Accessory Cable with connector Accessory Air supp...

Page 3: ...jacent production lines MOUNTING SIZE Comparison of air consumption Notes 1 Minimum width dimensions after nozzle angle adjustment 2 Maximum width dimensions after nozzle angle adjustment ER VW Previous spot type Minimum 100 ℓ min ANR to Maximum 300 ℓ min ANR Air consumption ℓ min ANR 300 200 100 0 Minimum 15 ℓ min ANR Maximum 60 ℓ min ANR to In contrast to previous low frequency types and DC type...

Page 4: ...arge Air supply Discharge halt Ionizer main unit One each of connector attached cable length 0 5 m 1 640 ft end connector and lead wire for connecting F G are supplied with the ionizer main unit Type Appearance Charge removal time 1 000 V 100 V Ion balance Model No Spot type 1 sec or less Note 1 10 V or less Note 1 ER VW Note 2 Notes 1 A typical sample applied with a supply voltage of 24 V a dista...

Page 5: ...tput and 0 V Residual voltage 1 V or less at 50 mA sink current Output operation Check output CHECK ON when the discharge needle is dirty or worn OFF when operation is normal Error output ERROR OFF when abnormal discharge is detected ON when operation is normal Discharge output DSC Note 5 ON when discharging OFF when discharge halts Short circuit protection Incorporated Discharge halt input DSC OF...

Page 6: ...harge plate monitor At center of CPM Air flow Correlation between charge removal distance and ion balance Correlation between charge removal distance and charge removal time Charge removal field 0 50 MPa Connector terminal arrangement Power I O connector Joint connector 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 1 Non voltage contact or NPN open collector transistor or Discharge halt input Low 0 V Discharg...

Page 7: ...ins 1 and 3 of the end connector 9 pin to the lead wire for connecting the F G If the ground is not connected correctly operating problems or accidents may occur so be sure to check the usage conditions and connect the ground in such a way that the power supply does not become shorted Nozzle M4 pan head screw Purchase separately Adjusting the air blowing direction After screw down the nozzle to lo...

Page 8: ...o this product should be limited in length to less than 10 m 32 808 ft When this product is no longer usable or required dispose of properly as industrial waste Always be sure that the power supply and the air supply are both turned off before inspection and cleaning Be sure to turn off the air before removing the nozzles for purposes such as maintenance Air pressure may cause the discharge needle...

Page 9: ...3 ø4 5 ø0 177 mounting holes 16 3 0 642 2 0 079 16 9 0 665 4 8 0 189 40 1 575 110 4 331 80 3 150 7 0 276 60 2 362 15 3 0 602 127 5 000 Plug with hexagonal hole Joint for ø6 mm ø0 236 in air tube 42 1 654 2 ø14 4 ø0 567 DIMENSIONS Unit mm in The CAD data can be downloaded from our website ...

Page 10: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Reviews: