Thank you very much for purchasing Panasonic products. Please 
read this Instruction Manual carefully and thoroughly for the 
correct and optimum use of this product. Kindly keep this manual 
in a convenient place for quick reference.

SPECIFICATIONS

1

Indicators

12 to 24V DC      %  Ripple P-P 10% or less

+10
-15

Item
Type of pressure

Model No.

DP-M2

DP-M2A

Type

Standard

With analog current output

50mA or less

75mA or less

Differential pressure

Rated pressure range

0 to 2.00 kPa.D {0 to 204 mmH

2

O.D}

Hysteresis

0.01 kPa.D {1mm H

2

O.D}

Repeatability

Within 

s

1% F.S.

Displayable 
pressure range

-0.05 to 2.10 kPa.D {-5 to 210 mmH

2

O.D}

Operation

Orange LED (lights up when the comparative output is ON)

Pressure unit

Red LED (The indicator corresponding to the selected unit 
lights up during the sensing mode.)

M1 setting

Red LED (blinks in the M1 setting mode)

M2 setting

Red LED (blinks in the M2 setting mode)

Response time

10ms or less

Short-circuit protection

Incorporated

Set pressure range

0 to 2.00 kPa.D {0 to 204 mmH

2

O.D}

Setting resolution

0.01 kPa.D {1 mmH

2

O.D}

Pressure withstandability

6 kPa.D {612 mmH

2

O.D}

Applicable fluid

Non-corrosive gas

Display

3 digit red LED display (Sampling rate: 4 times/sec. approx.)

Comparative output

NPN open-collector transistor

Maximum sink current: 100mA

Applied voltage: 30V DC or less

(between comparative output and 0V)

Residual voltage: 1V or less (at 100mA sink current)

0.4V or less (at 16mA sink current)

Output operation

Supply voltage

Ambient temperature

0 to +50

Υ

 (No dew condensation), Storage: -10 to +60

Υ

Ambient humidity

35 to 85% RH, Storage: 35 to 85% RH

Pressure port

ȭ

4.6mm resin pipe

Weight

75g approx.

Temperature characteristics

Over ambient temperature range 0 to +50

Υ

:

within 

s

3% F.S. of detected pressure at 25

Υ

Material

Front case: ABS, Rear case: ABS
LED display: Acrylic, Pressure port: PA

Cable

0.18mm

2

 3-core oil resistant 

cabtyre cable, 2m long

0.18mm

2

 4-core oil resistant 

cabtyre cable, 2m long

Current consumption

Analog current output

Selectable either Normally open (NO) or Normally closed 
(NC) by the keys.

Refer to '

ࠉࠉ

SETTING

' [

Output mode and output 

operation

] for more details.

8

Output current: 4 to 20mA

0 to 1.96 kPa.D
{0 to 200 mmH

2

O.D}

Zero-point: Within 4mA 

s

1% F.S.

Span: Within 16mA 

s

3% F.S.

Linearity: Within 

s

1% F.S.

Load resistance: 0 to 250

Ȑ

MJE-DPM No.0050-31V

PIPING

3

Recommended tube

Notes: 1) 

2) 

3) 

TYGON is registered trademarks of SAINT-GOBAIN.
Ensure that excessive pressure is not applied to the pressure ports. Since this 
sensor is designed for detecting small pressures, if excessive pressure or shock 
is applied to the pressure ports, the diaphragm (pressure sensing device) in the 
sensor may get damaged.
Please do not compress the tube. If the tube is compressed, pressure exceeding 
the rated value may be generated, damaging the diaphragm (pressure sensing 
device).

Pressure Hi-port

Fix tubes on ports securely

Pressure Lo-port

Flexible tubes
(silicone tube etc.)

TYGON   tube, size: internal dia 4mm, external dia 6mm, made 
by SAINT-GOBAIN.

Not good

ە

ە

Apply higher pressure to the Hi-port and lower pressure to the 
Lo-port.
Use flexible tubes (silicone tube etc.) that can fit the pressure 
ports, 

ȭ

4.6mm in diameter. The tubes should cover more than 

half the length of the pressure ports.

ە

ە

ە

Never use this product as a sensing device for 
personnel protection.
In case of using sensing devices for personnel protec-
tion, use products which meet laws and standards, 
such as OSHA, ANSI or IEC etc., for personnel 
protection applicable in each region or country.
In case this sensor is used within Japan, SI unit 
must be used since use of pressure units in Japan 
is restricted to SI units.

WARNING

CAUTIONS

2

ە

ە
ە
ە
ە
ە

ە

ە

ە

ە
ە

ە

ە
ە

ە

This product has been developed / produced for industrial use 
only.
Use within the rated pressure range.
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, 
ensure that the frame ground (F.G.) terminal of the power supply 
is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter 
motor, etc.) is used in the vicinity of this sensor, connect the 
frame ground (F.G.) terminal of the equipment to an actual 
ground.
Do not use during the initial transient time (0.5 sec.) after the 
power supply is switched on.
Do not run the wires together with high-voltage lines or power 
lines or put them in the same raceway. This can cause malfunc-
tion due to induction.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in contact with water, 
oil, grease, organic solvents, such as, thinner etc., or strong 
acid, and alkaline.
Do not insert wires, etc, into the pressure port. The diaphragm 
(pressure sensing device) will get damaged and correct opera-
tion shall not be maintained.
Do not operate the keys with pointed or sharp objects.
Make sure that stress by forcible bend or pulling is not applied 
directly to the sensor cable joint.
Extension up to total 100m is possible with 0.3mm

2

, or more, 

cable. However, in case of using this product as a CE conformity 
product, the power wire connected to this product must be within 
10m.

DP-M

 series is designed for use with non-corrosive gas. It cannot 

be used for liquid or corrosive gas.

LED Display

Digital Differential Pressure Sensor

DP-M

 Series     

For use outside Japan

INSTRUCTION MANUAL

Summary of Contents for DP-M Series

Page 1: ...re sensing device in the sensor may get damaged Please do not compress the tube If the tube is compressed pressure exceeding the rated value may be generated damaging the diaphragm pressure sensing device Pressure Hi port Fix tubes on ports securely Pressure Lo port Flexible tubes silicone tube etc TYGON tube size internal dia 4mm external dia 6mm made by SAINT GOBAIN Not good ە ە Apply higher pre...

Page 2: ...or codes and key protection sign are displayed Pressure unit indicator mmH2O kPa Red յ The indicator of the selected unit lights up during the sensing mode Both indicators turns off during the initial setting mode and during an error occurrence The indicator of the selected unit blinks during the upper and lower threshold value setting mode ո ն The settable digit is shifted cyclically at every pre...

Page 3: ... Set Output operation Output mode and Unit Measurement Commence measurement on completion of setting Į Upper and lower threshold value setting Enter lower threshold value M1 upper threshold value M2 If key protect has been set make be to release key protect before operating the keys Please refer to KEY PROTECT FUNCTION for the procedure 9 Set to sensing mode The sensor will automatically enter the...

Page 4: ...sensing mode after lower threshold value M1 and upper threshold value M2 have been set Since the values which have been set are stored in an EEPROM they are not erased even if the power supply is switched off Enter lower threshold value M1 The registered lower threshold value M1 appears and blinks The M1 setting indicator red and the pressure unit indicator red also blinks In the sensing mode pres...

Reviews: